PRODUCT INFORMATION
Product Overview
The General Electric IC200ALG264 is a PLCs/Machine Control module for the VersaMax I/O platform. It provides 15 single-ended current input channels arranged in a single group. Each channel accepts 0 to 20 mA or 4 to 20 mA signals. Individual analog-to-digital converters deliver 15-bit resolution across all active inputs. The unit mounts directly onto a VersaMax carrier base.
This module consumes up to 100 mA from the 5 VDC backplane power supply. Field transmitters require an external power supply to operate. An on-board OK LED confirms normal backplane power and proper configuration. Diagnostic routines detect field power loss. The unit also reports open-wire faults during 4 to 20 mA operation.
TECHNICAL DATA
Technical Specifications
| Parameter | Specification |
|---|
| Weight | 1.00 lbs (0.45 kg) |
|---|
| Product Description | 15-Point Analog current input module |
|---|
| Channels | 15 single ended, one group |
|---|
| No of Channels | 15, single-ended inputs |
|---|
| Wiring configuration | Single-ended |
|---|
| Isolation | 250VAC continuous; 1500VAC for 1 minute |
|---|
| No. of groups | 1 group |
|---|
| Input signal, nominal | 0-20 mA; 4-20 mA |
|---|
| LED Indicators | Yes OK LED |
|---|
| Compatible signals | 4 to 20 mA / 0 to 20 mA |
|---|
| Analog resolution | 15 bits |
|---|
| Backplane Current Consumption | 5V: 100 mA maximum |
|---|
| Resolution | 15 bit |
|---|
| Digital resolution | 0.5 µA for 4-20 mA; 0.625 µA for 0-20 mA |
|---|
| Diagnostics | Yes |
|---|
| External Supply Voltage Range | None |
|---|
| Input impedance | 100 Ohms |
|---|
| Input Currents | 1 to 20 mA |
|---|
| Internal Supply Voltage | 5 VDC from PLC backplane |
|---|
| Filter response (3dB Corner Freq) | 24 Hz +/-20% |
|---|
| Backplane current | 100 mA |
|---|
| Update rate | 7.5 ms, maximum |
|---|
| Accuracy | 0.3% typical, 1% maximum |
|---|
| Input signal selection | No terminal jumper installed: 4-20 mA With Jumper installed: 0-20 mA |
|---|
| Resolution at 4-20 mA | 0.5µA |
|---|
| Current Draw | 100 mA, maximum |
|---|
| Resolution at 0-20 mA | 0.625µA |
|---|
| Input grouping | Single group |
|---|
| Module width | Single slot |
|---|
TECHNICAL INFORMATION
Features
- Provides 15 single-ended current inputs organized into a single group.
- Supports configurable current ranges of 0 to 20 mA and 4 to 20 mA.
- Dedicated analog-to-digital converters offer 15-bit conversion resolution on each channel.
- Features maximum update speed of 7.5 milliseconds across channels.
- Detects open-wire conditions during 4 to 20 mA operation.
- Monitors field-side power loss and reports faults to the controller.
- Operates with 100 mA maximum current draw from the 5 VDC backplane.
TECHNICAL INFORMATION
Applications
- Current loop monitoring in distributed control applications.
- Interface for industrial process transmitters measuring flow, level, or pressure.
- Data acquisition within VersaMax PLC remote I/O stations.
TECHNICAL INFORMATION
Connections / Interfaces
- Single-ended wiring configuration with common return across all 15 channels.
- Terminal jumpers select between 0 to 20 mA and 4 to 20 mA ranges.
- Backplane interface draws 5 VDC internal operating power.
TECHNICAL INFORMATION
Installation Guidelines
- Insert the module into a compatible VersaMax I/O carrier.
- Disconnect backplane power prior to inserting or removing the unit.
- Provide external operating power for all connected current transmitters.
TECHNICAL INFORMATION
Configuration Guidelines
- Leave terminal jumpers uninstalled to select the default 4 to 20 mA range.
- Install terminal jumpers on designated pins to select the 0 to 20 mA range.
- Verify that the green OK LED illuminates after downloading controller configuration.
- Configure diagnostic reporting in supervisory software for open-wire and power fault monitoring.
TECHNICAL INFORMATION
Compatibility
- Integrates with General Electric VersaMax PLC CPUs and Network Interface Units.
- Installs on compatible VersaMax snap-on I/O carrier bases.
COMPATIBILITY
Compatibility & Replacement
COMPATIBLE MODELSIntegrates with General Electric VersaMax PLC CPUs and Network Interface Units. Installs on compatible VersaMax snap-on I/O carrier bases.
Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.
PART VERIFICATION
Before You Order
Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.
01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS
From RFQ to Dispatch
1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ
Frequently Asked Questions
How is the input range selected on the IC200ALG264?
Terminal jumpers determine the input range. Remove jumpers for 4-20 mA or install them for 0-20 mA operation.
What diagnostic capabilities does the General Electric IC200ALG264 provide?
It detects field power loss. It also identifies open-wire conditions when configured for 4-20 mA operation.
Does the IC200ALG264 module offer channel-to-channel isolation?
No channel-to-channel isolation is provided. All 15 channels reside in a single group sharing common reference.
What is the market reference price for the IC200ALG264?
Observed prices range from $1,094.11 to $2,247.18. These figures are indicative market reference pricing only and are not a final quotation.