PRODUCT INFORMATION
Product Overview
The General Electric IC200MDL750 is a 32-point discrete output module for the VersaMax I/O platform. This unit features thirty-two positive logic digital output channels organized into two isolated groups of sixteen. The module delivers a nominal output voltage of 12 or 24 VDC across a 10.2 to 30 VDC range. Each output channel supplies up to 0.5 amperes of continuous load current for field actuators.
The module interfaces directly with standard VersaMax carrier bases installed on standard 35 mm DIN rails. Field devices connect through the carrier terminals without requiring extra sub-panel terminal strips. Individual LED indicators display the active logic status of each channel alongside OK and field power indicators. Current consumption from the VersaMax backplane supply is rated at 90 milliamperes maximum.
TECHNICAL DATA
Technical Specifications
| Parameter | Specification |
|---|
| Backplane Current | 90 milliamperes |
|---|
| Current Draw | 90 mA, maximum |
|---|
| Current per Point | 0.5 Amperes |
|---|
| Environment | Class I Division 2 |
|---|
| External Power supply | 10.2-30 VDC, 12/24 VDC nominal |
|---|
| Inrush current | 2.0 A inrush maximum for 100 ms |
|---|
| Inrush current, max | 2 Amperes |
|---|
| Internal fuses | None |
|---|
| Isolation | 250VAC continuous; 1500VAC for 1 minute |
|---|
| LED indicators | Individual channel LED indicators; OK LED; FLD PWR LED |
|---|
| Load Current per Point | 0.5 A per point |
|---|
| Mounting | DIN Rail |
|---|
| No of Channels | 32 |
|---|
| No. of channel per group | Sixteen (16) |
|---|
| No. of input groups | Two (2) |
|---|
| Output Voltage Range | +10.2 to +30VDC |
|---|
| Output current per channel, min. | 0.5 Amperes |
|---|
| Output signal, nominal | 12/24 VDC |
|---|
| Output signal, range | 10.2-30 VDC |
|---|
| Output voltage, nominal | 12 / 24VDC |
|---|
| Points | 32 |
|---|
| Product Description | Discrete Output Module |
|---|
| Product Line | Versamax |
|---|
| Response time, OFF transition | 1.0 ms |
|---|
| Response time, ON transition | 0.2 ms |
|---|
| Temperature | 0-30 degrees Celsius |
|---|
| Weight | 0.69 lbs (0.31 kg) |
|---|
TECHNICAL INFORMATION
Features
- Provides 32 discrete output points arranged into two groups of 16 channels.
- Supports a nominal operating voltage of 12/24 VDC with a 10.2 to 30 VDC range.
- Delivers 0.5 amperes rated current per point for dual-state field loads.
- Includes individual status LEDs for channel activity alongside OK and field power indicators.
- Operates with high-speed switching response times of 0.2 ms on and 1.0 ms off.
TECHNICAL INFORMATION
Applications
- Actuation of dual-state industrial solenoid valves.
- Energizing 24 VDC intermediate control relays and contactor coils.
- Driving binary pilot lamps and panel annunciator indicators.
- Distributed switching inside Class I Division 2 hazardous locations.
TECHNICAL INFORMATION
Connections / Interfaces
- Requires a VersaMax carrier base to host all field wiring terminals.
- Provides dedicated DC+ and DC- power connections for each channel group.
- Connects to the VersaMax backplane via the base carrier receptacle.
TECHNICAL INFORMATION
Installation Guidelines
- Mount the supporting carrier base on a standard 35 mm DIN rail.
- Supports horizontal or vertical orientation inside the industrial enclosure.
- Install external suppression circuits across inductive loads connected to field outputs.
- Maintain ambient operating temperatures between 0 and 30 degrees Celsius to prevent derating.
TECHNICAL INFORMATION
Compatibility
- Compatible with General Electric VersaMax carrier bases and distributed I/O network interface units.
TECHNICAL INFORMATION
Compliance and Certifications
- Class I Division 2 hazardous location certified
COMPATIBILITY
Compatibility & Replacement
COMPATIBLE MODELSCompatible with General Electric VersaMax carrier bases and distributed I/O network interface units.
Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.
PART VERIFICATION
Before You Order
Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.
01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS
From RFQ to Dispatch
1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ
Frequently Asked Questions
What is the rated load current for the IC200MDL750?
Each output point delivers up to 0.5 amperes of continuous load current.
Does the IC200MDL750 require an external carrier base?
Yes. The module snaps into a VersaMax carrier base that hosts all field wiring terminals.
Are inductive suppression circuits required with this module?
Yes. Users must wire external suppression devices across inductive loads such as relay coils or solenoids.
What is the reference price for the IC200MDL750?
Pricing depends on market availability and condition. Figures provided represent indicative market reference pricing only and are not a final quotation.