PRODUCT INFORMATION
Product Overview
The General Electric IC660BBD022 is a Genius I/O 24 V DC Source I/O Block. It operates as a stand-alone, single-node distributed station within the Genius I/O system. The unit provides sixteen discrete circuits that support sourcing field wiring connections. Each individual circuit operates on 24 VDC nominal power and accommodates either input or output configuration. The device interfaces directly with host controllers over the shielded twisted-pair Genius communication bus.
This open-type industrial block mounts on panels and requires a protective industrial enclosure. The hardware contains a terminal assembly and a plug-in electronics assembly. Diagnostic circuits actively detect overload, overtemperature, open wire, no-load, and failed switch events. Operators can perform local configuration and diagnostics via a Hand-Held Monitor connected to the terminal port. Remote configuration is also supported through host controller programming software.
TECHNICAL DATA
Technical Specifications
| Parameter | Specification |
|---|
| Weight | 3.44 lbs (1.56 kg) |
|---|
| Product Description | Source Block I/O |
|---|
| Circuits | 16 |
|---|
| No. of I/O | 16 |
|---|
| No. of circuits | 16 I/O circuits |
|---|
| Points per common | One group of 16 |
|---|
| Input signal voltage | 24 / 48 VDC |
|---|
| Load current | 2 Amperes |
|---|
| Operating voltage | 18-30VDC |
|---|
| Input processing time | 1.7 ms |
|---|
| Nominal voltage | 24VDC |
|---|
| Input diagnostics | Open wire, Overtemperature, Failed Switch |
|---|
| Heat dissipation | 68.8 Watts with 2 Amperes |
|---|
| Communication protocol | Genius Protocol |
|---|
| Output Current | 2 Amperes per circuit |
|---|
| Max. ripple | 10% |
|---|
| Input Response time | 1.7 msec plus configurable filter |
|---|
| maximum inrush current | 10 Amperes up to 10 ms |
|---|
| Output turn on deplay | 1 millisecond |
|---|
| Output response time | 1.0 msec |
|---|
| Maximum switching frequency | Once per second |
|---|
| Temperature | 0-60 degrees Celsius |
|---|
| Filter time | 5 to 100mS |
|---|
| Output diagnostics | Short Circuit, Overload, No Load, Failed Switch, Overtemperature |
|---|
| Block to Block Isolation | 1500V for one minute |
|---|
| Compatible Electronics assembly | IC660EBD021 |
|---|
| LEDs (I/O Block) | Unit OK, I/O Enabled |
|---|
| Compatible terminal base assembly | IC660TSD021 |
|---|
| Size (HxWxD) | 8.83" (22.44cm) x 3.50" (8.89cm) x 3.94" (10.00cm) |
|---|
| Operating Temperature | 0 Degree to 60 Degree Celsius |
|---|
| Storage temperature of | -40 Degree Celsius to 100 Degree Celsius |
|---|
| Humidity | 5-95% non-condensing |
|---|
TECHNICAL INFORMATION
Features
- Sixteen discrete circuits configurable individually as inputs or sourcing outputs.
- Genius bus communication supports daisy-chain network topology up to 7500 feet.
- Extensive hardware diagnostics detect short circuits, overloads, open circuits, and switch failures.
- Local configuration port supports connection of a Hand-Held Monitor.
- Selectable input filter times range from 5 to 100 milliseconds.
- Status indicators on front faceplate show Unit OK and I/O Enabled states.
TECHNICAL INFORMATION
Applications
- Distributed digital I/O processing on General Electric programmable automation networks.
- Interfacing 2-wire and 3-wire DC field sensors in industrial control cabinets.
- Direct switching of DC solenoids, indicators, and actuator devices up to 2 Amperes.
TECHNICAL INFORMATION
Connections / Interfaces
- Genius serial bus terminal connection for shielded twisted-pair industrial communication cables.
- Integrated monitor port on the terminal assembly for local Hand-Held Monitor interfacing.
- Sixteen field wiring terminals sharing one common group connection.
TECHNICAL INFORMATION
Installation Guidelines
- Mount the open-type unit upright in an enclosure protecting against airborne contaminants.
- Maintain ambient operating temperatures between 0 and 60 degrees Celsius.
- Ensure adequate spacing inside panels to dissipate up to 68.8 Watts under full load.
TECHNICAL INFORMATION
Configuration Guidelines
- Configure operating parameters locally using an optional Hand-Held Monitor.
- Adjust input filter times between 5 and 100 milliseconds to dampen electrical contact bounce.
- Set circuit assignments and pulse test functions via host PLC programming software.
TECHNICAL INFORMATION
Compatibility
- Communicates with General Electric PLC and PAC systems equipped with Genius Bus Controllers.
- Accepts field connections from standard 2-wire and 3-wire DC discrete sensors.
- Compatible with IC660EBD021 electronics assembly and IC660TSD021 terminal base assembly.
COMPATIBILITY
Compatibility & Replacement
COMPATIBLE MODELSCommunicates with General Electric PLC and PAC systems equipped with Genius Bus Controllers. Accepts field connections from standard 2-wire and 3-wire DC discrete sensors. Compatible with IC660EBD021 electronics assembly and IC660TSD021 terminal base assembly.
Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.
PART VERIFICATION
Before You Order
Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.
01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS
From RFQ to Dispatch
1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ
Frequently Asked Questions
What is the primary function of the GE IC660BBD022?
The IC660BBD022 provides sixteen configurable discrete 24 VDC sourcing I/O circuits on a Genius bus network.
How are field circuit faults diagnosed on this block?
The unit detects open wire, short circuit, overload, no-load, overtemperature, and failed switch conditions.
What is the maximum output current rating per circuit?
Each output circuit handles up to 2 Amperes of continuous load current with 1 millisecond turn-on delay.