PRODUCT INFORMATION
Product Overview
The General Electric IC694APU300 is a PACSystems RX3i High-speed Counter Module for measurement applications. It operates on 250 mA or 1.25 watts sourced from the 5 V backplane bus. The module provides a maximum count rate of 1 MHz. Its operational duty cycle ranges from 25% to 87%. Input circuits support 12 positive logic single-ended lines or 6 differential lines. Off-state leakage current remains capped at 10 μA per point.
The IC694APU300 provides four positive logic outputs rated for up to 1.5 A resistive load. Output operating voltage spans 4.7 to 40 V DC. Overcurrent protection incorporates self-healing capability with an inrush threshold of 1.6 A. Reverse polarity protection prevents damage from reversed OUTPWR and OUTCOM wiring. Group-to-group isolation withstands 250 VAC continuous and 1500 VAC for one minute. The module supports CMOS load drive capability.
TECHNICAL DATA
Technical Specifications
| Parameter | Specification |
|---|
| Weight | 1.50 lbs (0.68 kg) |
|---|
| Power Consumption | 250 mA (1.25 watts) from 5 V bus on the backplane |
|---|
| Number of Positive Logic Inputs | 12 (Single Ended) or 6 (Differential) |
|---|
| Maximum Count Rate | 1 MHz, (Duty Cycle 25% to 87%) |
|---|
| Off State Leakage Current | 10 μA maximum per point |
|---|
| Output Voltage Drop | 0.5 V @ 500 mA and 1.5 V @ 1.5 A |
|---|
| Inrush Current | 1.6A without ESCP tripping |
|---|
| CMOS Load Drive Capability | Yes, available |
|---|
| Positive Logic Outputs | Four Outputs |
|---|
| Output Protection | Protected from overcurrent (ESCP) with self-healing capability |
|---|
| Reverse Polarity Protection | Protected from reverse wiring between OUTPWR and OUTCOM terminals |
|---|
| Input Voltage Range | 5 V dc (TSEL jumpered to INCOM) and 10 to 30 V dc (TSEL open) |
|---|
| Output Voltage Range | 4.7 to 40 V dc at 1.5A maximum resistive load, 0.5A maximum pilot |
|---|
| Group-to-group Isolation Voltage | 250 VAC continuous, 1500 VAC for one minute |
|---|
TECHNICAL INFORMATION
Features
- Processes pulse signals up to 1 MHz across a 25% to 87% duty cycle.
- Supports 12 single-ended inputs or 6 differential positive logic inputs.
- Includes selectable 5 V DC and 10 to 30 V DC input ranges.
- Supplies four positive logic outputs rated up to 1.5 A each.
- Provides self-healing overcurrent protection with 1.6 A inrush capability.
- Features reverse polarity protection between OUTPWR and OUTCOM terminals.
- Maintains group-to-group isolation of 250 VAC continuous and 1500 VAC transient.
TECHNICAL INFORMATION
Applications
- High-speed pulse counting and frequency measurement in PACSystems RX3i systems.
- Input signal processing from single-ended and differential pulse sources.
- Direct control of external loads using four positive logic outputs.
TECHNICAL INFORMATION
Connections / Interfaces
- Field input terminals support 12 single-ended inputs or 6 differential inputs.
- TSEL jumper terminal selects between 5 V DC and 10 to 30 V DC input levels.
- Four positive logic output points connect to loads up to 1.5 A.
- OUTPWR and OUTCOM terminals accept external power with reverse polarity protection.
TECHNICAL INFORMATION
Installation Guidelines
- Seat the module firmly into a PACSystems RX3i system rack slot.
- Jumper TSEL to INCOM for 5 V DC input operation.
- Leave TSEL open when operating with 10 to 30 V DC input signals.
- Verify correct wiring polarity at OUTPWR and OUTCOM terminals before powering.
TECHNICAL INFORMATION
Configuration Guidelines
- Select between single-ended and differential input modes for connected signals.
- Ensure input pulse frequencies do not exceed the 1 MHz rating.
- Maintain input duty cycles within the specified 25% to 87% range.
TECHNICAL INFORMATION
Compatibility
- PACSystems RX3i control systems.
- Single-ended and differential pulse input sources.
- CMOS load drive interfaces.
COMPATIBILITY
Compatibility & Replacement
COMPATIBLE MODELSPACSystems RX3i control systems. Single-ended and differential pulse input sources. CMOS load drive interfaces.
Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.
PART VERIFICATION
Before You Order
Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.
01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS
From RFQ to Dispatch
1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ
Frequently Asked Questions
What is the maximum counting frequency of the IC694APU300?
The module supports a maximum counting rate of 1 MHz with a 25% to 87% duty cycle.
What input configurations are supported by the IC694APU300 module?
It supports 12 single-ended positive logic inputs or 6 differential inputs.
How is the input voltage range configured on the IC694APU300?
Jumper TSEL to INCOM for 5 V DC. Leave TSEL open for 10 to 30 V DC.
What output protection mechanisms are included?
The module has self-healing overcurrent protection and reverse polarity protection between OUTPWR and OUTCOM terminals.