PRODUCT INFORMATION
Product Overview
The Allen-Bradley 1746-OX8 SLC 500 Output Module provides discrete control for industrial automation systems. It features eight individually isolated relay outputs. Each point provides electrical isolation across separate load circuits. The hardware supports operating voltages across diverse AC and DC control circuits. It accommodates 5 to 125V DC at 5 volts and 5 to 265V at 24 volts.
The module integrates a removable terminal block to simplify wiring and field servicing. Each relay output delivers a maximum signal delay of 10 milliseconds. The hardware withstands a maximum operating shock rating of 10 G. Total thermal dissipation reaches 8.6 Watts, with 0.825 Watts generated per output point. Minimum heat dissipation equals 2.59 Watts.
TECHNICAL DATA
Technical Specifications
| Parameter | Specification |
|---|
| Applications in Hazardous Locations | Supported in Class 1, Division 2 types of hazardous locations |
|---|
| GTIN | 10662073896620 |
|---|
| Heat Dissipation per Point | 0.825 Watts |
|---|
| Individually Isolated Outputs | Yes |
|---|
| Maximum Operating Shock | 10 G |
|---|
| Maximum Signal Delay | 10 ms (on or off) |
|---|
| Minimum Heat Dissipation | 2.59 Watts |
|---|
| Number of Outputs | 8 Outputs |
|---|
| Operating Voltage at 24V DC | 5 to 265V |
|---|
| Operating Voltage at 5V DC | 5 to 125V |
|---|
| Output Type | Relay Outputs |
|---|
| Terminal Block Type | Removable Terminal Block |
|---|
| Total Heat Dissipation | 8.6 Watts |
|---|
| UPC | 662073896623 |
|---|
| Voltage Category | AC/DC Relay Category |
|---|
| Weight | 0.75 lbs (0.34 kg) |
|---|
TECHNICAL INFORMATION
Features
- Eight individually isolated electromechanical relay contact outputs
- Removable terminal block for simplified wiring and replacement
- Supports operating voltages from 5 to 125V DC and 5 to 265V AC/DC
- Maximum signal transition delay of 10 ms for on and off states
- Operating mechanical shock resistance rated up to 10 G
- Class 1, Division 2 hazardous location classification support
- Thermal dissipation of 0.825 Watts per point and 8.6 Watts total
TECHNICAL INFORMATION
Applications
- Class 1, Division 2 hazardous location industrial automation
- Isolated AC and DC load switching in SLC 500 rack configurations
- Discrete actuator, solenoid, and pilot indicator control
TECHNICAL INFORMATION
Connections / Interfaces
- Removable terminal block allows pre-wiring before module insertion.
- Eight isolated relay contact circuits connect to individual field load loops.
TECHNICAL INFORMATION
Installation Guidelines
- Mount the module into any available slot in a compatible SLC 500 chassis.
- Tighten terminal block screws securely to prevent loose wiring connections.
- Verify that system enclosure shock levels do not exceed the 10 G rating.
TECHNICAL INFORMATION
Compatibility
- Compatible with standard Allen-Bradley SLC 500 chassis and processor racks.
TECHNICAL INFORMATION
Compliance and Certifications
- Approved for use in Class 1, Division 2 hazardous locations.
COMPATIBILITY
Compatibility & Replacement
COMPATIBLE MODELSCompatible with standard Allen-Bradley SLC 500 chassis and processor racks.
Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.
PART VERIFICATION
Before You Order
Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.
01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS
From RFQ to Dispatch
1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ
Frequently Asked Questions
What is the output configuration of the 1746-OX8 module?
The module provides eight individually isolated relay outputs for AC and DC load switching.
What is the maximum signal delay for the 1746-OX8 relay points?
Each relay point has a maximum signal delay of 10 milliseconds for both turn-on and turn-off transitions.
Can the 1746-OX8 operate in hazardous industrial locations?
Yes, the 1746-OX8 supports deployment in environments classified as Class 1, Division 2 hazardous locations.
What is the total heat dissipation of the 1746-OX8 module?
Total heat dissipation reaches 8.6 Watts, with minimum dissipation specified at 2.59 Watts.