HomeGeneral ElectricPACSystems RX3iDeviceNet Master ModuleGeneral Electric IC694DNM200 PACSystems RX3i DeviceNet Master Module
General Electric•DeviceNet Master Module

General Electric IC694DNM200 PACSystems RX3i DeviceNet Master Module

Pricing
Request Pricing
Contact us for current price and availability.

The General Electric IC694DNM200 is a DeviceNet Master Module designed for the PACSystems RX3i controller platform. It connects a host RX3i central processing unit to distributed devices over a standard DeviceNet fieldbus network. This communication module mounts in a universal baseplate and draws operating power directly from the backplane. The module can control up to 63 DeviceNet slave devices across trunkline or dropline topologies. It handle

ManufacturerGeneral Electric
Part NumberIC694DNM200
Product TypeDeviceNet Master Module
ConditionNew
Warranty12 Months
Lifecycle StatusThe IC694DNM200 module has reached discontinued and obsolete lifecycle status from the manufacturer. Spare units remain available through specialized automation distributors to maintain legacy operating systems.
AvailabilityRequest current stock
12-Month Warranty30-Day Return Request WindowGlobal Shipping Support
✓
12 Months WarrantyCommercial warranty confirmed with quotation.
↩
30-Day Return RequestEligible returns subject to authorization.
✈
Worldwide ShippingCourier and freight options for international orders.
#
Part Number VerificationSend a label photo when suffix or revision is uncertain.
PRODUCT INFORMATION

Product Overview

The General Electric IC694DNM200 is a DeviceNet Master Module designed for the PACSystems RX3i controller platform. It connects a host RX3i central processing unit to distributed devices over a standard DeviceNet fieldbus network. This communication module mounts in a universal baseplate and draws operating power directly from the backplane. The module can control up to 63 DeviceNet slave devices across trunkline or dropline topologies. It handles maximum data throughput of 3972 bytes of input and 3972 bytes of output.

This module supports configurable communication rates of 125k, 250k, and 500k baud. Each configured slave station exchanges up to 255 bytes of input data and 255 bytes of output data. Supported connection types include Polled, Cyclic, Strobe, and Change of State messaging. It also accommodates Unconnected Message Manager operations with one proxy connection per slave. The hardware features a dedicated DeviceNet terminal port alongside an RS232 service port for firmware maintenance.

TECHNICAL DATA

Technical Specifications

ParameterSpecification
Weight0.69 lbs (0.31 kg)
Product DescriptionDeviceNet Master Module
Communication interfaceOne (1) RS232 Service port; One (1) DeviceNet Master Port
Communication protocolDeviceNet
Maximum Number of Slave Devices Supported63
No. of supported DeviceNet slave63
Slave OperationSupported
Input data255 Bytes
Communication Rates125k, 250k, or 500k bauds
Output data255 Bytes
Maximum Load (5 Volts DC)450 milliamps or 2.25 Watts
Baud rates125k, 250k, or 500k
Compatible RX3i CPUsVersion 3.5 or Later
Mounting locationRx3i and Series 90-30 Backplane
Configurable Global Scan RateSupported
RedundancyNot supported
Network Power for Node devices24VDC +/- 4%
Diagnostic Address DetectionDuring power-up
Current draw450mA @ 5VDC
Product Lifecycle StatusDiscontinued/Obsolete
TECHNICAL INFORMATION

Features

  • Controls up to 63 DeviceNet slave devices across distributed fieldbus networks.
  • Provides selectable communication baud rates of 125k, 250k, and 500k baud.
  • Transfers up to 255 bytes of input and 255 bytes of output data per slave.
  • Supports Polled, Cyclic, Strobe, and Change of State connection types.
  • Integrates an RS232 service port for local firmware upgrades.
  • Enables simultaneous operation as a master device and a slave to another master.
TECHNICAL INFORMATION

Applications

  • Interfacing PACSystems RX3i controllers with distributed industrial sensors and limit switches.
  • Connecting motor starters and variable frequency drives over DeviceNet networks.
  • Exchanging operational data with remote operator interface terminals and control panels.
TECHNICAL INFORMATION

Connections / Interfaces

  • One removable DeviceNet master terminal supporting thick and thin trunkline or dropline cables.
  • Cabling requires a common axis configuration with a central drain wire.
  • One dedicated RS232 serial service port for performing module firmware upgrades.
TECHNICAL INFORMATION

Installation Guidelines

  1. Install the module into any available I/O slot of an RX3i universal backplane.
  2. Module mounting is also supported in compatible Series 90-30 baseplates.
  3. Do not install this module into remote expansion backplanes or expansion racks.
  4. Never perform hot insertion or hot removal while the baseplate power is active.
  5. The DeviceNet fieldbus connector can be detached without disrupting continuous bus operations.
TECHNICAL INFORMATION

Configuration Guidelines

  1. Requires a PACSystems RX3i central processing unit running firmware version 3.5 or later.
  2. Define network baud rates at 125k, 250k, or 500k baud to match connected nodes.
  3. Configure individual node scan rates and connection types using compatible system software tools.
TECHNICAL INFORMATION

Compatibility

  • PACSystems RX3i CPUs running firmware version 3.5 or later.
  • PACSystems RX3i universal backplanes.
  • Series 90-30 baseplates.
  • Standard DeviceNet slave devices compliant with ODVA specifications.
TECHNICAL INFORMATION

Lifecycle / Replacement Information

  • The IC694DNM200 module has reached discontinued and obsolete lifecycle status from the manufacturer.
  • Spare units remain available through specialized automation distributors to maintain legacy operating systems.
COMPATIBILITY

Compatibility & Replacement

COMPATIBLE MODELSPACSystems RX3i CPUs running firmware version 3.5 or later. PACSystems RX3i universal backplanes. Series 90-30 baseplates. Standard DeviceNet slave devices compliant with ODVA specifications.

Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.

PART VERIFICATION

Before You Order

Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.

01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS

From RFQ to Dispatch

1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ

Frequently Asked Questions

Which CPU versions support the IC694DNM200 module?
The module requires a PACSystems RX3i CPU running firmware version 3.5 or later.
Can the IC694DNM200 be installed in expansion racks?
No. It must reside in a universal backplane and cannot be placed in expansion racks.
Does the IC694DNM200 support hot swapping during operation?
No. The module does not support hot insertion or hot removal while powered.
Condition Confirmed Before OrderQuoted condition is confirmed before payment and dispatch.
Warranty & Returns12 Months standard warranty and 30-day return request period.International DeliveryShipping method is selected according to destination and shipment size.
Technical Source PolicySpecifications are published only when supported by product or manufacturer references.
NEED THIS PART?

IC694DNM200

Send the quantity and destination country. We will confirm stock, condition, price and lead time.

Get Product Updates and Stock Availability Alerts

    REQUEST A QUOTE

    Check Price & Availability

    ProductGeneral Electric IC694DNM200 PACSystems RX3i DeviceNet Master Module
    Part Number: IC694DNM200

      Request a Quote

      Send us the required quantity and destination. We will reply with current availability, lead time and final pricing.

      Home
      Products
      Account