HomeAllen-BradleySLC 500ControllerAllen-Bradley 1747-L511 SLC 500 Controller
Allen-Bradley•Controller

Allen-Bradley 1747-L511 SLC 500 Controller

Pricing
Request Pricing
Contact us for current price and availability.

The Allen-Bradley 1747-L511 SLC 500 Controller is an SLC 5/01 processor module. The unit provides 1K instructions of user program memory. It mounts directly into slot 0 of a 1746 modular chassis. The controller supports up to 30 local I/O module slots across three interconnected chassis. Total local capacity reaches a maximum of 960 digital points or 480 analog points.

ManufacturerAllen-Bradley
Part Number1747-L511
Product TypeController
ConditionNew
Warranty12 Months
Lifecycle StatusThe hardware design corresponds to the SLC 5/01 Series A release. Verify existing chassis slot allocation and hardware series prior to replacement.
AvailabilityRequest current stock
12-Month Warranty30-Day Return Request WindowGlobal Shipping Support
✓
12 Months WarrantyCommercial warranty confirmed with quotation.
↩
30-Day Return RequestEligible returns subject to authorization.
✈
Worldwide ShippingCourier and freight options for international orders.
#
Part Number VerificationSend a label photo when suffix or revision is uncertain.
PRODUCT INFORMATION

Product Overview

Revision scope: These specifications describe 1747-L511/A (Series A). Check the corresponding technical data before specifying another hardware series.

The Allen-Bradley 1747-L511 SLC 500 Controller is an SLC 5/01 processor module. The unit provides 1K instructions of user program memory. It mounts directly into slot 0 of a 1746 modular chassis. The controller supports up to 30 local I/O module slots across three interconnected chassis. Total local capacity reaches a maximum of 960 digital points or 480 analog points.

Internal logic is retained by capacitor-backed RAM during brief power interruptions. Optional EEPROM memory modules provide non-volatile program retention. Compatible backup memory modules include the 1747-M1 and 1747-M2. Front indicators display Run, CPU Fault, Forced I/O, and Battery Low status. The backplane current draw requires 350 mA at 5V DC and 105 mA at 24V DC.

TECHNICAL DATA

Technical Specifications

These specifications describe 1747-L511/A (Series A). Check the corresponding technical data before specifying another hardware series.

ParameterSpecification
SpecificationValue
Processor TypeSLC 5/01, Series A
User Memory1K instructions (maximum)
Maximum Local Digital I/O960 points (absolute maximum)
Maximum Local Analog I/O480 points
Program Scan Time8 ms/K (typical)
I/O Scan Time2.6 ms (typical)
Communication PortDH-485 (peer-to-peer; responds to messages only, cannot initiate)
Remote I/O SupportNot supported
Maximum Local I/O Chassis3
Maximum I/O Module Slots (Local)30
Memory BackupCapacitor-backed RAM; optional EEPROM (1747-M1 or 1747-M2)
Backplane Current Draw (5V DC)350 mA
Backplane Current Draw (24V DC)105 mA
Ambient Operating Temperature0 to +60°C (+32 to +140°F)
MountingSlot 0 of 1746 modular chassis
Status IndicatorsRun, CPU Fault, Forced I/O, Battery Low LEDs
CertificationsUL Listed (US and Canadian Safety Standards), CE, C-Tick
TECHNICAL INFORMATION

Order Information

Revision Part #Also known asReference Price
1747-L511 Ser A1747-L511/A, Series AUSD 239.00, indicative (Used/Refurbished)
1747-L511 Ser B1747-L511/B, Series BUSD 128.00–389.00, indicative

Reference prices are observed third-party market prices for the stated revision, not a final Aituos quotation.

TECHNICAL INFORMATION

Features

  • Provides 1K instructions of user memory for program execution.
  • Mounts directly into slot 0 of any modular 1746 chassis.
  • Delivers a typical program scan time of 8 ms per 1K.
  • Includes diagnostic LEDs for Run, CPU Fault, Forced I/O, and Battery Low.
  • Uses capacitor-backed RAM and supports optional 1747-M1 or 1747-M2 EEPROM modules.
  • Supports up to 30 local module slots across three chassis.
TECHNICAL INFORMATION

Connections / Interfaces

  • The module includes one DH-485 communication port.
  • The DH-485 port responds to network messages but cannot initiate communications.
  • Remote I/O connections are not supported on this unit.
TECHNICAL INFORMATION

Installation Guidelines

  1. Mount the controller exclusively into slot 0 of the 1746 chassis.
  2. Maintain an ambient operating temperature between 0 and 60 degrees Celsius.
  3. Ensure power supply capacity covers 350 mA at 5V DC and 105 mA at 24V DC.
TECHNICAL INFORMATION

Configuration Guidelines

  1. Configure hardware across up to three local chassis.
  2. Local expansion accommodates up to 30 modular I/O slots.
  3. Install an optional 1747-M1 or 1747-M2 EEPROM module for non-volatile backup.
TECHNICAL INFORMATION

Compatibility

  • Compatible with Allen-Bradley 1746 modular chassis.
  • Compatible with 1746 local digital and analog I/O modules.
  • Supports optional 1747-M1 and 1747-M2 memory backup modules.
TECHNICAL INFORMATION

Lifecycle / Replacement Information

  • The hardware design corresponds to the SLC 5/01 Series A release.
  • Verify existing chassis slot allocation and hardware series prior to replacement.
TECHNICAL INFORMATION

Compliance and Certifications

  • UL Listed for United States and Canadian safety standards.
  • CE compliant for applicable European standards.
  • C-Tick certified for Australian standards.
COMPATIBILITY

Compatibility & Replacement

COMPATIBLE MODELSCompatible with Allen-Bradley 1746 modular chassis. Compatible with 1746 local digital and analog I/O modules. Supports optional 1747-M1 and 1747-M2 memory backup modules.

Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.

PART VERIFICATION

Before You Order

Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.

01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS

From RFQ to Dispatch

1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ

Frequently Asked Questions

What is the user memory capacity of the Allen-Bradley 1747-L511?
The 1747-L511 provides up to 1K instructions of user memory. Capacitor-backed RAM preserves user programs during power loss.
Can the 1747-L511 initiate messages over DH-485?
No. The DH-485 communication port operates as a responder node only and cannot initiate messages.
Where must the 1747-L511 be installed in a chassis?
The 1747-L511 controller must always be installed into slot 0 of a 1746 chassis.
What is the reference price for the 1747-L511?
Market reference pricing is approximately USD 239.00 for used or refurbished units. These figures are indicative market reference pricing only and are not a final quotation.
Condition Confirmed Before OrderQuoted condition is confirmed before payment and dispatch.
Warranty & Returns12 Months standard warranty and 30-day return request period.International DeliveryShipping method is selected according to destination and shipment size.
Technical Source PolicySpecifications are published only when supported by product or manufacturer references.
NEED THIS PART?

1747-L511

Send the quantity and destination country. We will confirm stock, condition, price and lead time.

Get Product Updates and Stock Availability Alerts

    REQUEST A QUOTE

    Check Price & Availability

    ProductAllen-Bradley 1747-L511 SLC 500 Controller
    Part Number: 1747-L511

      Request a Quote

      Send us the required quantity and destination. We will reply with current availability, lead time and final pricing.

      Home
      Products
      Account