HomeGeneral ElectricMark VI / Mark VIeTerminal Turbine BoardGeneral Electric IS200TTURH1CFD Mark VI / Mark VIe Terminal Turbine Board
General Electric•Terminal Turbine Board

General Electric IS200TTURH1CFD Mark VI / Mark VIe Terminal Turbine Board

Pricing
Request Pricing
Contact us for current price and availability.

The General Electric IS200TTURH1CFD is a Terminal Turbine Board for Mark VI and Mark VIe systems. It operates as a primary turbine protection input terminal board within turbine control architectures. The assembly interfaces with pulse rate devices sensing toothed wheels to track rotational speed. It also processes generator voltage and bus voltage inputs from external potential transformers. Turbine overspeed trip signals pass through this termi

ManufacturerGeneral Electric
Part NumberIS200TTURH1CFD
Product TypeTerminal Turbine Board
ConditionNew
Warranty12 Months
AvailabilityRequest current stock
12-Month Warranty30-Day Return Request WindowGlobal Shipping Support
✓
12 Months WarrantyCommercial warranty confirmed with quotation.
↩
30-Day Return RequestEligible returns subject to authorization.
✈
Worldwide ShippingCourier and freight options for international orders.
#
Part Number VerificationSend a label photo when suffix or revision is uncertain.
PRODUCT INFORMATION

Product Overview

The General Electric IS200TTURH1CFD is a Terminal Turbine Board for Mark VI and Mark VIe systems. It operates as a primary turbine protection input terminal board within turbine control architectures. The assembly interfaces with pulse rate devices sensing toothed wheels to track rotational speed. It also processes generator voltage and bus voltage inputs from external potential transformers. Turbine overspeed trip signals pass through this terminal board directly to designated trip boards.

Physical termination relies on two pluggable terminal blocks mounted to the primary circuit board. Two retaining screws secure each pluggable block to simplify routine field servicing. Each individual terminal block accepts twenty-four connections, providing forty-eight total termination points. A dedicated shield ground bar extends along the left edge of the printed circuit board. Factory-drilled mounting holes allow straightforward mechanical installation in standard cabinet positions. A protective conformal coating shields all surface-mount and through-hole components from environmental exposure.

TECHNICAL DATA

Technical Specifications

ParameterSpecification
PCB CoatingConformal Coating
TECHNICAL INFORMATION

Features

  • Two pluggable terminal blocks with twenty-four I/O termination points each.
  • Dedicated shield bar positioned along the left edge for signal grounding.
  • Supports speed monitoring inputs from pulse rate devices and TTL speed pickups.
  • Receives generator voltage and bus voltage inputs from potential transformers.
  • Routes turbine overspeed trip signals directly to the system trip board.
  • Conformal protective coating applied across the printed circuit assembly.
  • Factory-drilled holes allow secure screw-down chassis or panel mounting.
TECHNICAL INFORMATION

Applications

  • Primary turbine overspeed protection signal handling.
  • Turbine speed measurement using magnetic pulse and TTL pickups.
  • Generator and bus voltage potential transformer signal routing.
  • Mark VI and Mark VIe turbine control system I/O termination.
TECHNICAL INFORMATION

Connections / Interfaces

  • Two 24-point pluggable terminal blocks supporting 48 field wire connections.
  • Input terminations for pulse rate speed sensors and TTL pickups.
  • PT input channels for bus and generator voltage signals.
  • Output signal paths directing overspeed trips to the trip board.
  • Left-side grounding bar for field instrument cable shielding.
TECHNICAL INFORMATION

Installation Guidelines

  1. Mount the board using factory-drilled holes to secure the assembly.
  2. Fasten the two pluggable terminal blocks using two retention screws each.
  3. Terminate drain wires directly to the left-side shield ground bar.
  4. Verify that all 24 wire positions per block are seated properly.
TECHNICAL INFORMATION

Compatibility

  • General Electric Mark VI turbine control systems.
  • General Electric Mark VIe turbine control systems.
  • Compatible with TTUR primary turbine protection circuits.
COMPATIBILITY

Compatibility & Replacement

COMPATIBLE MODELSGeneral Electric Mark VI turbine control systems. General Electric Mark VIe turbine control systems. Compatible with TTUR primary turbine protection circuits.

Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.

PART VERIFICATION

Before You Order

Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.

01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS

From RFQ to Dispatch

1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ

Frequently Asked Questions

What is the primary function of the IS200TTURH1CFD terminal board?
The board routes turbine protection signals, including overspeed trips, generator voltages, and speed pickup inputs.
How many field connection points are available on the IS200TTURH1CFD?
The board provides 48 termination points divided across two 24-point pluggable terminal blocks.
Does the IS200TTURH1CFD include circuit protection for harsh environments?
Yes, the board features a conformal coating that protects the PCB from environmental contaminants.
What type of speed sensors connect to the IS200TTURH1CFD?
It connects to TTL speed pickups and pulse rate sensors monitoring toothed wheels.
Condition Confirmed Before OrderQuoted condition is confirmed before payment and dispatch.
Warranty & Returns12 Months standard warranty and 30-day return request period.International DeliveryShipping method is selected according to destination and shipment size.
Technical Source PolicySpecifications are published only when supported by product or manufacturer references.
NEED THIS PART?

IS200TTURH1CFD

Send the quantity and destination country. We will confirm stock, condition, price and lead time.

Get Product Updates and Stock Availability Alerts

    REQUEST A QUOTE

    Check Price & Availability

    ProductGeneral Electric IS200TTURH1CFD Mark VI / Mark VIe Terminal Turbine Board
    Part Number: IS200TTURH1CFD

      Request a Quote

      Send us the required quantity and destination. We will reply with current availability, lead time and final pricing.

      Home
      Products
      Account