The General Electric 269PLUS-10C-HI is a Multilin series motor management relay designed for medium AC motors. This high voltage model operates across a control power range of 90 to 300 VDC or 80 to 265 VAC. The control power circuit supports operating line frequencies of 50 Hz and 60 Hz. It integrates a 10C input sensor type designed specifically for 10 Ohm copper RTD devices. One relay is required for each protected motor to ensure standard mon

ManufacturerGeneral Electric
Part Number269PLUS-10C-HI
Product TypeMotor Management Relay
ConditionNew
Warranty12 Months
AvailabilityRequest current stock
12-Month Warranty30-Day Return Request WindowGlobal Shipping Support
✓
12 Months WarrantyCommercial warranty confirmed with quotation.
↩
30-Day Return RequestEligible returns subject to authorization.
✈
Worldwide ShippingCourier and freight options for international orders.
#
Part Number VerificationSend a label photo when suffix or revision is uncertain.
PRODUCT INFORMATION

Product Overview

The General Electric 269PLUS-10C-HI is a Multilin series motor management relay designed for medium AC motors. This high voltage model operates across a control power range of 90 to 300 VDC or 80 to 265 VAC. The control power circuit supports operating line frequencies of 50 Hz and 60 Hz. It integrates a 10C input sensor type designed specifically for 10 Ohm copper RTD devices. One relay is required for each protected motor to ensure standard monitoring coverage.

The relay acts as a pilot device and does not carry primary motor currents directly. It monitors phase and ground fault currents through external current transformers. Trip commands trigger external contactors or circuit breakers whenever fault conditions are detected. The unit records pre-trip electrical measurements, relay setpoints, and motor statistical logs in non-volatile memory. It automatically calculates learned values such as acceleration time, cool-down rates, and inrush currents.

TECHNICAL DATA

Technical Specifications

ParameterSpecification
Manufacturer LocationMarkham, Ontario, Canada
SoftwareEnerVista 269
User Manual1601-0013-E4
Dimensionsapprox. 289mm H, 192 mm L, 121 mm W
Weight5lb, 14oz
Altitude Rating2000m
Control Power Frequency50/60 Hz
Running Hours Counter Accuracy±1%
TECHNICAL INFORMATION

Features

  • Accepts 10 Ohm copper RTD inputs through the integrated 10C sensor interface.
  • Operates with control power supplies of 90 to 300 VDC or 80 to 265 VAC at 50/60 Hz.
  • Functions as a pilot device using current transformers without conducting primary line current.
  • Stores motor statistics, relay setpoints, and pre-trip fault data in non-volatile memory.
  • Calculates learned operating parameters including acceleration time, cool-down rates, and inrush currents.
  • Maintains running hours counter accuracy within plus or minus 1 percent.
TECHNICAL INFORMATION

Applications

  • Protection and monitoring for medium AC induction motors.
  • Thermal monitoring of motor windings using 10 Ohm copper RTDs.
  • Switchgear and motor control center pilot breaker actuation.
TECHNICAL INFORMATION

Connections / Interfaces

  • Interfaces with phase and ground current transformers for line current monitoring.
  • Connects to 10 Ohm copper RTD inputs for motor thermal feedback.
TECHNICAL INFORMATION

Installation Guidelines

  1. Install one unit per motor across medium AC motor installations.
  2. Verify control power supply matches 90 to 300 VDC or 80 to 265 VAC.
  3. Route current transformer secondary wiring to relay terminals rather than direct primary current.
  4. Maintain operating elevations below the 2000 meter altitude rating.
TECHNICAL INFORMATION

Configuration Guidelines

  1. Configure protection settings using EnerVista 269 software.
  2. Consult GE Multilin 269 Plus instruction manual 1601-0013-D3 or 1601-0013-E4 for setpoint tables.
  3. Permit the unit to establish baseline learned motor parameters during initial motor start cycles.
TECHNICAL INFORMATION

Compatibility

  • Compatible with medium AC motors requiring discrete pilot protection.
  • Compatible with 10 Ohm copper resistance temperature detectors.
COMPATIBILITY

Compatibility & Replacement

COMPATIBLE MODELSCompatible with medium AC motors requiring discrete pilot protection. Compatible with 10 Ohm copper resistance temperature detectors.

Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.

PART VERIFICATION

Before You Order

Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.

01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS

From RFQ to Dispatch

1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ

Frequently Asked Questions

What motor types are compatible with the General Electric 269PLUS-10C-HI?
The unit protects medium AC motors. Each individual motor requires one dedicated relay.
What RTD sensor type is supported by the 269PLUS-10C-HI?
The 10C designation specifies compatibility with 10 Ohm copper RTD temperature sensors.
Does this relay carry primary motor load currents?
No, it acts as a pilot device. It monitors current through current transformers and trips external breakers.
What software is used to configure the 269PLUS-10C-HI relay?
The unit is configured and monitored using EnerVista 269 software.
Condition Confirmed Before OrderQuoted condition is confirmed before payment and dispatch.
Warranty & Returns12 Months standard warranty and 30-day return request period.International DeliveryShipping method is selected according to destination and shipment size.
Technical Source PolicySpecifications are published only when supported by product or manufacturer references.
NEED THIS PART?

269PLUS-10C-HI

Send the quantity and destination country. We will confirm stock, condition, price and lead time.

Get Product Updates and Stock Availability Alerts

    REQUEST A QUOTE

    Check Price & Availability

    ProductGeneral Electric 269PLUS-10C-HI Multilin Motor Management Relay
    Part Number: 269PLUS-10C-HI

      Request a Quote

      Send us the required quantity and destination. We will reply with current availability, lead time and final pricing.

      Home
      Products
      Account