HomeGeneral ElectricPACSystems RX3iHigh-Speed Counter ModuleGeneral Electric IC694APU300 PACSystems RX3i High-speed Counter Module
General Electric•High-Speed Counter Module

General Electric IC694APU300 PACSystems RX3i High-speed Counter Module

Pricing
Request Pricing
Contact us for current price and availability.

The General Electric IC694APU300 is a PACSystems RX3i High-speed Counter Module for measurement applications. It operates on 250 mA or 1.25 watts sourced from the 5 V backplane bus. The module provides a maximum count rate of 1 MHz. Its operational duty cycle ranges from 25% to 87%. Input circuits support 12 positive logic single-ended lines or 6 differential lines. Off-state leakage current remains capped at 10 μA per point.

ManufacturerGeneral Electric
Part NumberIC694APU300
Product TypeHigh-Speed Counter Module
ConditionNew
Warranty12 Months
AvailabilityRequest current stock
12-Month Warranty30-Day Return Request WindowGlobal Shipping Support
✓
12 Months WarrantyCommercial warranty confirmed with quotation.
↩
30-Day Return RequestEligible returns subject to authorization.
✈
Worldwide ShippingCourier and freight options for international orders.
#
Part Number VerificationSend a label photo when suffix or revision is uncertain.
PRODUCT INFORMATION

Product Overview

The General Electric IC694APU300 is a PACSystems RX3i High-speed Counter Module for measurement applications. It operates on 250 mA or 1.25 watts sourced from the 5 V backplane bus. The module provides a maximum count rate of 1 MHz. Its operational duty cycle ranges from 25% to 87%. Input circuits support 12 positive logic single-ended lines or 6 differential lines. Off-state leakage current remains capped at 10 μA per point.

The IC694APU300 provides four positive logic outputs rated for up to 1.5 A resistive load. Output operating voltage spans 4.7 to 40 V DC. Overcurrent protection incorporates self-healing capability with an inrush threshold of 1.6 A. Reverse polarity protection prevents damage from reversed OUTPWR and OUTCOM wiring. Group-to-group isolation withstands 250 VAC continuous and 1500 VAC for one minute. The module supports CMOS load drive capability.

TECHNICAL DATA

Technical Specifications

ParameterSpecification
Weight1.50 lbs (0.68 kg)
Power Consumption250 mA (1.25 watts) from 5 V bus on the backplane
Number of Positive Logic Inputs12 (Single Ended) or 6 (Differential)
Maximum Count Rate1 MHz, (Duty Cycle 25% to 87%)
Off State Leakage Current10 μA maximum per point
Output Voltage Drop0.5 V @ 500 mA and 1.5 V @ 1.5 A
Inrush Current1.6A without ESCP tripping
CMOS Load Drive CapabilityYes, available
Positive Logic OutputsFour Outputs
Output ProtectionProtected from overcurrent (ESCP) with self-healing capability
Reverse Polarity ProtectionProtected from reverse wiring between OUTPWR and OUTCOM terminals
Input Voltage Range5 V dc (TSEL jumpered to INCOM) and 10 to 30 V dc (TSEL open)
Output Voltage Range4.7 to 40 V dc at 1.5A maximum resistive load, 0.5A maximum pilot
Group-to-group Isolation Voltage250 VAC continuous, 1500 VAC for one minute
TECHNICAL INFORMATION

Features

  • Processes pulse signals up to 1 MHz across a 25% to 87% duty cycle.
  • Supports 12 single-ended inputs or 6 differential positive logic inputs.
  • Includes selectable 5 V DC and 10 to 30 V DC input ranges.
  • Supplies four positive logic outputs rated up to 1.5 A each.
  • Provides self-healing overcurrent protection with 1.6 A inrush capability.
  • Features reverse polarity protection between OUTPWR and OUTCOM terminals.
  • Maintains group-to-group isolation of 250 VAC continuous and 1500 VAC transient.
TECHNICAL INFORMATION

Applications

  • High-speed pulse counting and frequency measurement in PACSystems RX3i systems.
  • Input signal processing from single-ended and differential pulse sources.
  • Direct control of external loads using four positive logic outputs.
TECHNICAL INFORMATION

Connections / Interfaces

  • Field input terminals support 12 single-ended inputs or 6 differential inputs.
  • TSEL jumper terminal selects between 5 V DC and 10 to 30 V DC input levels.
  • Four positive logic output points connect to loads up to 1.5 A.
  • OUTPWR and OUTCOM terminals accept external power with reverse polarity protection.
TECHNICAL INFORMATION

Installation Guidelines

  1. Seat the module firmly into a PACSystems RX3i system rack slot.
  2. Jumper TSEL to INCOM for 5 V DC input operation.
  3. Leave TSEL open when operating with 10 to 30 V DC input signals.
  4. Verify correct wiring polarity at OUTPWR and OUTCOM terminals before powering.
TECHNICAL INFORMATION

Configuration Guidelines

  1. Select between single-ended and differential input modes for connected signals.
  2. Ensure input pulse frequencies do not exceed the 1 MHz rating.
  3. Maintain input duty cycles within the specified 25% to 87% range.
TECHNICAL INFORMATION

Compatibility

  • PACSystems RX3i control systems.
  • Single-ended and differential pulse input sources.
  • CMOS load drive interfaces.
COMPATIBILITY

Compatibility & Replacement

COMPATIBLE MODELSPACSystems RX3i control systems. Single-ended and differential pulse input sources. CMOS load drive interfaces.

Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.

PART VERIFICATION

Before You Order

Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.

01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS

From RFQ to Dispatch

1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ

Frequently Asked Questions

What is the maximum counting frequency of the IC694APU300?
The module supports a maximum counting rate of 1 MHz with a 25% to 87% duty cycle.
What input configurations are supported by the IC694APU300 module?
It supports 12 single-ended positive logic inputs or 6 differential inputs.
How is the input voltage range configured on the IC694APU300?
Jumper TSEL to INCOM for 5 V DC. Leave TSEL open for 10 to 30 V DC.
What output protection mechanisms are included?
The module has self-healing overcurrent protection and reverse polarity protection between OUTPWR and OUTCOM terminals.
Condition Confirmed Before OrderQuoted condition is confirmed before payment and dispatch.
Warranty & Returns12 Months standard warranty and 30-day return request period.International DeliveryShipping method is selected according to destination and shipment size.
Technical Source PolicySpecifications are published only when supported by product or manufacturer references.
NEED THIS PART?

IC694APU300

Send the quantity and destination country. We will confirm stock, condition, price and lead time.

Get Product Updates and Stock Availability Alerts

    REQUEST A QUOTE

    Check Price & Availability

    ProductGeneral Electric IC694APU300 PACSystems RX3i High-speed Counter Module
    Part Number: IC694APU300

      Request a Quote

      Send us the required quantity and destination. We will reply with current availability, lead time and final pricing.

      Home
      Products
      Account