HomeAllen-BradleyControlLogixAC Input ModuleAllen-Bradley 1756-IA16 ControlLogix AC Input Module
Allen-Bradley•AC Input Module

Allen-Bradley 1756-IA16 ControlLogix AC Input Module

Pricing
Request Pricing
Contact us for current price and availability.

The Allen-Bradley 1756-IA16 ControlLogix AC Input Module provides 16 digital input points. It occupies one ControlLogix chassis slot. The module accepts nominal 120V AC input signals arranged across two isolated groups. Hardware Series A provides software-configurable input filter times, input time stamping, and cyclic updates.

ManufacturerAllen-Bradley
Part Number1756-IA16
Product TypeAC Input Module
ConditionNew
Warranty12 Months
AvailabilityRequest current stock
12-Month Warranty30-Day Return Request WindowGlobal Shipping Support
✓
12 Months WarrantyCommercial warranty confirmed with quotation.
↩
30-Day Return RequestEligible returns subject to authorization.
✈
Worldwide ShippingCourier and freight options for international orders.
#
Part Number VerificationSend a label photo when suffix or revision is uncertain.
PRODUCT INFORMATION

Product Overview

Revision scope: These specifications describe 1756-IA16/A (Series A). Check the corresponding technical data before specifying another hardware series.

The Allen-Bradley 1756-IA16 ControlLogix AC Input Module provides 16 digital input points. It occupies one ControlLogix chassis slot. The module accepts nominal 120V AC input signals arranged across two isolated groups. Hardware Series A provides software-configurable input filter times, input time stamping, and cyclic updates.

This module features basic continuous isolation of 125V between input groups and backplane circuits. Backplane current draw is 100 mA at 5.1V DC and 2 mA at 24V DC. Total backplane power consumption is 0.58 W. Maximum power dissipation reaches 5.8 W at 60 °C. Front status indicators provide immediate visual confirmation of field input operation.

TECHNICAL DATA

Technical Specifications

These specifications describe 1756-IA16/A (Series A). Check the corresponding technical data before specifying another hardware series.

ParameterSpecification
Number of Inputs16 points (8 points per group)
Nominal Input Voltage120V AC (50/60 Hz)
Operating Voltage Range74–132V AC, 47–63 Hz
Backplane Current @ 5.1V DC100 mA
Backplane Current @ 24V DC2 mA
Total Backplane Power0.58 W
Maximum Power Dissipation5.8 W @ 60 °C (140 °F)
Thermal Dissipation18.41 BTU/hr
Off-State Voltage (Max)20V AC
Off-State Current (Max)2.5 mA
On-State Current5 mA min @ 74V AC, 13 mA max @ 132V AC
Input Impedance10.15 kΩ max @ 132V AC, 60 Hz
Continuous Isolation Voltage125V (continuous), basic insulation
Operating Temperature0 to 60 °C (32 to 140 °F)
Operating Humidity5% to 95% non-condensing
Slot Width1 slot
TECHNICAL INFORMATION

Order Information

Revision Part #Also known asReference Price
1756-IA16 Ser A1756-IA16/A, Series AUSD 129.00–279.00, indicative

Reference prices are observed third-party market prices for the stated revision, not a final Aituos quotation.

TECHNICAL INFORMATION

Features

  • Provides 16 digital input points organized into two isolated groups of 8 points.
  • Operates over an input range of 74 to 132V AC at 47 to 63 Hz.
  • Features user-selectable hardware filter times for off-to-on and on-to-off transitions.
  • Supports change-of-state detection and input time stamping to within ±200 µs.
  • Delivers 125V continuous basic isolation between signal inputs and backplane circuitry.
  • Installs into a single standard slot within any ControlLogix I/O chassis.
TECHNICAL INFORMATION

Applications

  • Discrete 120V AC limit switch and proximity sensor monitoring.
  • Motor starter auxiliary contact and control circuit feedback sensing.
  • Pushbutton and selector switch monitoring in industrial control panels.
  • General factory automation discrete AC signal aggregation.
TECHNICAL INFORMATION

Connections / Interfaces

  • Compatible with 20-pin Removable Terminal Block housings 1756-TBNH and 1756-TBSH.
  • Connects directly to the ControlLogix 1756 chassis backplane bus.
  • Supports user-defined mechanical keying on the removable terminal block.
TECHNICAL INFORMATION

Installation Guidelines

  1. Insert the module into any available slot in a ControlLogix chassis until firmly seated.
  2. Wire field signals to the 20-pin removable terminal block before installing onto the module.
  3. Follow Category 1 conductor routing guidelines to prevent electrical noise interference.
  4. Maintain ambient operating temperatures between 0 °C and 60 °C.
TECHNICAL INFORMATION

Configuration Guidelines

  1. Select off-to-on input filter delay times of 1 ms or 2 ms.
  2. Set on-to-off filter delays to 9 ms or 18 ms for debounce control.
  3. Configure electronic keying parameters within the controller programming software.
TECHNICAL INFORMATION

Compatibility

  • Installs directly into all Allen-Bradley ControlLogix 1756 I/O chassis slots.
  • Requires 1756-TBNH or 1756-TBSH removable terminal blocks for field connections.
TECHNICAL INFORMATION

Compliance and Certifications

  • cULus Listed Industrial Control Equipment certified under UL File E65584
  • UL Listed for Class I, Division 2 Groups A, B, C, D Hazardous Locations
  • CE Marked compliant with EN 61326-1, EN 61000-6-2, EN 61000-6-4, and EN 61131-2
  • FM Approved for Class I, Division 2 Groups A, B, C, D Hazardous Locations
  • Compliant with UKCA, RCM, KC, and Morocco regulatory standards
TECHNICAL RESOURCES

Documentation

COMPATIBILITY

Compatibility & Replacement

COMPATIBLE MODELSInstalls directly into all Allen-Bradley ControlLogix 1756 I/O chassis slots. Requires 1756-TBNH or 1756-TBSH removable terminal blocks for field connections.

Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.

PART VERIFICATION

Before You Order

Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.

01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS

From RFQ to Dispatch

1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ

Frequently Asked Questions

What is the operating voltage range for the 1756-IA16/A module?
The operating voltage range is 74 to 132V AC at 47 to 63 Hz. Nominal voltage is 120V AC.
Which terminal blocks work with the Allen-Bradley 1756-IA16 Series A?
Field wiring connects using 20-pin removable terminal block housings. Compatible models include 1756-TBNH screw clamp and 1756-TBSH spring clamp blocks.
What is the market reference price for the 1756-IA16/A module?
Observed market reference pricing spans approximately $129.00 to $279.00 USD across conditions. These figures are indicative market reference pricing only and are not a final quotation.
Condition Confirmed Before OrderQuoted condition is confirmed before payment and dispatch.
Warranty & Returns12 Months standard warranty and 30-day return request period.International DeliveryShipping method is selected according to destination and shipment size.
Technical Source PolicySpecifications are published only when supported by product or manufacturer references.
NEED THIS PART?

1756-IA16

Send the quantity and destination country. We will confirm stock, condition, price and lead time.

Get Product Updates and Stock Availability Alerts

    REQUEST A QUOTE

    Check Price & Availability

    ProductAllen-Bradley 1756-IA16 ControlLogix AC Input Module
    Part Number: 1756-IA16

      Request a Quote

      Send us the required quantity and destination. We will reply with current availability, lead time and final pricing.

      Home
      Products
      Account