HomeAllen-BradleySLC 500Processor ModuleAllen-Bradley 1747-L541 SLC 500 Processor Module
Allen-Bradley•Processor Module

Allen-Bradley 1747-L541 SLC 500 Processor Module

Pricing
Request Pricing
Contact us for current price and availability.

The Allen-Bradley 1747-L541 is an SLC 500 processor module in the SLC 5/04 controller family. It features 16K words of integrated user memory for industrial ladder logic execution. The unit addresses up to 4,096 digital inputs and 4,096 digital outputs. System capacity supports up to 480 analog input and output channels. It controls up to 30 local slots distributed across three chassis.

ManufacturerAllen-Bradley
Part Number1747-L541
Product TypeProcessor Module
ConditionNew
Warranty12 Months
AvailabilityRequest current stock
12-Month Warranty30-Day Return Request WindowGlobal Shipping Support
✓
12 Months WarrantyCommercial warranty confirmed with quotation.
↩
30-Day Return RequestEligible returns subject to authorization.
✈
Worldwide ShippingCourier and freight options for international orders.
#
Part Number VerificationSend a label photo when suffix or revision is uncertain.
PRODUCT INFORMATION

Product Overview

Revision scope: These specifications describe 1747-L541/B (Series B). Check the corresponding technical data before specifying another hardware series.

The Allen-Bradley 1747-L541 is an SLC 500 processor module in the SLC 5/04 controller family. It features 16K words of integrated user memory for industrial ladder logic execution. The unit addresses up to 4,096 digital inputs and 4,096 digital outputs. System capacity supports up to 480 analog input and output channels. It controls up to 30 local slots distributed across three chassis.

Built-in communication ports include Data Highway Plus and RS-232 serial interfaces. The processor delivers a typical program scan rate of 0.9 ms per kiloword. Bit execution requires 0.37 microseconds for basic examine instructions. The backplane current draw requires 1,000 mA at 5V DC and 200 mA at 24V DC. An optional 1747-M13 memory module provides 64 KB of flash backup storage.

TECHNICAL DATA

Technical Specifications

These specifications describe 1747-L541/B (Series B). Check the corresponding technical data before specifying another hardware series.

ParameterSpecification
SpecificationValue
Series / FamilyAllen-Bradley SLC 500 / SLC 5/04
User Memory16K Words
Flash Backup Memory64 KB (via 1747-M13 memory module)
Maximum Digital I/O4,096 Inputs / 4,096 Outputs (8,192 total)
Maximum Analog I/O480 Points
Communication PortsData Highway Plus (DH+), RS-232
Backplane Current Draw1,000 mA @ 5V DC; 200 mA @ 24V DC
Typical Scan Time0.9 ms/K
Bit Execution Time (XIC)0.37 microseconds
Selectable Timed Interrupt (STI)1 ms minimum
Discrete Input Interrupt (DII)0.5 ms
Local Chassis / Max Slots3 Chassis / 30 Slots
Power Hold-Up Time20 ms to 3 seconds (load dependent)
Minimum Thermal Dissipation4 W
Mounting StyleRack Mount (SLC 500 backplane)
Programming SoftwareRSLogix 500
WeightApprox. 2.09 lbs (0.95 kg)
CertificationsUL Listed (US and Canada), CE, C-Tick
TECHNICAL INFORMATION

Order Information

Revision Part #Also known asReference Price
1747-L541 Ser B1747-L541/B, Series BUSD 359.00, indicative (Used/Refurbished)
1747-L541 Ser C1747-L541/C, Series CUSD 459.00, indicative (Used/Refurbished)
1747-L541 Ser D1747-L541/D, Series D

Reference prices are observed third-party market prices for the stated revision, not a final Aituos quotation.

TECHNICAL INFORMATION

Features

  • Provides 16K words of user program memory.
  • Supports up to 30 module slots across three local chassis.
  • Includes integrated Data Highway Plus and RS-232 communication ports.
  • Offers flash backup memory up to 64 KB using the 1747-M13 module.
  • Delivers 0.37 microsecond bit execution speed for contact instructions.
  • Executes selectable timed interrupts down to 1 millisecond.
TECHNICAL INFORMATION

Connections / Interfaces

  • Data Highway Plus port supports networking across DH+ peer links.
  • RS-232 port supports serial communication and programming connections.
  • Backplane edge connector interfaces with SLC 500 chassis slots.
TECHNICAL INFORMATION

Installation Guidelines

  1. Install the processor in slot 0 of the first SLC 500 chassis.
  2. Disconnect all chassis power before inserting or removing the processor module.
  3. Engage the top and bottom retaining latches to secure the module.
  4. Ensure the chassis backplane has a proper protective earth ground connection.
TECHNICAL INFORMATION

Configuration Guidelines

  1. Configure module settings and write ladder logic using RSLogix 500 software.
  2. Set the DH+ station address and transmission rate in the controller project.
  3. Install the 1747-M13 memory module for non-volatile program backup.
TECHNICAL INFORMATION

Compatibility

  • Compatible with Allen-Bradley SLC 500 modular chassis.
  • Operates with SLC 500 discrete and analog input and output modules.
  • Supported by Rockwell Software RSLogix 500 programming environments.
TECHNICAL INFORMATION

Compliance and Certifications

  • UL Listed for the United States and Canada.
  • CE compliant for applicable European standards.
  • C-Tick compliant for Australia and New Zealand.
COMPATIBILITY

Compatibility & Replacement

COMPATIBLE MODELSCompatible with Allen-Bradley SLC 500 modular chassis. Operates with SLC 500 discrete and analog input and output modules. Supported by Rockwell Software RSLogix 500 programming environments.

Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.

PART VERIFICATION

Before You Order

Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.

01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS

From RFQ to Dispatch

1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ

Frequently Asked Questions

What communication interfaces are included on the Allen-Bradley 1747-L541?
The module includes one Data Highway Plus port and one RS-232 serial communication port.
What is the memory capacity of the 1747-L541 processor?
The processor contains 16K words of user memory and supports optional 64 KB flash backup.
Which programming software supports the 1747-L541 controller?
Rockwell Software RSLogix 500 programming software supports configuration and programming for this module.
What is the market reference price for the 1747-L541?
Observed market reference pricing is USD 359.00 for refurbished units. These figures are indicative market reference pricing only and not a final quotation.
Condition Confirmed Before OrderQuoted condition is confirmed before payment and dispatch.
Warranty & Returns12 Months standard warranty and 30-day return request period.International DeliveryShipping method is selected according to destination and shipment size.
Technical Source PolicySpecifications are published only when supported by product or manufacturer references.
NEED THIS PART?

1747-L541

Send the quantity and destination country. We will confirm stock, condition, price and lead time.

Get Product Updates and Stock Availability Alerts

    REQUEST A QUOTE

    Check Price & Availability

    ProductAllen-Bradley 1747-L541 SLC 500 Processor Module
    Part Number: 1747-L541

      Request a Quote

      Send us the required quantity and destination. We will reply with current availability, lead time and final pricing.

      Home
      Products
      Account