The Allen-Bradley 1746-NR8 SLC 500 Analog Input Module provides eight channels of RTD and resistance acquisition. It installs into a single chassis slot across SLC 500 fixed and modular hardware platforms. The unit derives operating power directly from the backplane without external power supplies. Power consumption reaches 1.82 W maximum, drawing 100 mA at 5 VDC and 55 mA at 24 VDC.

ManufacturerAllen-Bradley
Part Number1746-NR8
Product TypeAnalog Input Module
ConditionNew
Warranty12 Months
AvailabilityRequest current stock
12-Month Warranty30-Day Return Request WindowGlobal Shipping Support
✓
12 Months WarrantyCommercial warranty confirmed with quotation.
↩
30-Day Return RequestEligible returns subject to authorization.
✈
Worldwide ShippingCourier and freight options for international orders.
#
Part Number VerificationSend a label photo when suffix or revision is uncertain.
PRODUCT INFORMATION

Product Overview

The Allen-Bradley 1746-NR8 SLC 500 Analog Input Module provides eight channels of RTD and resistance acquisition. It installs into a single chassis slot across SLC 500 fixed and modular hardware platforms. The unit derives operating power directly from the backplane without external power supplies. Power consumption reaches 1.82 W maximum, drawing 100 mA at 5 VDC and 55 mA at 24 VDC.

The hardware performs analog-to-digital conversions through sigma-delta modulation. Automatic calibration executes at power-up and can run at five-minute intervals. Supported sensor types include platinum, copper, nickel, and nickel-iron resistance detectors. Direct resistance measurements range across 0 to 150, 500, 1000, and 300 Ohms. Front-panel LED indicators report channel operation and diagnostic status.

TECHNICAL DATA

Technical Specifications

ParameterSpecification
A/D Conversion methodSigma-delta modulation
Backplane Current100 mA @ 5VDC; 55 mA @ 24VDC
Backplane Current (24 Volts)55 milliamps
Backplane Current (5 Volts)100 milliamps
Backplane Power Consumption1.82W maximum (0.5W at 5V dc, 1.32W at 24V dc)
CategoryPLCs
Compatible RTD SensorsPlatinum (385) 100, 200, 500 and 1000; Platinum (3816) 100, 200, 500 and 1000; Copper (426) 10, Nickel (618) 120, Nickel (672) 120, and Nickel Iron (518) 604.
Compatible Resistance input range0 - 150 Ohms, 0 to 500 Ohms, 0 to 1000 Ohms and 0 to 300 Ohms
I/O Chassis locationAny slot except Slot 0
Inputs8
Module TypeRTD/Resistance Analog Input Module
No. if InputsEight (8)
Operating Temperature0 to 60 degrees Celsius
Operating Temperature Range32 to 140 degrees Fahrenheit
Resolution.01 Deg. Celcius
Step Response60 milliseconds in, 2.5 milliseconds out
Storage Temperature-40 to 85 degrees Celsius
UNSPSC32151705
UPC611320271720
Update Time6 milliseconds to 2 seconds
Weight0.69 lbs (0.31 kg)
TECHNICAL INFORMATION

Features

  • Accepts eight RTD or direct resistance input channels.
  • Employs sigma-delta analog-to-digital conversion.
  • Offers programmable input filters and a low-pass digital filter.
  • Features power-up autocalibration with programmable five-minute cycles.
  • Operates on backplane power without requiring an external supply.
TECHNICAL INFORMATION

Applications

  • Temperature monitoring using RTD sensor elements.
  • Mechanical displacement and travel measurement via resistance variation.
TECHNICAL INFORMATION

Connections / Interfaces

  • Compatible with the Allen-Bradley 1746-RT-35 removable terminal block.
  • Removable terminal block terminals accept single wire connections only.
  • Supports 2-wire, 3-wire, and 4-wire RTD sensor wiring configurations.
  • Recommended wiring for 2-wire RTDs is Belden 9501 shielded cable.
  • Recommended wiring for 3-wire and 4-wire RTDs is Belden 9533 or 83503.
TECHNICAL INFORMATION

Installation Guidelines

  1. Install the module into any chassis slot except Slot 0.
  2. Avoid long cable runs on 2-wire RTD circuits to preserve accuracy.
  3. Use heavier gauge wire such as AWG 16 to reduce wire resistance.
  4. Maintain continuous channel-to-channel isolation at 5 VDC.
TECHNICAL INFORMATION

Configuration Guidelines

  1. Configure digital filtering parameters to match process update needs.
  2. Update times range from 6 milliseconds to 2 seconds depending on settings.
  3. Set autocalibration cycles to run every 5 minutes during operation.
TECHNICAL INFORMATION

Compatibility

  • SLC 500 fixed chassis hardware.
  • SLC 500 modular chassis hardware.
  • Allen-Bradley 1746-RT-35 removable terminal block.
COMPATIBILITY

Compatibility & Replacement

COMPATIBLE MODELSSLC 500 fixed chassis hardware. SLC 500 modular chassis hardware. Allen-Bradley 1746-RT-35 removable terminal block.

Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.

PART VERIFICATION

Before You Order

Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.

01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS

From RFQ to Dispatch

1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ

Frequently Asked Questions

What chassis slots accommodate the 1746-NR8 module?
The module installs into any SLC 500 chassis slot except Slot 0.
Which RTD sensor types can connect to the 1746-NR8?
It accepts Platinum, Copper, Nickel, and Nickel-Iron RTDs. Direct resistance inputs are also supported.
Does the 1746-NR8 require an external power supply?
No external supply is needed. Backplane power provides 100 mA at 5 VDC and 55 mA at 24 VDC.
What terminal block connects field wiring to the 1746-NR8?
Field wiring connects using an Allen-Bradley 1746-RT-35 removable terminal block.
Condition Confirmed Before OrderQuoted condition is confirmed before payment and dispatch.
Warranty & Returns12 Months standard warranty and 30-day return request period.International DeliveryShipping method is selected according to destination and shipment size.
Technical Source PolicySpecifications are published only when supported by product or manufacturer references.
NEED THIS PART?

1746-NR8

Send the quantity and destination country. We will confirm stock, condition, price and lead time.

Get Product Updates and Stock Availability Alerts

    REQUEST A QUOTE

    Check Price & Availability

    ProductAllen-Bradley 1746-NR8 SLC 500 Analog Input Module
    Part Number: 1746-NR8

      Request a Quote

      Send us the required quantity and destination. We will reply with current availability, lead time and final pricing.

      Home
      Products
      Account