HomeGeneral ElectricPACSystems RX3iEthernet interface moduleGeneral Electric IC695ETM001 PACSystems RX3i Ethernet Interface Module
General Electric•Ethernet interface module

General Electric IC695ETM001 PACSystems RX3i Ethernet Interface Module

Pricing
Request Pricing
Contact us for current price and availability.

The General Electric IC695ETM001 is an Ethernet interface module for the PACSystems RX3i series. This module provides two 10/100 Mbps Ethernet communication ports with auto-negotiation capabilities. It occupies a single slot across compatible RX3i universal backplanes. The unit features an internal 200 MHz communications processor. It facilitates communication between RX3i controllers and platforms like Series 90 and VersaMax systems.

ManufacturerGeneral Electric
Part NumberIC695ETM001
Product TypeEthernet interface module
ConditionNew
Warranty12 Months
AvailabilityRequest current stock
12-Month Warranty30-Day Return Request WindowGlobal Shipping Support
✓
12 Months WarrantyCommercial warranty confirmed with quotation.
↩
30-Day Return RequestEligible returns subject to authorization.
✈
Worldwide ShippingCourier and freight options for international orders.
#
Part Number VerificationSend a label photo when suffix or revision is uncertain.
PRODUCT INFORMATION

Product Overview

The General Electric IC695ETM001 is an Ethernet interface module for the PACSystems RX3i series. This module provides two 10/100 Mbps Ethernet communication ports with auto-negotiation capabilities. It occupies a single slot across compatible RX3i universal backplanes. The unit features an internal 200 MHz communications processor. It facilitates communication between RX3i controllers and platforms like Series 90 and VersaMax systems.

The module executes communication protocols over a four-layer TCP/IP network stack. Supported protocols include Service Request Transport Protocol, Modbus TCP, and Ethernet Global Data. It acts as both a Modbus TCP client and a Modbus TCP server. System time can synchronize to an SNTP time server over Ethernet. Hot insertion and removal are supported when the controller operates with compatible firmware versions.

TECHNICAL DATA

Technical Specifications

ParameterSpecification
Weight1.13 lbs (0.51 kg)
CompatibilityPACSystems RX3i
Ethernet Ports2x 10/100 Mbps
Serial RS-232Yes
Serial Data Rates1200 bps to 115200 bps
Hot-swappableYes
Autosensing PortsYes
Ethernet Processor speed200 MHz
Non-volatile memoryYes – Allows daisy-chaining of Ethernet nodes
Transmission Rate10/100 Mbps
Ethernet Connectors8-pin female shielded RJ45
Serial Connector9-pin female D-connector
Duplex ModesHalf and full duplex
TECHNICAL INFORMATION

Features

  • Provides two 10/100 Mbps autosensing Ethernet ports using shielded 8-pin RJ45 connectors.
  • Features an internal 200 MHz processor for dedicated communications handling.
  • Includes an RS-232 serial port offering baud rates from 1200 to 115200 bps.
  • Supports Ethernet Global Data, Modbus TCP client and server, and SRTP communication protocols.
  • Enables network time synchronization using Simple Network Time Protocol services.
  • Allows hot-swap insertion and removal under system power with appropriate firmware.
  • Includes front-panel LED indicators for Ethernet status, LAN status, and individual port links.
TECHNICAL INFORMATION

Applications

  • Plant-wide communication between PACSystems RX3i controllers and legacy Series 90 or VersaMax platforms.
  • Distributed control networks requiring deterministic data transfer using Ethernet Global Data exchange.
  • Industrial Modbus TCP supervisory integration connecting field devices, PLCs, and SCADA systems.
TECHNICAL INFORMATION

Connections / Interfaces

  • Two 8-pin female shielded RJ45 ports supporting 10/100Base-T Ethernet cabling.
  • One 9-pin female D-sub connector providing RS-232 serial communication.
  • Serial port supports Station Manager access for diagnostics, monitoring, and supervisory control.
TECHNICAL INFORMATION

Installation Guidelines

  1. Install into an unpowered PACSystems RX3i backplane slot during routine system maintenance.
  2. Hot-swap module insertion under power requires PACSystems RX3i firmware revision 2.51 or higher.
  3. Firmware upgrades are supported in the field using official vendor programming tools.
TECHNICAL INFORMATION

Configuration Guidelines

  1. Configure Ethernet port speed, duplex mode, and crossover settings through PACSystems programming software.
  2. Use the built-in Station Manager for supervisory diagnostic polling, logs, and password administration.
TECHNICAL INFORMATION

Compatibility

  • Compatible with PACSystems RX3i backplane models IC695CHS007, IC695CHS012, and IC695CHS016.
  • Functions with standard RX3i central processing units except for the CPE400 controller model.
  • Integrates with existing Series 90 and VersaMax hardware through supported network protocols.
COMPATIBILITY

Compatibility & Replacement

COMPATIBLE MODELSCompatible with PACSystems RX3i backplane models IC695CHS007, IC695CHS012, and IC695CHS016. Functions with standard RX3i central processing units except for the CPE400 controller model. Integrates with existing Series 90 and VersaMax hardware through supported network protocols.

Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.

PART VERIFICATION

Before You Order

Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.

01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS

From RFQ to Dispatch

1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ

Frequently Asked Questions

What backplanes support the General Electric IC695ETM001?
The IC695ETM001 operates in IC695CHS007, IC695CHS012, and IC695CHS016 PACSystems RX3i backplanes. It occupies a single universal backplane slot.
Does the IC695ETM001 support hot-swapping?
Yes, the IC695ETM001 supports hot-swap insertion and removal under power. The controller requires firmware revision 2.51 or higher to use this capability.
Which industrial communication protocols are supported on this module?
The module supports Modbus TCP client/server, Ethernet Global Data, and SRTP protocols. It also supports time synchronization using SNTP.
What RX3i controller model is incompatible with the IC695ETM001?
The IC695ETM001 is compatible with PACSystems RX3i controllers, except for the CPE400 processor model.
Condition Confirmed Before OrderQuoted condition is confirmed before payment and dispatch.
Warranty & Returns12 Months standard warranty and 30-day return request period.International DeliveryShipping method is selected according to destination and shipment size.
Technical Source PolicySpecifications are published only when supported by product or manufacturer references.
NEED THIS PART?

IC695ETM001

Send the quantity and destination country. We will confirm stock, condition, price and lead time.

Get Product Updates and Stock Availability Alerts

    REQUEST A QUOTE

    Check Price & Availability

    ProductGeneral Electric IC695ETM001 PACSystems RX3i Ethernet Interface Module
    Part Number: IC695ETM001

      Request a Quote

      Send us the required quantity and destination. We will reply with current availability, lead time and final pricing.

      Home
      Products
      Account