The Allen-Bradley 1756-L62 is a ControlLogix Processor Module. It features 4 MB of integrated user memory and 478 KB of I/O memory. The module handles up to 128,000 total digital I/O points and 4,000 analog I/O points. It mounts directly into 1756 chassis including 1756-A4, 1756-A7, 1756-A10, 1756-A13, and 1756-A17.

ManufacturerAllen-Bradley
Part Number1756-L62
Product TypeProcessor Module
ConditionNew
Warranty12 Months
Lifecycle StatusThe 1756-L62 controller entered discontinued lifecycle status on June 01, 2017. The designated functional replacement model is the 1756-L72 processor.
AvailabilityRequest current stock
12-Month Warranty30-Day Return Request WindowGlobal Shipping Support
✓
12 Months WarrantyCommercial warranty confirmed with quotation.
↩
30-Day Return RequestEligible returns subject to authorization.
✈
Worldwide ShippingCourier and freight options for international orders.
#
Part Number VerificationSend a label photo when suffix or revision is uncertain.
PRODUCT INFORMATION

Product Overview

The Allen-Bradley 1756-L62 is a ControlLogix Processor Module. It features 4 MB of integrated user memory and 478 KB of I/O memory. The module handles up to 128,000 total digital I/O points and 4,000 analog I/O points. It mounts directly into 1756 chassis including 1756-A4, 1756-A7, 1756-A10, 1756-A13, and 1756-A17.

This controller supports up to 32 tasks with 100 programs per task. An onboard RS-232 serial port provides ASCII, DF1, DH-485, and Modbus communication options. Optional nonvolatile memory expansion uses the 1784-CF128 CompactFlash card. The processor draws 1.2 A at 5.1V DC and 14 mA at 24V DC backplane power.

TECHNICAL DATA

Technical Specifications

ParameterSpecification
CategoryPLCs
GTIN10612598300713
Weight1.31 lbs (0.60 kg)
Fixed Memory2, 4, or 8 MB
Module TypeProcessor Module
Nonvolatile MemoryCompact Flash Card 1784-CF128
Maximum I-O128,000
CommunicationRS-232 serial port
RS232 ProtocolsASCII DF1 full/half-duplex DF1 radio modem DH-485 Modbus via logic
Maximum Analog I-O4,000
Program Scan Time0.08 milliseconds
User Memory4MB
Backplane Current (5Volts DC)1.2 Amps
Backplane Current (24 Volts DC)14 milliamps
UPC10612598300713
Vibration10-500 Hertz
Relative Humidity5-95 percent
Battery1756-BA1, 1756-BATM or 1756-BATA
Full SupportProgramming Languages
TECHNICAL INFORMATION

Features

  • Integrated 4 MB user memory with 478 KB dedicated I/O memory.
  • Built-in RS-232 serial port supporting ASCII, DF1, DH-485, and Modbus via logic.
  • Support for up to 250 simultaneous controller connections across network modules.
  • Execution of up to 32 tasks with 100 programs per task.
  • Optional nonvolatile memory storage expansion with 1784-CF128 CompactFlash card.
  • Full architectural support for controller redundancy configurations.
TECHNICAL INFORMATION

Applications

  • Process and factory automation systems requiring medium to large control architectures.
  • Distributed I/O applications using EtherNet/IP and ControlNet networks.
  • High-availability control systems requiring controller redundancy.
TECHNICAL INFORMATION

Connections / Interfaces

  • Onboard RS-232 serial interface port.
  • ControlNet connections via 1756-CN2/A, 1756-CN2/B, 1756-CNB/D, or 1756-CNB/E modules.
  • EtherNet/IP network connections via 1756-EN2x and 1756-ENBT communication modules.
  • Data Highway Plus, DeviceNet, SynchLink, and Remote I/O network interface support.
TECHNICAL INFORMATION

Installation Guidelines

  1. Mount module into slot locations within compatible 1756-A4, 1756-A7, 1756-A10, 1756-A13, or 1756-A17 chassis.
  2. Maintain ambient operating temperatures between 0 and 60 degrees Celsius.
  3. Ensure noncondensing operating relative humidity remains between 5% and 95%.
TECHNICAL INFORMATION

Configuration Guidelines

  1. Configure controller properties and download application logic using compatible RSLinx and programming software.
  2. Configure RS-232 port driver settings for DF1, DH-485, ASCII, or Modbus communication.
  3. Install the optional 1784-CF128 CompactFlash card for nonvolatile program storage backup.
TECHNICAL INFORMATION

Compatibility

  • Compatible with ControlLogix chassis models 1756-A4, 1756-A7, 1756-A10, 1756-A13, and 1756-A17.
  • Series A and Series B versions are compatible with RSLinx software.
  • Supported by battery part numbers 1756-BA1, 1756-BATM, and 1756-BATA.
TECHNICAL INFORMATION

Lifecycle / Replacement Information

  • The 1756-L62 controller entered discontinued lifecycle status on June 01, 2017.
  • The designated functional replacement model is the 1756-L72 processor.
COMPATIBILITY

Compatibility & Replacement

COMPATIBLE MODELSCompatible with ControlLogix chassis models 1756-A4, 1756-A7, 1756-A10, 1756-A13, and 1756-A17. Series A and Series B versions are compatible with RSLinx software. Supported by battery part numbers 1756-BA1, 1756-BATM, and 1756-BATA.

Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.

PART VERIFICATION

Before You Order

Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.

01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS

From RFQ to Dispatch

1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ

Frequently Asked Questions

What is the memory capacity of the Allen-Bradley 1756-L62 controller?
The 1756-L62 includes 4 MB of integrated user memory and 478 KB of dedicated I/O memory.
What is the functional replacement for the discontinued 1756-L62?
The official functional replacement model for the discontinued 1756-L62 is the ControlLogix 1756-L72 processor module.
Which chassis models support the 1756-L62 processor?
The 1756-L62 is compatible with Allen-Bradley 1756-A4, 1756-A7, 1756-A10, 1756-A13, and 1756-A17 chassis models.
What protocols does the 1756-L62 serial port support?
The RS-232 port supports ASCII, DF1 full/half-duplex, DF1 radio modem, DH-485, and Modbus via logic.
Condition Confirmed Before OrderQuoted condition is confirmed before payment and dispatch.
Warranty & Returns12 Months standard warranty and 30-day return request period.International DeliveryShipping method is selected according to destination and shipment size.
Technical Source PolicySpecifications are published only when supported by product or manufacturer references.
NEED THIS PART?

1756-L62

Send the quantity and destination country. We will confirm stock, condition, price and lead time.

Get Product Updates and Stock Availability Alerts

    REQUEST A QUOTE

    Check Price & Availability

    ProductAllen-Bradley 1756-L62 ControlLogix Processor Module
    Part Number: 1756-L62

      Request a Quote

      Send us the required quantity and destination. We will reply with current availability, lead time and final pricing.

      Home
      Products
      Account