HomeAllen-BradleySLC 500Discrete output moduleAllen-Bradley 1746-OV16 SLC 500 Discrete Output Module
Allen-Bradley•Discrete output module

Allen-Bradley 1746-OV16 SLC 500 Discrete Output Module

Pricing
Request Pricing
Contact us for current price and availability.

The Allen-Bradley 1746-OV16 is a discrete output module designed for the SLC 500 modular system. It features sixteen sinking output channels arranged in a single common channel group. The unit operates within a voltage range of 10 to 50 VDC with 24 VDC nominal voltage. It energizes DC loads including relay coils, indicator lamps, and sounding devices. The module draws 0.270 A of backplane current at 5 VDC.

ManufacturerAllen-Bradley
Part Number1746-OV16
Product TypeDiscrete output module
ConditionNew
Warranty12 Months
Lifecycle StatusThe 1746-OV16 is part of the established Allen-Bradley SLC 500 hardware architecture. The removable terminal block simplifies maintenance operations within existing SLC 500 racks.
AvailabilityRequest current stock
12-Month Warranty30-Day Return Request WindowGlobal Shipping Support
✓
12 Months WarrantyCommercial warranty confirmed with quotation.
↩
30-Day Return RequestEligible returns subject to authorization.
✈
Worldwide ShippingCourier and freight options for international orders.
#
Part Number VerificationSend a label photo when suffix or revision is uncertain.
PRODUCT INFORMATION

Product Overview

The Allen-Bradley 1746-OV16 is a discrete output module designed for the SLC 500 modular system. It features sixteen sinking output channels arranged in a single common channel group. The unit operates within a voltage range of 10 to 50 VDC with 24 VDC nominal voltage. It energizes DC loads including relay coils, indicator lamps, and sounding devices. The module draws 0.270 A of backplane current at 5 VDC.

This single-slot module mounts directly into an SLC 500 modular chassis. A pre-installed removable terminal block allows field wiring to detach during maintenance. Continuous output current reaches 0.50 A per point at 30 °C and 0.25 A at 60 °C. Continuous current per module is 8.0 A at 30 °C and 4.0 A at 60 °C. Total module heat dissipation is 7.6 W, with 0.388 W dissipated per point.

TECHNICAL DATA

Technical Specifications

ParameterSpecification
ApplicationsHigh Current
Backplane Current (5 Volts)270 milliamps
Backplane current consumption0.270 A
CategoryPLCs
Continuous current per module8.0 A at 30 °C (86 °F); 4.0 A at 60 °C (140 °F)
Continuous current per point0.50 A at 30 °C (86 °F); 0.25 A at 60 °C (140 °F
Current/Module8 or 4 amps
Current/Output0.5 or 0.25 amps
GTIN10662468067031
Input Voltage Range10-50 VDC
Module TypeDiscrete output module
Nom Input Voltage24VDC
On-state voltage drop, max1.2V at 0.5 A
Outputs16
Signal delay, max. resistive loadOn = 0.1 ms; Off = 1.0 ms
Step Response60 milliseconds in, 2.5 milliseconds out
Surge current per point3.0 A for 10 ms
Voltage Range10-50 Volts DC Sink
Weight1.25 lbs (0.57 kg)
Wiring configurationSink wiring configuration
TECHNICAL INFORMATION

Features

  • Sixteen sinking DC output channels arranged in one common group.
  • Operating voltage range from 10 to 50 VDC with 24 VDC nominal operation.
  • Pre-installed removable terminal block enables rapid field wiring and replacement.
  • Fast signal delay with 0.1 ms turn-on and 1.0 ms turn-off resistive timing.
  • Surge current capacity of 3.0 A per point for 10 ms duration.
  • Low off-state leakage current of 1 mA and minimum load current of 1 mA.
TECHNICAL INFORMATION

Applications

  • Actuating direct-current relay coils and solenoid valves.
  • Illuminating DC indicator lamps and control console pilot lights.
  • Driving audible alarm sounders and signaling devices in industrial control panels.
TECHNICAL INFORMATION

Connections / Interfaces

  • The module provides a pre-installed removable terminal block for field wiring.
  • Field wiring connects sourcing DC loads referenced to the positive DC power supply.
  • All sixteen output points share a single common sinking return path.
  • The removable block allows hardware replacement without disturbing field wiring.
TECHNICAL INFORMATION

Installation Guidelines

  1. Install the hardware into any compatible single slot of a modular SLC 500 chassis.
  2. Disconnect chassis backplane power before inserting or extracting the module.
  3. Derate continuous current per point and per module when ambient temperature exceeds 30 °C.
TECHNICAL INFORMATION

Compatibility

  • Compatible with Allen-Bradley SLC 500 modular chassis systems.
  • Controls direct-current loads rated between 10 and 50 VDC.
TECHNICAL INFORMATION

Lifecycle / Replacement Information

  • The 1746-OV16 is part of the established Allen-Bradley SLC 500 hardware architecture.
  • The removable terminal block simplifies maintenance operations within existing SLC 500 racks.
COMPATIBILITY

Compatibility & Replacement

COMPATIBLE MODELSCompatible with Allen-Bradley SLC 500 modular chassis systems. Controls direct-current loads rated between 10 and 50 VDC.

Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.

PART VERIFICATION

Before You Order

Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.

01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS

From RFQ to Dispatch

1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ

Frequently Asked Questions

What circuit configuration does the Allen-Bradley 1746-OV16 output module use?
The 1746-OV16 uses a sinking DC transistor configuration across sixteen channels in a single common group.
What are the continuous current ratings for the 1746-OV16?
It provides 0.50 A per point at 30 °C and derates to 0.25 A per point at 60 °C.
Can field wiring remain intact during module replacement?
Yes. The pre-installed removable terminal block allows field wiring to detach without disconnecting individual leads.
Condition Confirmed Before OrderQuoted condition is confirmed before payment and dispatch.
Warranty & Returns12 Months standard warranty and 30-day return request period.International DeliveryShipping method is selected according to destination and shipment size.
Technical Source PolicySpecifications are published only when supported by product or manufacturer references.
NEED THIS PART?

1746-OV16

Send the quantity and destination country. We will confirm stock, condition, price and lead time.

Get Product Updates and Stock Availability Alerts

    REQUEST A QUOTE

    Check Price & Availability

    ProductAllen-Bradley 1746-OV16 SLC 500 Discrete Output Module
    Part Number: 1746-OV16

      Request a Quote

      Send us the required quantity and destination. We will reply with current availability, lead time and final pricing.

      Home
      Products
      Account