The General Electric 269PLUS-DO-271-100P-120 Multilin Motor Management Relay provides comprehensive protection for industrial AC motors. This unit also protects driven mechanical equipment coupled to the AC motor. The device belongs to the GE Multilin 269 PLUS equipment family. It features a drawout enclosure configuration.

ManufacturerGeneral Electric
Part Number269PLUS-DO-271-100P-120
Product TypeMotor Management Relay
ConditionNew
Warranty12 Months
Lifecycle StatusDrawout design permits module withdrawal and servicing without shutting down running motors.
AvailabilityRequest current stock
12-Month Warranty30-Day Return Request WindowGlobal Shipping Support
✓
12 Months WarrantyCommercial warranty confirmed with quotation.
↩
30-Day Return RequestEligible returns subject to authorization.
✈
Worldwide ShippingCourier and freight options for international orders.
#
Part Number VerificationSend a label photo when suffix or revision is uncertain.
PRODUCT INFORMATION

Product Overview

The General Electric 269PLUS-DO-271-100P-120 Multilin Motor Management Relay provides comprehensive protection for industrial AC motors. This unit also protects driven mechanical equipment coupled to the AC motor. The device belongs to the GE Multilin 269 PLUS equipment family. It features a drawout enclosure configuration.

Drawout construction enables unit removal from service without causing an operating motor shutdown. This arrangement simplifies routine calibration, hardware testing, and field replacement. The internal circuitry supports 5 A phase and 5 A ground current transformer inputs. Sensor inputs interface with 100 Ohm platinum RTDs. Control power accepts 120 VAC or 125 VDC auxiliary supplies.

TECHNICAL DATA

Technical Specifications

ParameterSpecification
Manufacturer LocationOntario, Canada
SoftwareEnerVista 269
User Manual1601-0013-E4
RFI50 MHz/15W Transmitter
Insulation ResistanceIEC255-5,500 V DC
Dielectric Strength2.0 kV for 1 minute to relays, CTs, power supply
TECHNICAL INFORMATION

Features

  • Drawout case allows module withdrawal without interrupting operating AC motors.
  • Configured for 5 A phase CT and 5 A ground CT sensor inputs.
  • Fail-safe design applied to trip, alarm, Aux 1, and Aux 2 circuits.
  • Normally open contact arrangement provided for alarm, Aux 1, and Aux 2 circuits.
  • Calibrated specifically for 100 Ohm platinum RTD temperature sensors.
  • Operates on 120 VAC or 125 VDC control power.
TECHNICAL INFORMATION

Applications

  • Protection of three-phase AC induction motors in industrial facilities.
  • Protection of driven mechanical equipment coupled to AC motors.
  • Motor protection systems requiring drawout maintenance capability.
TECHNICAL INFORMATION

Connections / Interfaces

  • Terminal blocks accept 5 A phase and 5 A ground CT wiring.
  • Input terminals connect to 100 Ohm platinum RTD sensor elements.
  • Power terminals accommodate 120 VAC or 125 VDC auxiliary supply lines.
TECHNICAL INFORMATION

Installation Guidelines

  1. Securely mount the drawout case inside a control cabinet or switchgear lineup.
  2. Connect 5 A phase and 5 A ground current transformer wiring correctly.
  3. Verify auxiliary control power matches 120 VAC or 125 VDC specifications.
TECHNICAL INFORMATION

Configuration Guidelines

  1. Configure protection parameters using EnerVista 269 software.
  2. Refer to GE instruction manual 1601-0013-E4 for complete setting procedures.
  3. Verify RTD parameters match physical 100 Ohm platinum RTD sensor elements.
TECHNICAL INFORMATION

Compatibility

  • Operates with AC motors and connected mechanical equipment.
  • Interfaces with 100 Ohm platinum RTD sensors.
  • Connects to 5 A phase and 5 A ground current transformers.
TECHNICAL INFORMATION

Lifecycle / Replacement Information

  • Drawout design permits module withdrawal and servicing without shutting down running motors.
TECHNICAL INFORMATION

Compliance and Certifications

  • Drawout versions in the 269 PLUS series do not meet CE compliance.
  • Dielectric strength rated at 2.0 kV for 1 minute across relays, CTs, and power supply.
  • Insulation resistance complies with IEC 255-5 at 500 V DC.
COMPATIBILITY

Compatibility & Replacement

COMPATIBLE MODELSOperates with AC motors and connected mechanical equipment. Interfaces with 100 Ohm platinum RTD sensors. Connects to 5 A phase and 5 A ground current transformers.

Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.

PART VERIFICATION

Before You Order

Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.

01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS

From RFQ to Dispatch

1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ

Frequently Asked Questions

What does the DO designation mean on this relay?
The DO designation indicates a drawout model. It allows relay withdrawal without initiating a motor shutdown.
Which RTD sensor type does this unit accept?
The 100P option designates factory calibration for 100 Ohm platinum RTD temperature sensors.
Does this drawout relay comply with CE requirements?
Drawout versions of the GE Multilin 269 PLUS relay do not meet CE compliance.
What control power voltage does this unit require?
The relay operates with a control supply rating of 120 VAC or 125 VDC.
Condition Confirmed Before OrderQuoted condition is confirmed before payment and dispatch.
Warranty & Returns12 Months standard warranty and 30-day return request period.International DeliveryShipping method is selected according to destination and shipment size.
Technical Source PolicySpecifications are published only when supported by product or manufacturer references.
NEED THIS PART?

269PLUS-DO-271-100P-120

Send the quantity and destination country. We will confirm stock, condition, price and lead time.

Get Product Updates and Stock Availability Alerts

    REQUEST A QUOTE

    Check Price & Availability

    ProductGeneral Electric 269PLUS-DO-271-100P-120 Multilin Motor Management Relay
    Part Number: 269PLUS-DO-271-100P-120

      Request a Quote

      Send us the required quantity and destination. We will reply with current availability, lead time and final pricing.

      Home
      Products
      Account