HomeGeneral ElectricPACSystems RX3iAnalog Input ModuleGeneral Electric IC695ALG616-CA PACSystems RX3i Analog Input Module
General Electric•Analog Input Module

General Electric IC695ALG616-CA PACSystems RX3i Analog Input Module

Reference Price Range
$819.00
Indicative market reference range only. This is not a final quotation. Final price depends on product condition, current stock, quantity, destination and delivery requirements.

The General Electric IC695ALG616-CA is an Analog Input Module for the PACSystems RX3i series. It provides 16 single-ended channels or 8 differential channels. The hardware incorporates a 24-bit analog-to-digital converter. It accepts standard current and voltage signals. Available ranges include plus-minus 10 V, 0 to 10 V, 4 to 20 mA, and plus-minus 20 mA.

ManufacturerGeneral Electric
Part NumberIC695ALG616-CA
Product TypeAnalog Input Module
ConditionNew
Warranty12 Months
Lifecycle StatusRevision CA operates with firmware version 1.01. Hardware versions up to EA cannot be upgraded in the field to firmware 2.00 or later.
AvailabilityRequest current stock
12-Month Warranty30-Day Return Request WindowGlobal Shipping Support
✓
12 Months WarrantyCommercial warranty confirmed with quotation.
↩
30-Day Return RequestEligible returns subject to authorization.
✈
Worldwide ShippingCourier and freight options for international orders.
#
Part Number VerificationSend a label photo when suffix or revision is uncertain.
PRODUCT INFORMATION

Product Overview

The General Electric IC695ALG616-CA is an Analog Input Module for the PACSystems RX3i series. It provides 16 single-ended channels or 8 differential channels. The hardware incorporates a 24-bit analog-to-digital converter. It accepts standard current and voltage signals. Available ranges include plus-minus 10 V, 0 to 10 V, 4 to 20 mA, and plus-minus 20 mA.

Revision CA features updated hardware and operates on firmware revision 1.01. The module draws 350 mA at 5 VDC and 200 mA at 3.3 VDC from the backplane. Total module power dissipation is 4.25 W. Terminal-to-backplane optical isolation is rated at 250 VAC continuous and 1500 VAC for one minute. Input channels are non-isolated channel-to-channel.

TECHNICAL DATA

Technical Specifications

ParameterSpecification
Input count16 single-ended or 8 differential
Channel isolationNonisolated channel-to-channel
Current ranges0–20 mA, 4–20 mA, ±20 mA
Voltage ranges±10 V, 0–10 V, ±5 V, 0–5 V, 1–5 V
ADC resolution24 bit
Output data format32-bit IEEE floating point or 16-bit integer in a 32-bit field
Selectable filters8, 12, 16, 40, 200, 500 Hz
5 V backplane current350 mA
3.3 V backplane current200 mA
Power dissipation4.25 W
Voltage input impedanceGreater than 100 kohm
Current input resistance249 ohm ±1%
Open-circuit detection1 s maximum
Continuous overvoltage±60 VDC
Continuous overcurrent±28 mA
Terminal-to-backplane isolation250 VAC continuous; 1500 VAC for 1 minute
Revision CA firmware1.01
Revision CA changeUpdated hardware
TECHNICAL INFORMATION

Features

  • Provides 16 single-ended or 8 differential analog input channels.
  • Uses a 24-bit analog-to-digital converter for signal resolution.
  • Selectable hardware filter frequencies include 8, 12, 16, 40, 200, and 500 Hz.
  • Supports 32-bit floating point and 16-bit integer data formats.
  • Features terminal-to-backplane isolation rated at 250 VAC continuous.
  • Includes internal 249 ohm current input resistors with 1 percent tolerance.
  • Provides open-circuit detection with a maximum response time of 1 second.
TECHNICAL INFORMATION

Applications

  • Analog signal acquisition in PACSystems RX3i controller racks.
  • Current loop processing for 4 to 20 mA transmitters.
  • Voltage monitoring for industrial instruments operating up to plus-minus 10 V.
TECHNICAL INFORMATION

Connections / Interfaces

  • For differential inputs, two adjacent terminals form one channel.
  • Connect differential voltage across adjacent Channel IN terminals.
  • Connect differential current between Channel IN+ and Current Return terminals.
  • Place a jumper between Channel IN- and Current Return for current inputs.
  • Keep the differential current jumper resistance at or below 25 milliohms.
  • Tie cable shields to the backplane ground bar using M3 tapped holes.
  • Tie common terminals to signal ground to reduce channel-to-channel crosstalk.
TECHNICAL INFORMATION

Installation Guidelines

  1. Insert the module into an available PACSystems RX3i backplane slot.
  2. Insert the door card matching either single-ended or differential wiring layout.
  3. Do not connect field shields to module terminals because shield terminals are omitted.
TECHNICAL INFORMATION

Configuration Guidelines

  1. Requires RX3i CPU firmware version 3.00 or later.
  2. Requires programming software version 5.0 SP3 or later.
  3. Configure Channel Value Format as 32-Bit Floating Point when using software filtering on revision 1.01.
TECHNICAL INFORMATION

Compatibility

  • Compatible with General Electric PACSystems RX3i universal backplanes.
  • Requires PACSystems RX3i CPU version 3.00 or higher.
  • Requires programming software version 5.0 SP3 or higher.
TECHNICAL INFORMATION

Lifecycle / Replacement Information

  • Revision CA operates with firmware version 1.01.
  • Hardware versions up to EA cannot be upgraded in the field to firmware 2.00 or later.
TECHNICAL RESOURCES

Documentation

COMPATIBILITY

Compatibility & Replacement

COMPATIBLE MODELSCompatible with General Electric PACSystems RX3i universal backplanes. Requires PACSystems RX3i CPU version 3.00 or higher. Requires programming software version 5.0 SP3 or higher.

Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.

PART VERIFICATION

Before You Order

Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.

01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS

From RFQ to Dispatch

1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ

Frequently Asked Questions

What is the channel capacity of the IC695ALG616-CA?
The module supports 16 single-ended channels or 8 differential channels.
What software and CPU versions are required for the IC695ALG616-CA?
The module requires programming software version 5.0 SP3 or newer and RX3i CPU firmware 3.00 or newer.
Can the IC695ALG616-CA be field upgraded to firmware 2.00?
No. Hardware versions up to revision EA cannot be field-upgraded to firmware 2.00 or higher.
What is the reference price for the IC695ALG616-CA?
Observed pricing is approximately $819.00 USD for refurbished units. This is an indicative market reference only and is not a final quotation.
Condition Confirmed Before OrderQuoted condition is confirmed before payment and dispatch.
Warranty & Returns12 Months standard warranty and 30-day return request period.International DeliveryShipping method is selected according to destination and shipment size.
Technical Source PolicySpecifications are published only when supported by product or manufacturer references.
NEED THIS PART?

IC695ALG616-CA

Send the quantity and destination country. We will confirm stock, condition, price and lead time.

Get Product Updates and Stock Availability Alerts

    REQUEST A QUOTE

    Check Price & Availability

    ProductGeneral Electric IC695ALG616-CA PACSystems RX3i Analog Input Module
    Part Number: IC695ALG616-CA

      Request a Quote

      Send us the required quantity and destination. We will reply with current availability, lead time and final pricing.

      Home
      Products
      Account