PRODUCT INFORMATION
Product Overview
The General Electric IC697CBL811 is a specialized redundant cable for Series 90-70 programmable logic controllers. This connection cable measures 10 feet in length. It provides direct interconnectivity to support Redundancy Communication Module RCM operations in redundant PLC configurations. The unit functions as a dedicated hardware accessory within the Series 90-70 control architecture.
The cable is engineered to operate in environments from 0 to 40 degrees Celsius. Permissible non-condensing relative operating humidity levels extend up to 80 percent. Storage temperature tolerance spans from 0 to 50 degrees Celsius for warehouse holding. The cable operates at elevations up to 1000 meters above sea level in industrial facilities.
TECHNICAL DATA
Technical Specifications
| Parameter | Specification |
|---|
| Spare Part/Accessory | Yes |
|---|
| Length | 10 Feet |
|---|
| RCM Communication | Supported |
|---|
| PLC Applications | Supported |
|---|
| Min. Operating Temperature | 0 degrees Celsius |
|---|
| Max. Operating Temperature | 40 degrees Celsius |
|---|
| Min. Storage Temperature | 0 degrees Celsius |
|---|
| Max. Storage Temperature | 50 degrees Celsius |
|---|
| Max. Relative Operating Humidity | 80%, non-condensing |
|---|
| Max. Altitude | 1000m above sea level |
|---|
TECHNICAL INFORMATION
Features
- Designed specifically for General Electric Series 90-70 PLC redundant systems.
- Provides a standard length of 10 feet for control cabinet interconnects.
- Supports high-integrity Redundancy Communication Module communication.
- Rated for operation up to 1000 meters above sea level.
- Permits non-condensing relative operating humidity up to 80 percent.
TECHNICAL INFORMATION
Applications
- Series 90-70 redundant processor communication links.
- Cabinet-to-cabinet Redundancy Communication Module interconnections.
- Redundant programmable logic controller architectures.
TECHNICAL INFORMATION
Connections / Interfaces
- Direct RCM communication interface connection for Series 90-70 hardware.
- Pre-terminated 10-foot cable assembly designed for dedicated redundancy modules.
TECHNICAL INFORMATION
Installation Guidelines
- Verify that system power is deactivated before connecting the cable between redundancy modules.
- Route the 10-foot cable away from high-voltage power conduits to minimize noise.
- Ensure environmental operating temperatures stay between 0 and 40 degrees Celsius.
TECHNICAL INFORMATION
Configuration Guidelines
- Configure redundancy communication parameters through the programming software according to system specifications.
- Confirm communication status on the Redundancy Communication Module indicators after system boot.
TECHNICAL INFORMATION
Compatibility
- Compatible with General Electric Series 90-70 Redundancy Communication Modules.
- Designed specifically for Series 90-70 PLC hardware architectures.
TECHNICAL INFORMATION
Lifecycle / Replacement Information
- Available as a replacement accessory for existing General Electric Series 90-70 installations.
COMPATIBILITY
Compatibility & Replacement
COMPATIBLE MODELSCompatible with General Electric Series 90-70 Redundancy Communication Modules. Designed specifically for Series 90-70 PLC hardware architectures.
Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.
PART VERIFICATION
Before You Order
Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.
01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS
From RFQ to Dispatch
1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ
Frequently Asked Questions
What is the function of the General Electric IC697CBL811 cable?
The IC697CBL811 provides redundant communication linking for Redundancy Communication Modules within Series 90-70 PLC systems.
What is the physical length of the IC697CBL811 redundant cable?
The IC697CBL811 cable has an exact pre-assembled length of 10 feet.
What operating environmental limits apply to the IC697CBL811?
The cable operates from 0 to 40 degrees Celsius up to 80 percent non-condensing relative humidity. It functions at altitudes up to 1000 meters above sea level.