HomeAllen-BradleyPLC-5Analog Input ModuleAllen-Bradley 1771-NT2 PLC-5 Analog Input Module
Allen-Bradley•Analog Input Module

Allen-Bradley 1771-NT2 PLC-5 Analog Input Module

Pricing
Request Pricing
Contact us for current price and availability.

The Allen-Bradley 1771-NT2 is a PLC-5 high-resolution isolated analog input module. This unit provides 16-bit resolution with 0.01% typical accuracy over Full Scale Range. The hardware accommodates eight isolated input channels for thermocouple and millivolt signals. It features an input bandwidth of 9 Hz and an update time of 25 milliseconds. The underrange threshold is -5.5 mV and the overrange threshold is +56.0 mV.

ManufacturerAllen-Bradley
Part Number1771-NT2
Product TypeAnalog Input Module
ConditionNew
Warranty12 Months
AvailabilityRequest current stock
12-Month Warranty30-Day Return Request WindowGlobal Shipping Support
✓
12 Months WarrantyCommercial warranty confirmed with quotation.
↩
30-Day Return RequestEligible returns subject to authorization.
✈
Worldwide ShippingCourier and freight options for international orders.
#
Part Number VerificationSend a label photo when suffix or revision is uncertain.
PRODUCT INFORMATION

Product Overview

The Allen-Bradley 1771-NT2 is a PLC-5 high-resolution isolated analog input module. This unit provides 16-bit resolution with 0.01% typical accuracy over Full Scale Range. The hardware accommodates eight isolated input channels for thermocouple and millivolt signals. It features an input bandwidth of 9 Hz and an update time of 25 milliseconds. The underrange threshold is -5.5 mV and the overrange threshold is +56.0 mV.

The 1771-NT2 module mounts into standard 1771 series I/O chassis assemblies. Normal mode noise rejection is 50 dB at 50 Hz and 60 dB at 60 Hz. Common mode noise rejection is 150 dB at 60 Hz. Operating temperatures range from 0 to 60 degrees Celsius in Pollution Degree 2 environments. Field connections interface with the module through the 1771-WH arm or 1771-RTP1 interface.

TECHNICAL DATA

Technical Specifications

ParameterSpecification
CategoryPLCs
Product LinePLC 5
UPC612598123339
Weight1.75 lbs (0.79 kg)
Module TypeN-Series Analog I/O Module
Number of Inputs8 Inputs
Input TypesTC/Milivolt
Input Resolution-5/+55 Milivolts (0.95 Microvolt/bit); B, R, S, Thermocouple (0.03 Celsius/bit, 0.06 Milivolt/bit); E, J, K, T, Thermocouple (0.1 Celsius/bit, 0.2 Fahrenheit/bit); C Thermocouple (0.07 Celsius/bit, 0.1 Fahrenheit/bit); N Thermocouple (0.03 Celsius/bit, 0.
Number of Outputs0 Outputs
RTP Choice1771-RTP1
Backplane Current1.5 Amperes
Data FormatBDC or Natural Binary
Typical AC Signal Delay (Off)45 (+/- 15) ms
Typical DC Signal Delay (Off)50 ms
Wiring Arm1771-WH
MountingRack Mountable
TECHNICAL INFORMATION

Features

  • Eight isolated input channels accept millivolt signals and thermocouples.
  • Conversion resolution reaches 16 bits with 0.01% typical accuracy over full scale.
  • Operating bandwidth reaches 9 Hz with a maximum 25-millisecond update time.
  • Normal mode rejection provides 50 dB at 50 Hz and 60 dB at 60 Hz.
  • Common mode noise rejection provides 150 dB at 60 Hz.
  • Selectable data representation supports BCD or Natural Binary formatting.
  • Open-type construction meets Pollution Degree 2 industrial environment standards.
TECHNICAL INFORMATION

Applications

  • Demanding process control monitoring applications requiring isolated analog inputs.
  • Low-voltage millivolt instrumentation data acquisition across PLC-5 rack systems.
  • Process temperature measurement using isolated thermocouple field sensors.
TECHNICAL INFORMATION

Connections / Interfaces

  • Field signals terminate directly through the 1771-WH wiring arm.
  • Remote field connections connect through the 1771-RTP1 remote termination panel.
  • Backplane connectors plug directly into standard 1771 I/O chassis slots.
TECHNICAL INFORMATION

Installation Guidelines

  1. Seat the module into any compatible slot of a de-energized 1771 rack.
  2. Maintain an operating industrial atmosphere conforming to Pollution Degree 2 requirements.
  3. Ensure the enclosure is accessible only by means of a tool or appliance.
  4. Fasten the 1771-WH wiring arm securely before applying electrical power.
TECHNICAL INFORMATION

Configuration Guidelines

  1. Configure channel ranges and operating parameters using IOCONFIG software.
  2. Select Natural Binary or BCD data format for PLC-5 processor communications.
  3. Configure each channel independently according to application requirements.
  4. Define programmable reset values for outputs based on system requirements.
TECHNICAL INFORMATION

Compatibility

  • Allen-Bradley PLC-5 1771 I/O chassis racks.
  • Allen-Bradley 1771-WH field wiring arm assemblies.
  • Allen-Bradley 1771-RTP1 remote termination panel hardware.
TECHNICAL INFORMATION

Compliance and Certifications

  • EN/IEC 60664-1 Pollution Degree 2 industrial environment standard
TECHNICAL RESOURCES

Documentation

COMPATIBILITY

Compatibility & Replacement

COMPATIBLE MODELSAllen-Bradley PLC-5 1771 I/O chassis racks. Allen-Bradley 1771-WH field wiring arm assemblies. Allen-Bradley 1771-RTP1 remote termination panel hardware.

Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.

PART VERIFICATION

Before You Order

Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.

01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS

From RFQ to Dispatch

1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ

Frequently Asked Questions

What sensor inputs does the 1771-NT2 module support?
The module supports -5 to +55 mV inputs and B, C, E, J, K, N, R, and S thermocouples.
Which wiring arm is compatible with the 1771-NT2?
The module connects using the 1771-WH wiring arm or the 1771-RTP1 remote termination panel.
How many input channels does the 1771-NT2 provide?
The 1771-NT2 provides eight isolated, independently configurable input channels.
What software utility is used to configure the 1771-NT2?
The IOCONFIG software utility is recommended to configure channel parameters on this module.
Condition Confirmed Before OrderQuoted condition is confirmed before payment and dispatch.
Warranty & Returns12 Months standard warranty and 30-day return request period.International DeliveryShipping method is selected according to destination and shipment size.
Technical Source PolicySpecifications are published only when supported by product or manufacturer references.
NEED THIS PART?

1771-NT2

Send the quantity and destination country. We will confirm stock, condition, price and lead time.

Get Product Updates and Stock Availability Alerts

    REQUEST A QUOTE

    Check Price & Availability

    ProductAllen-Bradley 1771-NT2 PLC-5 Analog Input Module
    Part Number: 1771-NT2

      Request a Quote

      Send us the required quantity and destination. We will reply with current availability, lead time and final pricing.

      Home
      Products
      Account