PRODUCT INFORMATION
Product Overview
The General Electric IC670CBL002 is an Input/Output Expansion Cable designed for the Field Control series. It connects an Input/Output terminal block to a Bus Interface Unit terminal block. The cable assembly spans 21 inches or 54.61 centimeters in length. A keyed connector prevents incorrect orientation during mating. Internal wiring utilizes a 20-pin arrangement for signal path continuity.
This expansion cable carries voltage ratings of 115 Volts AC or 24 Volts DC. It functions across power frequencies from 50 to 60 Hertz. The outer sheath is made of polyvinyl chloride for physical protection. A braided drain wire connects to the chassis for electrostatic discharge protection. The cable operates without electrical derating at altitudes up to 1,000 meters.
TECHNICAL DATA
Technical Specifications
| Parameter | Specification |
|---|
| Weight | 0.31 lbs (0.14 kg) |
|---|
| UPC | 0 799705793231 |
|---|
| Connector Design | Keyed connector |
|---|
| General Application | Connecting Input/Output terminal block to Bus Interface Unit terminal block |
|---|
| Number of Cables Required for Every Field Control Station | 1 cable |
|---|
| Operating Frequency | 50 to 60 Hertz |
|---|
| Wire Design | Braided drain wire grounded or connected to chassis for electrostatic protection |
|---|
| Cable Length | 21 inches (54.61 centimeters) |
|---|
| Voltage Rating | 115 Volts AC or 24 Volts DC |
|---|
| Installation Altitude | Up to 1,000 meters (3,300 feet) without derating |
|---|
| Sheath Material | Polyvinyl chloride |
|---|
| Number of Pins | 20 pins |
|---|
TECHNICAL INFORMATION
Features
- Measures 21 inches (54.61 centimeters) in length for station expansion.
- Equipped with a 20-pin keyed connector for proper mating.
- Operates at voltage ratings of 115 Volts AC or 24 Volts DC.
- Features a polyvinyl chloride jacket for mechanical durability.
- Includes a braided drain wire providing electrostatic grounding to chassis.
- Functions up to 1,000 meters altitude without electrical derating.
TECHNICAL INFORMATION
Applications
- Interconnection between Field Control Bus Interface Unit terminal blocks and I/O terminal blocks.
- Expansion of local I/O stations within industrial automation enclosures.
TECHNICAL INFORMATION
Connections / Interfaces
- 20-pin keyed connector for terminal block interfaces.
- Integrated braided drain wire for grounding to chassis.
TECHNICAL INFORMATION
Installation Guidelines
- Install one IC670CBL002 cable per Field Control station configuration.
- Align the keyed connector body carefully before seating the connection.
- Ground the braided drain wire to the chassis for electrostatic protection.
- Ensure installation remains within the 1,000-meter altitude limit to prevent derating.
TECHNICAL INFORMATION
Compatibility
- General Electric Field Control I/O terminal blocks.
- General Electric Field Control Bus Interface Unit terminal blocks.
COMPATIBILITY
Compatibility & Replacement
COMPATIBLE MODELSGeneral Electric Field Control I/O terminal blocks. General Electric Field Control Bus Interface Unit terminal blocks.
Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.
PART VERIFICATION
Before You Order
Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.
01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS
From RFQ to Dispatch
1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ
Frequently Asked Questions
What is the function of the IC670CBL002 cable?
The IC670CBL002 connects an Input/Output terminal block to a Bus Interface Unit terminal block.
What voltage ratings are supported by the IC670CBL002?
The cable supports operating voltage ratings of 115 Volts AC or 24 Volts DC.
How many IC670CBL002 cables are needed for each Field Control station?
Each Field Control station installation requires one IC670CBL002 expansion cable.
What electrostatic protection is built into the IC670CBL002?
The cable includes a braided drain wire that connects to the chassis for grounding.