HomeHoneywellHC900Digital Output ModuleHoneywell 900H32-0302 HC900 Digital Output Module
Honeywell•Digital Output Module

Honeywell 900H32-0302 HC900 Digital Output Module

Pricing
Request Pricing
Contact us for current price and availability.

The Honeywell 900H32-0302 is a 32-channel digital output module designed for HC900 process automation systems. This module provides 32 current-sourcing high-side outputs across an operating range of 10.5 to 32 VDC. The outputs are split into two galvanically isolated groups of 16 channels to prevent ground loop interaction. Each channel supports up to 0.5 A continuous resistive load under rated operating temperatures.

ManufacturerHoneywell
Part Number900H32-0302
Product TypeDigital Output Module
ConditionNew
Warranty12 Months
AvailabilityRequest current stock
12-Month Warranty30-Day Return Request WindowGlobal Shipping Support
✓
12 Months WarrantyCommercial warranty confirmed with quotation.
↩
30-Day Return RequestEligible returns subject to authorization.
✈
Worldwide ShippingCourier and freight options for international orders.
#
Part Number VerificationSend a label photo when suffix or revision is uncertain.
PRODUCT INFORMATION

Product Overview

The Honeywell 900H32-0302 is a 32-channel digital output module designed for HC900 process automation systems. This module provides 32 current-sourcing high-side outputs across an operating range of 10.5 to 32 VDC. The outputs are split into two galvanically isolated groups of 16 channels to prevent ground loop interaction. Each channel supports up to 0.5 A continuous resistive load under rated operating temperatures.

Integrated protection includes active current limiting configured across four independent groups of eight outputs. Fault clearing occurs automatically without requiring an external power cycle or fuse replacement. Backplane power demands remain low, consuming 235 mA at 5 VDC and zero current at 24 VDC. External field connections require a dedicated 36-terminal Euro-style block mounted directly to the module front.

TECHNICAL DATA

Technical Specifications

ParameterSpecification
Outputs32 current-sourcing, high-side outputs
Galvanic groupsTwo isolated groups of 16
Operating voltage10.5–32 VDC
Peak voltage32 VDC
On-state voltage drop0.15 VDC at 0.5 A load
Maximum load0.5 A per point, 6 A per group, 12 A per module for resistive load
Lamp load0.25 A per point; 5 mH maximum
Overload protectionActive limiting in four groups of 8; power cycling is not required
Leakage current0.15 mA at 32 VDC
Inrush current2 A for 10 ms
Response time6 ms off-to-on and 6 ms on-to-off, excluding scan/backplane time
Backplane load5 V at 235 mA; 24 V at 0 mA
Dimensions137 mm high × 35.6 mm wide
Weight180 g
Terminal requirementEuro-style 36-terminal block
Channel restrictionOutputs 17–32 cannot be used for TPO, PPO, or TPSC
TECHNICAL INFORMATION

Features

  • 32 current-sourcing high-side discrete outputs rated for 10.5 to 32 VDC operation.
  • Two galvanically isolated channel groups of 16 outputs each.
  • Active current overload limiting arranged in four groups of eight points.
  • Automatic recovery from overload conditions without requiring field power interruption.
  • Low backplane power draw of 235 mA at 5 VDC.
  • High-density design utilizing a standard 36-terminal Euro-style connector block.
TECHNICAL INFORMATION

Applications

  • HC900 process automation systems requiring high-density discrete output control.
  • Switching 24 VDC field actuators, pilot lamps, intermediate relays, and solenoids.
  • Distributed I/O rack installations requiring group-isolated DC sourcing circuits.
TECHNICAL INFORMATION

Connections / Interfaces

  • Requires a removable Euro-style 36-terminal block for field wiring connection.
  • Provides two isolated wiring groups with independent field power supply feeds.
  • High-side sourcing topology delivers external DC power directly to grounded field loads.
TECHNICAL INFORMATION

Installation Guidelines

  1. Insert module into any available I/O slot in an HC900 rack enclosure.
  2. Ensure external field power is de-energized before seating or removing the terminal block.
  3. Maintain total module load at or below 12 A across all active output circuits.
TECHNICAL INFORMATION

Configuration Guidelines

  1. Channels 17 through 32 cannot be assigned to TPO, PPO, or TPSC pulse control blocks.
  2. Configure output state hold or de-energize behavior using HC900 system software during scanner communication loss.
  3. Calculate aggregate group load to ensure current remains below 6 A per 16-channel bank.
TECHNICAL INFORMATION

Compatibility

  • Compatible with Honeywell ControlEdge HC900 controller racks and remote I/O scanners.
  • Requires a 36-terminal Euro-style terminal block for wiring installation.
TECHNICAL RESOURCES

Documentation

COMPATIBILITY

Compatibility & Replacement

COMPATIBLE MODELSCompatible with Honeywell ControlEdge HC900 controller racks and remote I/O scanners. Requires a 36-terminal Euro-style terminal block for wiring installation.

Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.

PART VERIFICATION

Before You Order

Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.

01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS

From RFQ to Dispatch

1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ

Frequently Asked Questions

What is the maximum output current rating for the Honeywell 900H32-0302?
Each channel handles up to 0.5 A resistive load, with 6 A per group and 12 A total.
Can all channels on the 900H32-0302 module be used for pulse output functions?
No, outputs 17 through 32 cannot be used for TPO, PPO, or TPSC pulse configurations.
How does the 900H32-0302 handle overcurrent faults?
It uses active current limiting in four groups of eight channels. Power cycling is not required.
What type of terminal block is required for wiring this module?
The module requires a Euro-style 36-terminal removable block for all field I/O connections.
Condition Confirmed Before OrderQuoted condition is confirmed before payment and dispatch.
Warranty & Returns12 Months standard warranty and 30-day return request period.International DeliveryShipping method is selected according to destination and shipment size.
Technical Source PolicySpecifications are published only when supported by product or manufacturer references.
NEED THIS PART?

900H32-0302

Send the quantity and destination country. We will confirm stock, condition, price and lead time.

Get Product Updates and Stock Availability Alerts

    REQUEST A QUOTE

    Check Price & Availability

    ProductHoneywell 900H32-0302 HC900 Digital Output Module
    Part Number: 900H32-0302

      Request a Quote

      Send us the required quantity and destination. We will reply with current availability, lead time and final pricing.

      Home
      Products
      Account