PRODUCT INFORMATION
Product Overview
General Electric 269PLUS-W-100P-HI is a Multilin Motor Management Relay engineered for medium sized electric motors. This device provides protective features designed to extend operating life and reduce unplanned system downtime. Integrated monitoring functions include overload protection, ground fault detection, unbalance correction, and fault diagnosis. The unit also performs internal self-assessment routines during regular operation.
The front faceplate features an integrated keypad, status LEDs, and a forty-eight character alphanumeric display. Operators can configure custom default monitoring screens and inspect real-time alarms, actual values, and programmed setpoints directly. The protective enclosure meets IP40X standards and incorporates flame-retardant materials. Protective algorithms include undercurrent detection and an exponential cooldown model to support frequent motor load cycling.
TECHNICAL DATA
Technical Specifications
| Parameter | Specification |
|---|
| Manufacturer Location | Markham, Ontario, Canada |
|---|
| Software | EnerVista 269 |
|---|
| User Manual | 1601-0013-E4 |
|---|
| Overvoltage Category | II |
|---|
| Pollution Degree | II |
|---|
| Ambient Humidity | 95% non-condensing |
|---|
TECHNICAL INFORMATION
Features
- Integrated 48-character 2-line alphanumeric liquid crystal display with configurable screens
- Front faceplate with status LED indicators, integrated programming keypad, and help key
- Comprehensive protection functions including overload, ground fault, unbalance, and undercurrent detection
- Exponential cooldown calculation to safely permit more frequent motor load cycling
- Internal self-assessment routines and diagnostic logging for streamlined troubleshooting
- Flame-retardant front construction rated to IP40X ingress protection standards
- Configuration and diagnostic interface support through EnerVista 269 software
TECHNICAL INFORMATION
Applications
- Medium sized industrial electric motor protection and continuous management
- Centrifugal pump systems requiring fast detection of suction loss through undercurrent monitoring
- Industrial fan applications requiring immediate notification of airflow loss
- Conveyor systems to detect mechanical decoupling or broken drive belts
TECHNICAL INFORMATION
Connections / Interfaces
- Integrated front keypad with dedicated help key for direct parameter modification
- Two-line alphanumeric liquid crystal display for local diagnostic and status viewing
- Software configuration access supported through EnerVista 269
TECHNICAL INFORMATION
Installation Guidelines
- Install within environments that conform to Pollution Degree II requirements
- Verify electrical supply and system wiring align with Overvoltage Category II specifications
- Maintain ambient relative humidity below 95 percent non-condensing during operation
- Consult General Electric user manual 1601-0013-E4 for panel cutout and wiring instructions
TECHNICAL INFORMATION
Configuration Guidelines
- Configure protection parameters, trip setpoints, and display options using EnerVista 269 software
- Select passive display parameters for default viewing on the two-line display during idle states
- Set undercurrent thresholds according to process equipment mechanical failure characteristics
TECHNICAL INFORMATION
Compatibility
- Compatible with medium sized three-phase electric motors requiring comprehensive protection
- Configurable and managed using General Electric EnerVista 269 setup software
TECHNICAL INFORMATION
Compliance and Certifications
- Front faceplate rated to IP40X ingress protection standards
- Rated for Overvoltage Category II installations
- Rated for Pollution Degree II operational environments
COMPATIBILITY
Compatibility & Replacement
COMPATIBLE MODELSCompatible with medium sized three-phase electric motors requiring comprehensive protection Configurable and managed using General Electric EnerVista 269 setup software
Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.
PART VERIFICATION
Before You Order
Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.
01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS
From RFQ to Dispatch
1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ
Frequently Asked Questions
What is the primary function of the 269PLUS-W-100P-HI relay?
It provides comprehensive protection, fault diagnosis, and monitoring for medium sized industrial electric motors.
What software is used to configure the 269PLUS-W-100P-HI?
General Electric EnerVista 269 software is used to manage settings, setpoints, and diagnostics.
How does the undercurrent protection feature help mechanical equipment?
It detects current drops caused by broken conveyor belts, pump suction loss, or fan airflow loss.
What is the ingress protection rating of the front faceplate?
The front faceplate meets IP40X standards and is constructed from flame-retardant materials.