HomeGeneral ElectricMark VI / Mark VIeDiscrete Contact Input/Output Terminal BoardGeneral Electric IS220PDIOH1A Mark VI / Mark VIe Discrete Contact Input/Output Terminal Board
General Electric•Discrete Contact Input/Output Terminal Board

General Electric IS220PDIOH1A Mark VI / Mark VIe Discrete Contact Input/Output Terminal Board

Pricing
Request Pricing
Contact us for current price and availability.

The General Electric IS220PDIOH1A is a Discrete Contact Input/Output Terminal Board for Mark VI / Mark VIe control systems. This discrete I/O pack mounts directly onto compatible terminal boards including TDBS and TDBT. It provides an electrical interface between Ethernet networks and discrete field circuits. The pack accepts up to 24 contact inputs and controls 12 relay outputs. Dual RJ45 Ethernet ports maintain concurrent network communications

ManufacturerGeneral Electric
Part NumberIS220PDIOH1A
Product TypeDiscrete Contact Input/Output Terminal Board
ConditionNew
Warranty12 Months
AvailabilityRequest current stock
12-Month Warranty30-Day Return Request WindowGlobal Shipping Support
✓
12 Months WarrantyCommercial warranty confirmed with quotation.
↩
30-Day Return RequestEligible returns subject to authorization.
✈
Worldwide ShippingCourier and freight options for international orders.
#
Part Number VerificationSend a label photo when suffix or revision is uncertain.
PRODUCT INFORMATION

Product Overview

The General Electric IS220PDIOH1A is a Discrete Contact Input/Output Terminal Board for Mark VI / Mark VIe control systems. This discrete I/O pack mounts directly onto compatible terminal boards including TDBS and TDBT. It provides an electrical interface between Ethernet networks and discrete field circuits. The pack accepts up to 24 contact inputs and controls 12 relay outputs. Dual RJ45 Ethernet ports maintain concurrent network communications across distributed control networks.

The assembly contains an Ethernet processor board coupled to a discrete input and output acquisition board. Power input circuitry includes a soft-start circuit to limit current inrush upon power cable connection. Onboard flash memory stores module firmware that verifies hardware identity before initiating signal acquisition. Status light-emitting diodes deliver visual diagnostics for contact input states and relay command circuits. The pack also features an infrared port for local serial diagnostic communications.

TECHNICAL DATA

Technical Specifications

ParameterSpecification
Ac voltage rejection60 V RMS
Input FilterHardware filter, 4 ms
Input Signal LogicActive High / Active Low
Input Voltage Range5V DC / 24V DC
Input isolation in pack1500 V
IsolationOptical or Galvanic Isolation
Mounting TypeDIN Rail
Number of input channels24
Number of relay command channels12
Operating Temperature-40°C to +70°C
Output Voltage Range5V DC – 250V AC
Response Time<5ms
Size15.875 cm high x 10.795 cm wide
TECHNICAL INFORMATION

Features

  • Accepts 24 discrete contact input channels with variable threshold comparator circuits.
  • Controls 12 discrete relay command channels with integrated load current sensing.
  • Provides optical or galvanic isolation rated up to 1500 V in the pack.
  • Features dual auto-negotiating 10/100 MB/s Ethernet ports running active concurrent connections.
  • Includes an input hardware filter with a 4 ms time constant.
  • Supplies onboard status light-emitting diodes for local visual channel diagnostics.
TECHNICAL INFORMATION

Applications

  • General Electric Mark VIe distributed control systems for turbine automation.
  • Simplex discrete input and output configurations utilizing TDBS terminal boards.
  • Triple Modular Redundant discrete control architectures paired with TDBT terminal boards.
TECHNICAL INFORMATION

Connections / Interfaces

  • Two RJ45 Ethernet ports provide dual network communication lines.
  • A DC-62 pin connector connects directly to the mating terminal board.
  • A three-pin power connector supplies local DC input voltage.
  • An infrared serial port facilitates local diagnostic communications.
TECHNICAL INFORMATION

Installation Guidelines

  1. Plug the pack directly into the mating DC-62 connector on the terminal board.
  2. Secure the mechanical attachment using threaded studs adjacent to the Ethernet ports.
  3. Align the mounting bracket so no right-angle force affects the DC-62 connector.
  4. Connect ENET1 to the network path assigned to the R controller.
  5. Insert the power plug while energized because internal soft-start circuits control inrush current.
TECHNICAL INFORMATION

Configuration Guidelines

  1. The module processor acquires its IP address automatically through standard DHCP requests.
  2. Internal application code validates terminal board ID records before activating acquisition functions.
  3. Both Ethernet channels remain actively engaged without requiring primary failover switching.
  4. Input signal logic supports configuration for active high or active low operation.
TECHNICAL INFORMATION

Compatibility

  • Connects to TDBS terminal boards for simplex discrete input and output configurations.
  • Mounts onto TDBT terminal boards in sets of three for Triple Modular Redundant systems.
  • Operates within General Electric Mark VIe distributed control architectures.
COMPATIBILITY

Compatibility & Replacement

COMPATIBLE MODELSConnects to TDBS terminal boards for simplex discrete input and output configurations. Mounts onto TDBT terminal boards in sets of three for Triple Modular Redundant systems. Operates within General Electric Mark VIe distributed control architectures.

Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.

PART VERIFICATION

Before You Order

Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.

01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS

From RFQ to Dispatch

1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ

Frequently Asked Questions

What is the primary function of the IS220PDIOH1A?
The IS220PDIOH1A interfaces 24 contact inputs and 12 relay outputs to Mark VIe Ethernet networks.
Can the IS220PDIOH1A be plugged in while powered?
Yes, the module has internal soft-start circuitry that controls current inrush during power application.
Which terminal boards connect with the IS220PDIOH1A pack?
It mounts directly onto TDBS terminal boards for simplex systems and TDBT boards for TMR applications.
How do the dual Ethernet ports operate on the IS220PDIOH1A?
Both Ethernet ports remain active simultaneously to ensure continuous operation without failover delays.
Condition Confirmed Before OrderQuoted condition is confirmed before payment and dispatch.
Warranty & Returns12 Months standard warranty and 30-day return request period.International DeliveryShipping method is selected according to destination and shipment size.
Technical Source PolicySpecifications are published only when supported by product or manufacturer references.
NEED THIS PART?

IS220PDIOH1A

Send the quantity and destination country. We will confirm stock, condition, price and lead time.

Get Product Updates and Stock Availability Alerts

    REQUEST A QUOTE

    Check Price & Availability

    ProductGeneral Electric IS220PDIOH1A Mark VI / Mark VIe Discrete Contact Input/Output Terminal Board
    Part Number: IS220PDIOH1A

      Request a Quote

      Send us the required quantity and destination. We will reply with current availability, lead time and final pricing.

      Home
      Products
      Account