HomeAllen-BradleyControlLogixControllerAllen-Bradley 1756-L75 ControlLogix Controller
Allen-Bradley•Controller

Allen-Bradley 1756-L75 ControlLogix Controller

Pricing
Request Pricing
Contact us for current price and availability.

The Allen-Bradley 1756-L75 is a ControlLogix controller designed for industrial automation environments. This unit includes 32 MB of user memory for logic execution. It also provides 0.98 MB of dedicated memory for I/O operations. The controller handles demanding data processing tasks across distributed automation architecture. It supports up to 128,000 digital I/O points and 4,000 analog I/O points.

ManufacturerAllen-Bradley
Part Number1756-L75
Product TypeController
ConditionNew
Warranty12 Months
AvailabilityRequest current stock
12-Month Warranty30-Day Return Request WindowGlobal Shipping Support
✓
12 Months WarrantyCommercial warranty confirmed with quotation.
↩
30-Day Return RequestEligible returns subject to authorization.
✈
Worldwide ShippingCourier and freight options for international orders.
#
Part Number VerificationSend a label photo when suffix or revision is uncertain.
PRODUCT INFORMATION

Product Overview

The Allen-Bradley 1756-L75 is a ControlLogix controller designed for industrial automation environments. This unit includes 32 MB of user memory for logic execution. It also provides 0.98 MB of dedicated memory for I/O operations. The controller handles demanding data processing tasks across distributed automation architecture. It supports up to 128,000 digital I/O points and 4,000 analog I/O points.

Networking and architecture integration are facilitated through an integrated USB port alongside network support. The controller accommodates Ethernet, ControlNet, and DeviceNet communication protocols. It supports up to 500 simultaneous controller connections. Full controller redundancy is supported to maintain high system availability. The operating architecture runs up to 32 simultaneous tasks with 100 programs per task.

TECHNICAL DATA

Technical Specifications

ParameterSpecification
UPC612598876051
Weight1.00 lbs (0.45 kg)
Maximum Number of Tasks32 Tasks
Maximum Programs per Task100 Programs per Task
Event Task OptionsAll event triggers
Built-In USB Port1 USB Port
Ethernet CommunicationSupported
Maximum Number of Controller Connections500 Connections
ControlNet Communication OptionsSupported
Controller Redundancy OptionFull Support
DeviceNet CommunicationSupported
User Memory32 MB
I/O Memory0.98 MB
Maximum Digital I/O128,000 I/O
Maximum Analog I/O4000 I/O
TECHNICAL INFORMATION

Features

  • Features 32 MB of user data memory and 0.98 MB of dedicated I/O memory.
  • Supports up to 32 concurrent tasks with 100 programs allowed per task.
  • Provides execution compatibility across all event triggers for event tasks.
  • Maintains up to 500 simultaneous communication connections across automation networks.
  • Includes an onboard USB port for direct controller programming and diagnostics.
  • Offers complete controller redundancy capability for critical operations.
  • Scales up to 128,000 digital I/O points and 4,000 analog I/O points.
TECHNICAL INFORMATION

Applications

  • High-capacity industrial manufacturing systems requiring extensive digital and analog I/O control.
  • Critical process facilities that implement dual-controller redundancy to prevent downtime.
  • Plant-wide automation systems integrating Ethernet, ControlNet, and DeviceNet communication architectures.
TECHNICAL INFORMATION

Connections / Interfaces

  • One built-in USB port for local programming, firmware maintenance, and diagnostics.
  • Supports connection to Ethernet, ControlNet, and DeviceNet communication modules.
  • Maintains up to 500 simultaneous controller communication connections.
TECHNICAL INFORMATION

Installation Guidelines

  1. Mount the module into any available slot of a 1756 ControlLogix chassis.
  2. Ensure enclosure cooling maintains ambient temperatures within operating specifications.
  3. Ground the ControlLogix chassis properly before operating the system.
TECHNICAL INFORMATION

Configuration Guidelines

  1. Allocate user program routines within the 32 MB user memory allocation.
  2. Configure controller tasks up to the maximum limit of 32 concurrent tasks.
  3. Assign up to 100 programs per task based on application sequencing needs.
  4. Enable controller redundancy features when using dual-controller high-availability architecture.
TECHNICAL INFORMATION

Compatibility

  • Compatible with Allen-Bradley ControlLogix 1756 chassis backplanes.
  • Integrates with ControlLogix communication interface modules for Ethernet, ControlNet, and DeviceNet.
COMPATIBILITY

Compatibility & Replacement

COMPATIBLE MODELSCompatible with Allen-Bradley ControlLogix 1756 chassis backplanes. Integrates with ControlLogix communication interface modules for Ethernet, ControlNet, and DeviceNet.

Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.

PART VERIFICATION

Before You Order

Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.

01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS

From RFQ to Dispatch

1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ

Frequently Asked Questions

How much user memory is available on the Allen-Bradley 1756-L75?
The 1756-L75 provides 32 MB of user memory along with 0.98 MB of dedicated I/O memory.
Does the 1756-L75 controller support redundancy?
Yes. The 1756-L75 provides full support for controller redundancy in high-availability applications.
How many tasks and programs can the 1756-L75 execute?
The controller executes up to 32 tasks concurrently, with up to 100 programs allowed per task.
What communication interfaces are supported by the 1756-L75?
The unit features a built-in USB port and supports Ethernet, ControlNet, and DeviceNet networks via communication modules.
Condition Confirmed Before OrderQuoted condition is confirmed before payment and dispatch.
Warranty & Returns12 Months standard warranty and 30-day return request period.International DeliveryShipping method is selected according to destination and shipment size.
Technical Source PolicySpecifications are published only when supported by product or manufacturer references.
NEED THIS PART?

1756-L75

Send the quantity and destination country. We will confirm stock, condition, price and lead time.

Get Product Updates and Stock Availability Alerts

    REQUEST A QUOTE

    Check Price & Availability

    ProductAllen-Bradley 1756-L75 ControlLogix Controller
    Part Number: 1756-L75

      Request a Quote

      Send us the required quantity and destination. We will reply with current availability, lead time and final pricing.

      Home
      Products
      Account