HomeAllen-BradleyBlock I/O 1791I/O ModuleAllen-Bradley 1791-8BC Block I/O 1791 I/O Module
Allen-Bradley•I/O Module

Allen-Bradley 1791-8BC Block I/O 1791 I/O Module

Pricing
Request Pricing
Contact us for current price and availability.

The Allen-Bradley 1791-8BC Block I/O 1791 I/O Module provides combination discrete input and output functionality. It features eight 24 VDC discrete inputs and eight 24 VDC discrete outputs. The unit uses a rackless design that mounts on standard DIN rail. Communication occurs over Remote I/O networks using Belden 9463 or 1771-CD three-wire cable. Supported network transmission rates include 57.6K, 115.2K, and 230.4K baud.

ManufacturerAllen-Bradley
Part Number1791-8BC
Product TypeI/O Module
ConditionNew
Warranty12 Months
Lifecycle StatusRockwell Automation lists the 1791-8BC module status as discontinued and obsolete.
AvailabilityRequest current stock
12-Month Warranty30-Day Return Request WindowGlobal Shipping Support
✓
12 Months WarrantyCommercial warranty confirmed with quotation.
↩
30-Day Return RequestEligible returns subject to authorization.
✈
Worldwide ShippingCourier and freight options for international orders.
#
Part Number VerificationSend a label photo when suffix or revision is uncertain.
PRODUCT INFORMATION

Product Overview

The Allen-Bradley 1791-8BC Block I/O 1791 I/O Module provides combination discrete input and output functionality. It features eight 24 VDC discrete inputs and eight 24 VDC discrete outputs. The unit uses a rackless design that mounts on standard DIN rail. Communication occurs over Remote I/O networks using Belden 9463 or 1771-CD three-wire cable. Supported network transmission rates include 57.6K, 115.2K, and 230.4K baud.

External power requires a 19.2 to 30 VDC power supply with 300 mA maximum current draw. Both inputs and outputs operate across an operational voltage range of 10 to 30 VDC. Vertical mounting permits an output current of 500 mA at 60 degrees Celsius. Horizontal mounting provides 250 mA per point at 60 degrees Celsius. Internal thermal dissipation is rated at 11.8 watts and 41 BTU per hour.

TECHNICAL DATA

Technical Specifications

ParameterSpecification
CategoryPLCs
Current Draw300 mA, maximum
External Power19.2-30V dc
External Power supply19.2–30V dc
Input Off-state Current1.5mA min.
Input Off-state Voltage5V dc max.
Input On-state Current11mA @ 30V max.
Input On-state Voltage Range10-30V dc
Input signal, nominal24 VDC
Input signal, range10-30 VDC
Inputs per Block8
LED indicatorsIndividual channel LED indicators; OK LED;
No. of I/O channelsSixteen (16)
No. of Output channelsEight (8)
No. of input channelsEight (8)
Off-state current1.5mA
On state current11.0mA @ 30V, max; 2.5mA @ 10V, min.
Output Voltage Range10-30V dc
Output currentVertical mounting: 500mA @ 60oC, 1A @ 30oC Horizontal mounting: 250mA @ 60oC, 500mA @ 30oC
Output voltage10-30 VDC
Outputs per Block8
Product DescriptionCombination Discrete Input and Output Module
Product Lifecycle Status*Discontinued/Obsolete
UPC612598127085
Voltage24V dc
Weight2.00 lbs (0.91 kg)
TECHNICAL INFORMATION

Features

  • Eight discrete 24 VDC inputs arranged in a single group.
  • Eight discrete 24 VDC outputs operating between 10 and 30 VDC.
  • Rackless hardware structure supporting direct DIN rail mounting.
  • Remote I/O transmission rates of 57.6K, 115.2K, and 230.4K baud.
  • Individual channel status indicators and an overall OK LED indicator.
  • Low thermal dissipation rated at 11.8 watts and 41 BTU per hour.
TECHNICAL INFORMATION

Applications

  • Distributed machine-level discrete sensor and actuator interfacing.
  • Remote I/O drops for PLC-5 and SLC 500 controller networks.
  • Logix platform field I/O expansion via Remote I/O communication modules.
TECHNICAL INFORMATION

Connections / Interfaces

  • Remote I/O connects to terminals 6 (BLU), 7 (SHD), and 8 (CLR).
  • The network uses Belden 9463 or 1771-CD three-wire communication cable.
  • Terminating resistors connect across terminals 6 and 8 on endpoint nodes.
  • Use 150-ohm terminating resistors for 57.6K and 115.2K baud rates.
  • Use 82-ohm terminating resistors for 230.4K baud communication.
  • Terminal connections accept up to 14 AWG stranded wire with 3/64 inch insulation.
TECHNICAL INFORMATION

Installation Guidelines

  1. Mount the module on standard DIN rail in a distributed enclosure.
  2. Vertical mounting supports up to 500 mA output current at 60 degrees Celsius.
  3. Horizontal mounting derates maximum output current to 250 mA at 60 degrees Celsius.
  4. Connect an external 19.2 to 30 VDC power supply to the unit.
TECHNICAL INFORMATION

Compatibility

  • Allen-Bradley PLC-2 and PLC-3 control platforms.
  • Allen-Bradley 1785 PLC-5 controller systems.
  • Allen-Bradley 1747 SLC 500 systems via Remote I/O scanners.
  • CompactLogix and ControlLogix systems using Remote I/O communication modules.
TECHNICAL INFORMATION

Lifecycle / Replacement Information

  • Rockwell Automation lists the 1791-8BC module status as discontinued and obsolete.
COMPATIBILITY

Compatibility & Replacement

COMPATIBLE MODELSAllen-Bradley PLC-2 and PLC-3 control platforms. Allen-Bradley 1785 PLC-5 controller systems. Allen-Bradley 1747 SLC 500 systems via Remote I/O scanners. CompactLogix and ControlLogix systems using Remote I/O communication modules.

Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.

PART VERIFICATION

Before You Order

Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.

01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS

From RFQ to Dispatch

1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ

Frequently Asked Questions

What communication protocol does the 1791-8BC module use?
The module uses Remote I/O communication at 57.6K, 115.2K, or 230.4K baud over three-wire cable.
What input and output configurations are available on the 1791-8BC?
The module provides eight 24 VDC inputs and eight 24 VDC outputs operating from 10 to 30 VDC.
How does mounting orientation affect the output current rating?
Vertical mounting allows 500 mA at 60 degrees Celsius. Horizontal mounting lowers the rating to 250 mA.
What termination resistors are needed on the Remote I/O network?
Install 150-ohm resistors for 57.6K or 115.2K baud. Install 82-ohm resistors across terminals 6 and 8 for 230.4K baud.
Condition Confirmed Before OrderQuoted condition is confirmed before payment and dispatch.
Warranty & Returns12 Months standard warranty and 30-day return request period.International DeliveryShipping method is selected according to destination and shipment size.
Technical Source PolicySpecifications are published only when supported by product or manufacturer references.
NEED THIS PART?

1791-8BC

Send the quantity and destination country. We will confirm stock, condition, price and lead time.

Get Product Updates and Stock Availability Alerts

    REQUEST A QUOTE

    Check Price & Availability

    ProductAllen-Bradley 1791-8BC Block I/O 1791 I/O Module
    Part Number: 1791-8BC

      Request a Quote

      Send us the required quantity and destination. We will reply with current availability, lead time and final pricing.

      Home
      Products
      Account