PRODUCT INFORMATION
Product Overview
The Allen-Bradley 5069-L3100ERMS3 is a safety controller in the CompactLogix system family. This unit provides ten megabytes of user application memory and five megabytes of dedicated safety memory. It complies with SIL 3 safety integrity level requirements for industrial automation applications. The unit supports up to thirty-one standard tasks and one dedicated safety task. Each configured task can execute up to one thousand programs using provided event triggers.
The controller mounts horizontally on compatible zinc-plated chromate steel DIN rails. It operates in ambient temperatures from 0 to 60 degrees Celsius. Non-volatile storage includes a two gigabyte SD card with expansion potential up to thirty-two gigabytes. Dual Ethernet ports support device level ring, star, and linear industrial network topologies. An external protective enclosure is recommended because the device has no built-in enclosure rating.
TECHNICAL DATA
Technical Specifications
| Parameter | Specification |
|---|
| Weight | 3.00 lbs (1.36 kg) |
|---|
| Module Type | Compact GuardLogix Controller |
|---|
| Application Memory | 10 Megabytes |
|---|
| Safety Memory | 5 MB |
|---|
| Non-volatile memory | 2GB via 1784-SD2 (ships with the controller) |
|---|
| No. of tasks | 31 Standard tasks; 1 Safety Task |
|---|
| SIL Rating | SIL 3 |
|---|
| Supported Ethernet/IP Network Topologies | Device Level Ring, Star, and Linear |
|---|
| Local I/O modules | 31 I/O modules |
|---|
| Communication Ports | 1 Type B 2.0 Full-Speed USB and 2 Ethernet/IP Ports |
|---|
| Communication rate, Ethernet | 10 Mbps / 100 Mbps / 1 Gbps |
|---|
| Communication rate, USB | 12 Mbps |
|---|
| Integrated Motion | Yes |
|---|
| Motion Axes, maximum | 256 Motion Axes |
|---|
| CIP drive axes | Thirty-Two (32) |
|---|
| Programming Languages | Sequential Function Chart, Function Block Diagram, Structured Text, and Ladder Diagram |
|---|
| Network Type | Ethernet |
|---|
| Supported Safety Tasks | 1 |
|---|
| Supported Standard Tasks | 31 |
|---|
| Programs per Task | 1000 |
|---|
| Operating Temperature | 32 to 140 degrees Fahrenheit |
|---|
| Storage Temperature | -40 to 185 degrees Fahrenheit |
|---|
TECHNICAL INFORMATION
Features
- SIL 3 safety integrity rating with 5 MB dedicated safety memory.
- Standard application user memory capacity of 10 MB.
- Support for 31 standard tasks and 1 safety task.
- Dual Ethernet ports supporting 10 Mbps, 100 Mbps, and 1 Gbps.
- Integrated motion capability supporting up to 32 CIP drive axes.
- Direct DIN rail mounting designed for horizontal cabinet installation.
TECHNICAL INFORMATION
Applications
- SIL 3 functional safety monitoring and machine protection circuits.
- Integrated multi-axis motion control across industrial Ethernet networks.
- Distributed standard and safety I/O automation architectures.
TECHNICAL INFORMATION
Connections / Interfaces
- One Type B 2.0 full-speed USB communication port operating at 12 Mbps.
- Two Ethernet/IP ports supporting 10 Mbps, 100 Mbps, and 1 Gbps rates.
- Local backplane connection supporting up to 31 local I/O modules.
TECHNICAL INFORMATION
Installation Guidelines
- Install the unit on an EN50022 35 by 7.5 millimeter DIN rail.
- Use zinc-plated chromate steel DIN rails to ensure proper conductivity and grounding.
- Mount the controller horizontally inside an external protective enclosure.
- Maintain ambient operating temperatures between 0 and 60 degrees Celsius.
- Ensure non-condensing relative humidity stays between 5 and 95 percent.
TECHNICAL INFORMATION
Configuration Guidelines
- Configure up to 31 standard tasks and 1 safety task.
- Assign up to 1000 programs per task using supported event triggers.
- Program using Ladder Diagram, Structured Text, Function Block, or Sequential Function Chart.
- Set up Ethernet communication in linear, star, or Device Level Ring topologies.
TECHNICAL INFORMATION
Compatibility
- Compatible with standard and safety 5069 series I/O modules.
- Connects to distributed standard and safety I/O architectures over Ethernet/IP.
- Supports 1784-SD2 non-volatile memory cards with expansion up to 32 GB.
TECHNICAL INFORMATION
Compliance and Certifications
- Meets SIL 3 functional safety requirements.
- Meets North American Temperature Code T4 rating.
- Rated for ATEX Temperature Code T4.
- Rated for IECEx Temperature Code T4.
COMPATIBILITY
Compatibility & Replacement
COMPATIBLE MODELSCompatible with standard and safety 5069 series I/O modules. Connects to distributed standard and safety I/O architectures over Ethernet/IP. Supports 1784-SD2 non-volatile memory cards with expansion up to 32 GB.
Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.
PART VERIFICATION
Before You Order
Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.
01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS
From RFQ to Dispatch
1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ
Frequently Asked Questions
What is the memory capacity of the Allen-Bradley 5069-L3100ERMS3?
The controller contains 10 MB of standard application memory and 5 MB of dedicated safety memory.
Which network topologies does the 5069-L3100ERMS3 support?
The controller supports Device Level Ring, linear, and star topologies across dual Ethernet ports.
What mounting orientation is required for this controller?
The controller supports horizontal mounting only on a compatible conductive DIN rail.
What safety rating does the 5069-L3100ERMS3 satisfy?
The controller meets SIL 3 functional safety requirements for industrial safety applications.