The General Electric SR489-CASE is a companion case designed for the Multilin 489 generator management relay. This enclosure features a full drawout mechanism with automatic CT shorting capability. A dust-tight door protects internal electrical components from contamination. The case design also includes an integrated seal provision for tamper protection. The IP rating for this unit is classified as IP10A.

ManufacturerGeneral Electric
Part NumberSR489-CASE
Product TypeCase for 489 Generator Management Relay
ConditionNew
Warranty12 Months
AvailabilityRequest current stock
12-Month Warranty30-Day Return Request WindowGlobal Shipping Support
✓
12 Months WarrantyCommercial warranty confirmed with quotation.
↩
30-Day Return RequestEligible returns subject to authorization.
✈
Worldwide ShippingCourier and freight options for international orders.
#
Part Number VerificationSend a label photo when suffix or revision is uncertain.
PRODUCT INFORMATION

Product Overview

The General Electric SR489-CASE is a companion case designed for the Multilin 489 generator management relay. This enclosure features a full drawout mechanism with automatic CT shorting capability. A dust-tight door protects internal electrical components from contamination. The case design also includes an integrated seal provision for tamper protection. The IP rating for this unit is classified as IP10A.

The assembly supports mounting into a standard 19-inch rack or directly onto an enclosure panel. During installation, operators bend retaining tabs horizontally to hold the bezel snugly against the panel front. Sufficient clearance must be provided so the front door swings open without interference. After mechanical mounting is complete, the case is prepared for panel termination and wiring.

TECHNICAL DATA

Technical Specifications

ParameterSpecification
Door TypeDust Tight Door
Drawout TypeFully Drawout for Automatic CT Shorts
IP ClassIP10A
Mounting Configuration19" Rack Mount or Panel
Operating Temperature Range-40 to 60 °C
SealSeal Provision
TECHNICAL INFORMATION

Features

  • Features a full drawout design with automatic CT shorting.
  • Includes a protective dust-tight front door.
  • Provides integrated sealing provisions for panel security.
  • Supports standard 19-inch rack mounting and panel mounting.
  • Rated for operating temperatures between -40 and 60 °C.
  • Delivers an IP10A ingress protection rating.
TECHNICAL INFORMATION

Applications

  • Housing Multilin 489 generator management relays in switchgear cabinets.
  • Mounting protection instrumentation in 19-inch control racks.
  • Panel installations requiring CT shorting drawout functionality.
TECHNICAL INFORMATION

Installation Guidelines

  1. Verify sufficient clearance exists for the front door to swing open fully.
  2. Apply firm pressure on the front to fit the bezel snugly against the panel.
  3. Bend out the pair of retaining tabs horizontally from each case side.
  4. Proceed with panel termination and field wiring once mechanical mounting is secure.
TECHNICAL INFORMATION

Compatibility

  • Engineered specifically as the companion enclosure for General Electric Multilin 489 generator management relays.
COMPATIBILITY

Compatibility & Replacement

COMPATIBLE MODELSEngineered specifically as the companion enclosure for General Electric Multilin 489 generator management relays.

Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.

PART VERIFICATION

Before You Order

Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.

01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS

From RFQ to Dispatch

1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ

Frequently Asked Questions

What mounting configurations are supported by the SR489-CASE?
The unit supports 19-inch rack mounting as well as direct panel mounting.
How does the SR489-CASE protect current transformer circuits during maintenance?
The enclosure incorporates a full drawout mechanism that automatically shorts CT circuits upon withdrawal.
What is the ingress protection rating of the General Electric SR489-CASE?
The enclosure provides an IP10A ingress rating and features a dust-tight door.
Condition Confirmed Before OrderQuoted condition is confirmed before payment and dispatch.
Warranty & Returns12 Months standard warranty and 30-day return request period.International DeliveryShipping method is selected according to destination and shipment size.
Technical Source PolicySpecifications are published only when supported by product or manufacturer references.
NEED THIS PART?

SR489-CASE

Send the quantity and destination country. We will confirm stock, condition, price and lead time.

Get Product Updates and Stock Availability Alerts

    REQUEST A QUOTE

    Check Price & Availability

    ProductGeneral Electric SR489-CASE Multilin Case for 489 Generator Management Relay
    Part Number: SR489-CASE

      Request a Quote

      Send us the required quantity and destination. We will reply with current availability, lead time and final pricing.

      Home
      Products
      Account