The General Electric IC694ALG223 is an Analog current input module designed for PACSystems RX3i control systems. This high-density module provides sixteen single-ended analog input channels for industrial process acquisition. It converts incoming analog current signals into 12-bit digital values. Supported signal ranges include 0 to 20 mA, standard 4 to 20 mA, and enhanced 4 to 20 mA. The module occupies a single slot in any compatible RX3i backp

ManufacturerGeneral Electric
Part NumberIC694ALG223
Product TypeAnalog current input module
ConditionNew
Warranty12 Months
Lifecycle StatusProduct lifecycle status is currently verified as Active.
AvailabilityRequest current stock
12-Month Warranty30-Day Return Request WindowGlobal Shipping Support
✓
12 Months WarrantyCommercial warranty confirmed with quotation.
↩
30-Day Return RequestEligible returns subject to authorization.
✈
Worldwide ShippingCourier and freight options for international orders.
#
Part Number VerificationSend a label photo when suffix or revision is uncertain.
PRODUCT INFORMATION

Product Overview

The General Electric IC694ALG223 is an Analog current input module designed for PACSystems RX3i control systems. This high-density module provides sixteen single-ended analog input channels for industrial process acquisition. It converts incoming analog current signals into 12-bit digital values. Supported signal ranges include 0 to 20 mA, standard 4 to 20 mA, and enhanced 4 to 20 mA. The module occupies a single slot in any compatible RX3i backplane rack.

The module interfaces directly with field transmitters, transducers, and signal isolators. It draws 120 mA from the backplane 5 VDC bus. An external 24 VDC supply provides 65 mA for field loop currents. The hardware reports external power supply operational status directly to the CPU. When configured for enhanced 4 to 20 mA mode, the unit provides open-wire fault detection.

TECHNICAL DATA

Technical Specifications

ParameterSpecification
Weight1.31 lbs (0.60 kg)
Product DescriptionAnalog input module
No of ChannelsSixteen (16) single-ended inputs;
Input Channels16
Nominal Input signal0-20 mA; 4-20 mA (normal); 4-20 mA (enhanced)
Input Current Ranges0 to 20 milliamps, 4 to 20 milliamps
Channel update rate13 ms
Power Requirements120 milliamps at 5 Volts DC
Digital Resolution12 bit
Input Impedance250 ohms
Analog resolution4–20 mA: 4 µA (4 µA/bit) 0–20 mA: 5 µA (5 µA/bit) 4–20 mA Enhanced: 5 µA (5 µA/bit)
External Supply Range20 to 30 Volts DC
Accuracy+/-0.25% of full scale @ 25degrees C (77degrees F); +/- 0.5% of full scale over specified operating temperature range
Input Low Pass Filter Response19 Hz
Current draw120 mA @ 5 VDC; 65 mA @ 24 VDC (user supplied)
Operating Temperature0 to 60 degrees Celsius
Calibration4 µA per count on 4 to 20 mA range; 5 µA per count on 0 to 20 mA and 4 to 20 mA Enhanced
Product Lifecycle StatusActive
TECHNICAL INFORMATION

Features

  • Sixteen single-ended analog current input channels in a single-slot module form factor.
  • Software-configurable ranges for 0 to 20 mA, 4 to 20 mA normal, and 4 to 20 mA enhanced.
  • Internal 12-bit analog-to-digital converter assigned per input channel.
  • Factory calibrated resolution of 4 µA per count for standard 4 to 20 mA operation.
  • Factory calibrated resolution of 5 µA per count for 0 to 20 mA and enhanced ranges.
  • Open-wire fault detection when operating in the 4 to 20 mA enhanced input range.
  • User-configurable high and low process alarm thresholds set through programming software.
  • External power supply status monitoring mapped directly to controller reference memory.
TECHNICAL INFORMATION

Applications

  • Current loop interface for process transmitters measuring pressure, flow, and temperature.
  • Signal acquisition from industrial transducers and instrumentation isolators.
  • Centralized and distributed analog data monitoring in PACSystems RX3i automated architectures.
  • Process monitoring requiring broken-wire diagnostics on 4 to 20 mA control loops.
TECHNICAL INFORMATION

Connections / Interfaces

  • Sixteen single-ended analog input terminals share a common connection.
  • Backplane connection draws 120 mA at 5 VDC through the RX3i chassis connector.
  • External power terminal connection accepts 20 to 30 VDC for input loop power.
TECHNICAL INFORMATION

Installation Guidelines

  1. Insert the module into a single vacant slot of an RX3i chassis or compatible baseplate.
  2. Ensure external 24 VDC power is disconnected before wiring input terminal points.
  3. Use shielded twisted-pair cabling for all low-level analog input current loops.
  4. Maintain module operating environment within the rated 0 to 60 degrees Celsius range.
TECHNICAL INFORMATION

Configuration Guidelines

  1. Configure individual channel ranges as 0-20 mA, 4-20 mA, or 4-20 mA enhanced via software.
  2. Set high and low alarm limits for each active analog channel using control software.
  3. Assign CPU reference memory addresses to read module status and power supply diagnostics.
  4. Select the enhanced 4-20 mA range to enable automatic open-wire detection.
TECHNICAL INFORMATION

Compatibility

  • Installs directly into PACSystems RX3i chassis backplane slots.
  • Operates in local and distributed I/O racks with RX3i and RX7i controllers.
  • Installs into Series 90-30 PLC systems equipped with a serial connector backplane.
TECHNICAL INFORMATION

Lifecycle / Replacement Information

  • Product lifecycle status is currently verified as Active.
COMPATIBILITY

Compatibility & Replacement

COMPATIBLE MODELSInstalls directly into PACSystems RX3i chassis backplane slots. Operates in local and distributed I/O racks with RX3i and RX7i controllers. Installs into Series 90-30 PLC systems equipped with a serial connector backplane.

Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.

PART VERIFICATION

Before You Order

Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.

01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS

From RFQ to Dispatch

1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ

Frequently Asked Questions

What input current ranges are supported by the IC694ALG223?
The module supports 0 to 20 mA, 4 to 20 mA normal, and 4 to 20 mA enhanced ranges.
How does the IC694ALG223 detect open-wire conditions on field loops?
Open-wire detection operates in 4 to 20 mA enhanced mode. It flags input currents falling below 4 mA.
What are the power requirements for operating the IC694ALG223?
It requires 120 mA at 5 VDC from the backplane. It also requires 65 mA from an external 24 VDC supply.
What is the conversion resolution of each channel on the IC694ALG223?
Each channel uses an embedded analog-to-digital converter that provides 12 bits of conversion resolution.
Condition Confirmed Before OrderQuoted condition is confirmed before payment and dispatch.
Warranty & Returns12 Months standard warranty and 30-day return request period.International DeliveryShipping method is selected according to destination and shipment size.
Technical Source PolicySpecifications are published only when supported by product or manufacturer references.
NEED THIS PART?

IC694ALG223

Send the quantity and destination country. We will confirm stock, condition, price and lead time.

Get Product Updates and Stock Availability Alerts

    REQUEST A QUOTE

    Check Price & Availability

    ProductGeneral Electric IC694ALG223 PACSystems RX3i Analog current input module
    Part Number: IC694ALG223

      Request a Quote

      Send us the required quantity and destination. We will reply with current availability, lead time and final pricing.

      Home
      Products
      Account