PRODUCT INFORMATION
Product Overview
The Bently Nevada 3500/60 is a six-channel Temperature Monitor for the 3500 system. It conditions RTD and thermocouple temperature inputs for machinery measurement. The monitor compares incoming signals with programmable alarm setpoints. It alerts operators when temperature inputs exceed defined thresholds.
Users can configure the unit for non-isolated RTD, thermocouple, or mixed inputs. The isolated thermocouple option provides 250 Vdc channel-to-channel isolation. In Triple Modular Redundant configurations, monitors install in groups of three adjacent units. This base monitor hardware does not include recorder output channels.
TECHNICAL DATA
Technical Specifications
| Parameter | Specification |
|---|
| Channel Count | 6 |
|---|
| Supported Input Families | RTD and thermocouple temperature inputs |
|---|
| Input Conditioning | Conditions temperature inputs for measurement |
|---|
| Alarm Comparison | Compares inputs with programmable alarm setpoints |
|---|
| Non-isolated I/O Configuration | RTD, thermocouple, or mixed inputs |
|---|
| Isolated Thermocouple I/O | 250 Vdc channel-to-channel isolation |
|---|
| Recorder Outputs | No recorder output channels |
|---|
| TMR Installation | Groups of 3 adjacent monitors |
|---|
TECHNICAL INFORMATION
Features
- Accepts six RTD, thermocouple, or mixed temperature inputs.
- Provides 250 Vdc channel-to-channel isolation for isolated thermocouple inputs.
- Compares measured temperature inputs against programmable alarm setpoints.
- Supports Triple Modular Redundant architecture using three adjacent monitors.
- Includes no recorder output channels in the base monitor configuration.
TECHNICAL INFORMATION
Applications
- Continuous machinery temperature monitoring across industrial facilities.
- Triple Modular Redundant protection schemes requiring three adjacent monitors.
TECHNICAL INFORMATION
Connections / Interfaces
- Accommodates six RTD or thermocouple sensor input channels.
- Supports non-isolated configurations for RTD, thermocouple, or mixed inputs.
- Provides 250 Vdc channel-to-channel isolation on isolated thermocouple I/O.
TECHNICAL INFORMATION
Installation Guidelines
- Install monitors in groups of three adjacent rack positions for TMR applications.
- Connect field wiring according to the selected isolated or non-isolated I/O module.
TECHNICAL INFORMATION
Configuration Guidelines
- Configure channels for RTD, thermocouple, or mixed temperature inputs.
- Set programmable alarm setpoints for temperature input channels.
- Select isolated thermocouple I/O when 250 Vdc channel-to-channel isolation is needed.
TECHNICAL INFORMATION
Compatibility
- Bently Nevada 3500 monitoring system racks.
- Non-isolated RTD and thermocouple I/O modules.
- Isolated thermocouple I/O modules.
COMPATIBILITY
Compatibility & Replacement
COMPATIBLE MODELSBently Nevada 3500 monitoring system racks. Non-isolated RTD and thermocouple I/O modules. Isolated thermocouple I/O modules.
Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.
PART VERIFICATION
Before You Order
Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.
01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS
From RFQ to Dispatch
1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ
Frequently Asked Questions
How many input channels does the Bently Nevada 3500/60 provide?
The Bently Nevada 3500/60 provides six channels for RTD and thermocouple temperature inputs.
Does the 3500/60 monitor provide channel isolation?
Yes. The isolated thermocouple configuration provides 250 Vdc channel-to-channel isolation.
Does the 3500/60 include recorder outputs?
No. The 3500/60 base temperature monitor includes no recorder output channels.
How is the 3500/60 deployed in TMR systems?
In Triple Modular Redundant systems, 3500/60 monitors are installed in groups of three adjacent units.