HomeAllen-BradleySLC 500Analog Input ModuleAllen-Bradley 1746-NT8 SLC 500 Analog Input Module
Allen-Bradley•Analog Input Module

Allen-Bradley 1746-NT8 SLC 500 Analog Input Module

Pricing
Request Pricing
Contact us for current price and availability.

The Allen-Bradley 1746-NT8 is an SLC 500 Analog Input Module designed for temperature and low-voltage signal monitoring. It provides eight input channels for connecting thermocouple and millivolt sensors. The module converts analog signals to digital values using sigma-delta modulation. Converted data is stored in local memory and retrieved by SLC 500 processors. It installs into standard modular chassis or the 1746-A2 fixed expansion chassis.

ManufacturerAllen-Bradley
Part Number1746-NT8
Product TypeAnalog Input Module
ConditionNew
Warranty12 Months
AvailabilityRequest current stock
12-Month Warranty30-Day Return Request WindowGlobal Shipping Support
✓
12 Months WarrantyCommercial warranty confirmed with quotation.
↩
30-Day Return RequestEligible returns subject to authorization.
✈
Worldwide ShippingCourier and freight options for international orders.
#
Part Number VerificationSend a label photo when suffix or revision is uncertain.
PRODUCT INFORMATION

Product Overview

The Allen-Bradley 1746-NT8 is an SLC 500 Analog Input Module designed for temperature and low-voltage signal monitoring. It provides eight input channels for connecting thermocouple and millivolt sensors. The module converts analog signals to digital values using sigma-delta modulation. Converted data is stored in local memory and retrieved by SLC 500 processors. It installs into standard modular chassis or the 1746-A2 fixed expansion chassis.

The unit draws 120 mA at 5V DC and 70 mA at 24V DC from the backplane. Total maximum backplane power consumption is 2.28 W during operation. Input overvoltage protection is rated at plus or minus 30V DC and 600W pulsed. Field devices connect through the 1746-RT34 removable terminal block. The terminal block includes two cold-junction compensation sensors for thermal accuracy. Nine front green LEDs indicate channel status and operational health.

TECHNICAL DATA

Technical Specifications

ParameterSpecification
A/D Conversion methodSigma-delta modulation
Backplane Current120 mA @ 5VDC; 70 mA @ 24VDC
Backplane Current (24 Volts)70 milliamps
Backplane Current (5 Volts)120 milliamps
Backplane Power Consumption2.28W maximum (0.6W at 5V dc, 1.68W at 24V dc)
CategoryPLCs
Compatible Thermocouple SensorsJ, K, T, E, S, R, B and N
Compatible miliVolt signal+/- 50 mV and +/- 100 mV
I/O Chassis locationAny slot except Slot 0
Inputs8
Module TypeThermocouple/mV Analog Input Module
No. of InputsEight (8)
Open Circuit DetectionZero; Upscale; Downscale
Operating Temperature0 to 60 degrees Celsius
Resolution16 bits in, 14 bits out
Step Response60 milliseconds in, 2.5 milliseconds out
Storage Temperature-40 to 85 degrees Celsius
UPC611320130881
Update Time356 milliseconds-4.05 seconds
Weight0.63 lbs (0.28 kg)
TECHNICAL INFORMATION

Features

  • Eight chassis-installed input channels receive thermocouple and millivolt signals.
  • Sigma-delta analog-to-digital conversion provides 16-bit input and 14-bit output resolution.
  • Automatic self-calibration occurs approximately every two minutes after system power-up.
  • Supports thermocouple types J, K, T, E, S, R, B, and N.
  • Accepts DC millivolt signal ranges of plus or minus 50 mV and 100 mV.
  • Nine green LED status indicators show individual channel activity and module status.
  • Digital low-pass filter provides selectable programmable filter frequency settings.
  • Normal mode and common mode rejection ratings exceed 100 dB at 50 to 60 Hz.
TECHNICAL INFORMATION

Applications

  • Direct thermocouple temperature signal monitoring across SLC 500 automation systems.
  • Low-voltage millivolt sensor signal acquisition within modular 1746 chassis architectures.
  • Thermal data acquisition for PID loop control using SLC 500 controllers.
TECHNICAL INFORMATION

Connections / Interfaces

  • Field wiring connects to the 1746-RT34 removable terminal block.
  • Two cold-junction compensation sensors provide measurement accuracy within plus or minus 1.72 degrees Celsius.
  • Connected field input devices must have an impedance under 100 Ohms to maintain rated accuracy.
  • Overall module input impedance exceeds 10 M Ohms.
TECHNICAL INFORMATION

Installation Guidelines

  1. Mount the module in any chassis slot except slot 0.
  2. Slot 0 is reserved exclusively for SLC 500 processors or communication adapters.
  3. Compatible chassis include modular 1746 enclosures and the 1746-A2 fixed expansion chassis.
TECHNICAL INFORMATION

Configuration Guidelines

  1. Available data formats include engineering units, Scaled for PID, and Proportional counts.
  2. Scaled for PID is the primary format used with thermocouple and millivolt inputs.
  3. Open-circuit detection offers selectable zero, upscale, or downscale response behavior.
  4. Diagnostic bits indicate channel error, open-circuit, under-range, and over-range conditions.
TECHNICAL INFORMATION

Compatibility

  • Compatible with SLC 5/01, SLC 5/02, SLC 5/03, SLC 5/04, and SLC 5/05 processors.
  • Installs into SLC 500 modular chassis and 1746-A2 fixed style expansion chassis.
TECHNICAL INFORMATION

Compliance and Certifications

  • UL approved.
  • CUL approved.
COMPATIBILITY

Compatibility & Replacement

COMPATIBLE MODELSCompatible with SLC 5/01, SLC 5/02, SLC 5/03, SLC 5/04, and SLC 5/05 processors. Installs into SLC 500 modular chassis and 1746-A2 fixed style expansion chassis.

Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.

PART VERIFICATION

Before You Order

Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.

01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS

From RFQ to Dispatch

1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ

Frequently Asked Questions

Which sensor types connect directly to the 1746-NT8 module?
The 1746-NT8 supports thermocouple types J, K, T, E, S, R, B, and N. It also accepts DC signals of plus or minus 50 mV and 100 mV.
Which chassis slots accept the 1746-NT8 analog input module?
The module installs into any chassis slot except slot 0. Slot 0 is strictly reserved for processors or communication adapters.
What terminal block is required for connecting field wiring?
Wiring connects through the 1746-RT34 removable terminal block. It includes two cold-junction compensation sensors for accurate temperature measurements.
What data formats are supported by the 1746-NT8?
Supported data formats include engineering units, Scaled for PID, and Proportional counts. Scaled for PID is standard for temperature signals.
Condition Confirmed Before OrderQuoted condition is confirmed before payment and dispatch.
Warranty & Returns12 Months standard warranty and 30-day return request period.International DeliveryShipping method is selected according to destination and shipment size.
Technical Source PolicySpecifications are published only when supported by product or manufacturer references.
NEED THIS PART?

1746-NT8

Send the quantity and destination country. We will confirm stock, condition, price and lead time.

Get Product Updates and Stock Availability Alerts

    REQUEST A QUOTE

    Check Price & Availability

    ProductAllen-Bradley 1746-NT8 SLC 500 Analog Input Module
    Part Number: 1746-NT8

      Request a Quote

      Send us the required quantity and destination. We will reply with current availability, lead time and final pricing.

      Home
      Products
      Account