PRODUCT INFORMATION
Product Overview
The Allen-Bradley 2711-B6C9L1 is a PanelView 600 Color/Touch/Keypad operator terminal within the PanelView series. This unit features a 5-inch color display for monitoring machine functions. Operators enter process values and system commands using both keypad keys and touch cells. The terminal operates on a direct current supply ranging from 18 to 32 VDC.
The terminal includes 240 KB of internal memory for user application storage. Communication occurs through an RS-232 port supporting the DH-485 protocol. A secondary RS-232 port provides connection to an external serial printer. PanelBuilder32 software configures terminal graphics, data tags, and operator screens. Firmware versions for this terminal range from 1.00 to 4.48 across series A through L.
TECHNICAL DATA
Technical Specifications
| Parameter | Specification |
|---|
| Category | Panelviews |
|---|
| Product Line | Panelview 600 |
|---|
| Weight | 4.44 lbs (2.01 kg) |
|---|
| Display Size | 5 in. |
|---|
| Display Color | Color |
|---|
| Input Type | Keypad/Touchscreen |
|---|
| Communication | RS-232 (DH-485) and RS-232 Printer |
|---|
| Input Power | 18-32 VDC |
|---|
| Memory | 240 KB |
|---|
| Backlight | 2711-NL5 |
|---|
| Communication Cable | 2711-NC14 |
|---|
| Product Lifecycle Status* | Discontinued/Obsolete |
|---|
TECHNICAL INFORMATION
Features
- Equipped with a 5-inch color display.
- Combines dual input methods using numeric keypad buttons and touchscreen cells.
- Operates from an 18 to 32 VDC input power supply.
- Contains 240 KB of internal memory for application storage.
- Provides RS-232 communication with DH-485 protocol support.
- Includes a dedicated RS-232 serial printer interface.
- Uses a field-replaceable 2711-NL5 internal backlight lamp.
TECHNICAL INFORMATION
Applications
- Machinery status monitoring and parameter entry.
- Point-to-point communication with SLC 500 and MicroLogix programmable controllers.
- Industrial operator interface stations in DH-485 automation networks.
TECHNICAL INFORMATION
Connections / Interfaces
- The primary RS-232 port communicates using the DH-485 protocol.
- The secondary RS-232 port provides a connection for an external printer.
- Compatible controller communication uses the 2711-NC14 cable.
- Connection to a DH-485 network can use an AIC+ module.
TECHNICAL INFORMATION
Installation Guidelines
- Verify that input power provides between 18 and 32 VDC prior to connection.
- Mount the terminal securely in an industrial enclosure cutout.
- Allow adequate clearance around the terminal enclosure for proper ventilation.
TECHNICAL INFORMATION
Configuration Guidelines
- Configure application screens and data tags using PanelBuilder32 software.
- Set the DH-485 node address and baud rate to match controller network settings.
TECHNICAL INFORMATION
Compatibility
- Connects to Allen-Bradley SLC 500 and MicroLogix controllers via DH-485 protocol.
- Connects to a DH-485 network using an AIC+ module.
- Uses the 2711-NL5 replacement backlight lamp.
TECHNICAL INFORMATION
Lifecycle / Replacement Information
- The 2711-B6C9L1 terminal is discontinued and classified as obsolete by the manufacturer.
- Field maintenance utilizes replacement parts such as the 2711-NL5 backlight.
TECHNICAL RESOURCES
Documentation
COMPATIBILITY
Compatibility & Replacement
COMPATIBLE MODELSConnects to Allen-Bradley SLC 500 and MicroLogix controllers via DH-485 protocol. Connects to a DH-485 network using an AIC+ module. Uses the 2711-NL5 replacement backlight lamp.
Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.
PART VERIFICATION
Before You Order
Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.
01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS
From RFQ to Dispatch
1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ
Frequently Asked Questions
What power input is required for the 2711-B6C9L1?
The terminal requires a direct current power supply operating between 18 and 32 VDC.
Which communication ports and protocols are supported on the 2711-B6C9L1?
The terminal provides an RS-232 DH-485 communication port and an RS-232 printer port.
What replacement backlight is compatible with the 2711-B6C9L1?
The internal replacement backlight part number is 2711-NL5.
What is the indicative market reference price for the 2711-B6C9L1?
Observed market reference pricing is approximately $1,980.00 USD. This figure is indicative market reference pricing only and is not a final quotation.