PRODUCT INFORMATION
Product Overview
The General Electric IC693MDL754 is a Series 90-30 Digital I/O module operating at 12 to 24 Volts DC. This unit provides 32 sourcing outputs organized into two isolated groups of 16 points. Each group possesses an independent common connection to switch positive-side field loads. Individual output points deliver up to 0.75 Amps of continuous current.
The module installs in General Electric Series 90-30 PLCs and PACSystems RX3i systems. Backplane power consumption requires 300 milliamps at 5 Volts DC bus voltage. Built-in electronic protection guards against overcurrent and short-circuit events with a 5-Amp trip threshold. Two rear DIP switches configure hardware settings and must match software definitions. The hardware operates in ambient temperatures between 32 and 140 degrees Fahrenheit.
TECHNICAL DATA
Technical Specifications
| Parameter | Specification |
|---|
| Weight | 1.13 lbs (0.51 kg) |
|---|
| Compatibility | GE Fanuc 90-30 PLCs |
|---|
| Output points | 32 |
|---|
| Output groups | 2 |
|---|
| Output point peak current | 0.75 Amps |
|---|
| Module current draw | 300 milliamps |
|---|
| Module voltage input | 5 Volts DC |
|---|
| Module configuration | DIP switch |
|---|
| Product Lifecycle Status* | Discontinued/Obsolete |
|---|
TECHNICAL INFORMATION
Features
- Provides 32 sourcing positive logic output points across two isolated groups.
- Delivers up to 0.75 Amps continuous load current per output point.
- Features electronic short-circuit and overcurrent protection on each output circuit.
- Allows 3 Amps inrush current surges without triggering an ESCP trip.
- Generates CPU fault signals upon power loss, ESCP failure, or DIP switch error.
- Draws 300 milliamps of current from the 5 Volts DC backplane bus.
TECHNICAL INFORMATION
Applications
- Drives separate DC field loads requiring up to 0.75 Amps continuous current.
- Controls isolated dual-group DC loads across Series 90-30 controller architectures.
- Provides discrete DC switching within PACSystems RX3i input and output racks.
TECHNICAL INFORMATION
Connections / Interfaces
- Provides two isolated groups of 16 sourcing outputs with independent commons.
- Features two configuration DIP switches located on the rear panel.
- Connects to external field power systems delivering 12 to 24 Volts DC.
TECHNICAL INFORMATION
Installation Guidelines
- Insert the module into any compatible Series 90-30 or PACSystems RX3i slot.
- Set the two rear DIP switches prior to module insertion.
- Maintain operating temperatures between 32 and 140 degrees Fahrenheit.
- Apply thermal derating above 104 degrees Fahrenheit when operating at 30 Volts DC.
- Store uninstalled modules between -40 and 185 degrees Fahrenheit.
TECHNICAL INFORMATION
Configuration Guidelines
- Set the rear DIP switches to match the rack software configuration.
- Mismatched DIP switch and software settings generate an active fault signal.
TECHNICAL INFORMATION
Compatibility
- Compatible with General Electric Series 90-30 programmable logic controllers.
- Compatible with PACSystems RX3i systems.
TECHNICAL INFORMATION
Lifecycle / Replacement Information
- The IC693MDL754 has reached discontinued and obsolete product lifecycle status.
COMPATIBILITY
Compatibility & Replacement
COMPATIBLE MODELSCompatible with General Electric Series 90-30 programmable logic controllers. Compatible with PACSystems RX3i systems.
Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.
PART VERIFICATION
Before You Order
Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.
01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS
From RFQ to Dispatch
1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ
Frequently Asked Questions
What is the continuous current rating of the IC693MDL754 outputs?
Each output point handles up to 0.75 Amps of continuous current. Inrush current reaches 3 Amps without tripping.
Which controller platforms accept the IC693MDL754 output module?
The module installs into General Electric Series 90-30 PLCs and PACSystems RX3i systems.
What operating events cause the module to generate a fault signal?
Faults trigger from field power loss, overcurrent trips, short circuits, or DIP switch mismatches.
What are the backplane power requirements for this module?
The module consumes 300 milliamps from the 5 Volts DC system backplane bus.