PRODUCT INFORMATION
Product Overview
The General Electric IC200ALG260 VersaMax Analog Input Module provides eight single-ended input channels. The module accepts unipolar 0 to 10 VDC signals. It also handles bipolar +/-10 VDC voltage inputs. Additionally, the unit processes standard 4 to 20 mA current loops. Input signals are digitized with 12 bits of conversion resolution. The module draws operating power directly from the VersaMax backplane. It requires no external field power supply for standard operation. Backplane power consumption is rated at 125 mA at 5 VDC.
Optical isolation protects sensitive backplane circuits at 250 VAC continuous and 1500 VAC for one minute. The hardware incorporates two front-panel LED indicators named OK and INT PWR. Internal diagnostic circuitry detects loss of internal power. Field measurements reference a common ground connection across all eight single-ended channels. Software configuration defines range selection and mode selection per application requirements. On module communication error, the device holds the last state or returns to a pre-defined value.
TECHNICAL DATA
Technical Specifications
| Parameter | Specification |
|---|
| Weight | 0.63 lbs (0.28 kg) |
|---|
| Product Description | Analog input module |
|---|
| Number of Inputs | 8 |
|---|
| No of Channels | Eight (8) analog input |
|---|
| Input Type | Single-Ended |
|---|
| Analog input signal | Analog input signal |
|---|
| LED Indicators | 2 (The "OK" and the "INT PWR" LED |
|---|
| Analog input resolution | 12 bits |
|---|
| Voltage Type | Unipolar or Bipolar |
|---|
| Response times | 5.0 ms |
|---|
| Operating Modes | Voltage or Current |
|---|
| Update rate | 0.4 ms |
|---|
| Filter Response Time | 5 milliseconds |
|---|
| Backplane current consumption | 125 mA at 5VDC |
|---|
| Configuration parameters | Range select, Mode select |
|---|
| Diagnostics | Loss of internal power |
|---|
| Reaction to module error | Hold last state; Go to pre-defined value |
|---|
| Optical isolation | 250VAC continuous; 1500VAC for 1 minute |
|---|
TECHNICAL INFORMATION
Features
- Provides eight single-ended analog input channels arranged in one common group.
- Supports configurable 0 to 10 VDC, +/-10 VDC, and 4 to 20 mA signal ranges.
- Delivers 12-bit digital resolution across all operating input ranges.
- Supplies 250 VAC continuous and 1500 VAC one-minute optical backplane isolation.
- Features diagnostic LED indicators for internal field power and backplane communication status.
- Includes configurable fault reaction modes to hold the last state or apply pre-defined values.
- Draws operating current directly from the VersaMax backplane without external logic power.
TECHNICAL INFORMATION
Applications
- VersaMax PLC systems monitoring industrial voltage transmitters and current loops.
- Single-ended analog signal acquisition in machine automation and process control panels.
TECHNICAL INFORMATION
Connections / Interfaces
- All eight analog inputs utilize a single-ended configuration sharing a common reference wire.
- Input impedance measures 126 kOhms in voltage mode and 200 Ohms in current mode.
- Backplane connection supplies up to 130 mA at 5 VDC logic power.
TECHNICAL INFORMATION
Installation Guidelines
- Seat the module securely onto a compatible VersaMax I/O carrier before applying backplane power.
- Provide external noise cancellation and signal conditioning because single-ended wiring has reduced EMI resistance.
- Verify that transceiver devices have separate external power if deployed with current loops.
TECHNICAL INFORMATION
Configuration Guidelines
- Configure channel mode selection between voltage mode and 4 to 20 mA current mode.
- Select unipolar 0 to 10 VDC or bipolar +/-10 VDC ranges in voltage configuration.
- Define module fault behavior to maintain last state or adopt default values upon communication errors.
TECHNICAL INFORMATION
Compatibility
- Mounts on standard GE VersaMax I/O carriers within VersaMax PLC racks.
COMPATIBILITY
Compatibility & Replacement
COMPATIBLE MODELSMounts on standard GE VersaMax I/O carriers within VersaMax PLC racks.
Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.
PART VERIFICATION
Before You Order
Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.
01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS
From RFQ to Dispatch
1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ
Frequently Asked Questions
What signal types does the IC200ALG260 module accept?
The IC200ALG260 accepts unipolar 0 to 10 VDC, bipolar +/-10 VDC, and 4 to 20 mA signals.
Does the IC200ALG260 require an external logic power supply?
No, the module derives its operating logic power directly from the VersaMax backplane.
What is the conversion resolution of the IC200ALG260?
The module converts all configured analog input signals with 12-bit resolution.
What status indicators are present on the IC200ALG260 faceplate?
The module provides two LEDs: OK indicates backplane power and INT PWR indicates internal field power.