HomeWoodwardeasYgenGenset Control and Protection UnitWoodward 8440-1857 easYgen Genset Control and Protection Unit
Woodward•Genset Control and Protection Unit

Woodward 8440-1857 easYgen Genset Control and Protection Unit

Pricing
Request Pricing
Contact us for current price and availability.

The Woodward 8440-1857 is an easYgen genset control and protection unit. It operates on a 12/24 Vdc battery power supply. The unit lacks an internal isolated power supply. It draws power directly from a battery and charging alternator setup. This module manages generator set control and electrical protection. The durable plastic housing protects internal circuitry in industrial installations.

ManufacturerWoodward
Part Number8440-1857
Product TypeGenset Control and Protection Unit
ConditionNew
Warranty12 Months
AvailabilityRequest current stock
12-Month Warranty30-Day Return Request WindowGlobal Shipping Support
✓
12 Months WarrantyCommercial warranty confirmed with quotation.
↩
30-Day Return RequestEligible returns subject to authorization.
✈
Worldwide ShippingCourier and freight options for international orders.
#
Part Number VerificationSend a label photo when suffix or revision is uncertain.
PRODUCT INFORMATION

Product Overview

The Woodward 8440-1857 is an easYgen genset control and protection unit. It operates on a 12/24 Vdc battery power supply. The unit lacks an internal isolated power supply. It draws power directly from a battery and charging alternator setup. This module manages generator set control and electrical protection. The durable plastic housing protects internal circuitry in industrial installations.

Electrical connection to the charging alternator utilizes dedicated terminals. Terminal A is labeled as terminal 53. Terminal B is labeled as terminal 52. Battery positive connects to terminal A across an 8 to 40 Vdc range. The auxiliary excitation D+ line connects to terminal B. The unit withstands overvoltage conditions up to 80 Vdc for up to two minutes.

TECHNICAL DATA

Technical Specifications

ParameterSpecification
HousingPlastic
Humidity95%, non condensating
Overvoltage (≤ 2 min)80 Vdc
Power Supply12/24 Vdc
RMS value vibration1.04 Grms
Weightapprox. 800 g
TECHNICAL INFORMATION

Features

  • Operates with 12/24 Vdc systems and battery charging alternators.
  • Includes non-isolated direct power connections for alternator circuits.
  • Withstands temporary overvoltage events up to 80 Vdc for two minutes.
  • Provides dedicated D+ auxiliary excitation input on terminal 52.
  • Housed in a lightweight plastic enclosure weighing approximately 800 grams.
  • Resists mechanical vibration stresses rated up to 1.04 Grms.
  • Tolerates relative humidity levels up to 95 percent non-condensing.
TECHNICAL INFORMATION

Applications

  • Diesel and gas generator set automation and electrical protection.
  • Engine generator monitoring systems requiring battery alternator power.
TECHNICAL INFORMATION

Connections / Interfaces

  • Terminal 53 represents terminal A for battery positive connection.
  • Terminal A accepts direct battery voltage from 8 to 40 Vdc.
  • Terminal 52 represents terminal B for alternator charging circuits.
  • Terminal B interfaces with the D+ auxiliary excitation output.
TECHNICAL INFORMATION

Installation Guidelines

  1. Mount the controller securely within an electrical panel enclosure.
  2. Ensure operating environment does not exceed 95 percent non-condensing humidity.
  3. Verify vibration levels remain within the 1.04 Grms operating specification.
  4. Connect charging alternator excitation lines according to terminal designations.
TECHNICAL INFORMATION

Configuration Guidelines

  1. Configure DC input parameters for 12 Vdc or 24 Vdc system operation.
  2. Confirm battery input voltage stays within the 8 to 40 Vdc operating limits.
PART VERIFICATION

Before You Order

Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.

01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS

From RFQ to Dispatch

1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ

Frequently Asked Questions

What power source does the Woodward 8440-1857 require?
The unit requires a 12/24 Vdc power source from a battery or charging alternator.
Does the 8440-1857 have an isolated internal power supply?
No, the unit has no internal isolated power supply and connects directly to the battery circuit.
Which terminals connect to the charging alternator?
Terminals 52 and 53 connect to the charging alternator circuit.
What is the maximum overvoltage rating for this control unit?
The unit withstands up to 80 Vdc overvoltage for durations of two minutes or less.
Condition Confirmed Before OrderQuoted condition is confirmed before payment and dispatch.
Warranty & Returns12 Months standard warranty and 30-day return request period.International DeliveryShipping method is selected according to destination and shipment size.
Technical Source PolicySpecifications are published only when supported by product or manufacturer references.
NEED THIS PART?

8440-1857

Send the quantity and destination country. We will confirm stock, condition, price and lead time.

Get Product Updates and Stock Availability Alerts

    REQUEST A QUOTE

    Check Price & Availability

    ProductWoodward 8440-1857 easYgen Genset Control and Protection Unit
    Part Number: 8440-1857

      Request a Quote

      Send us the required quantity and destination. We will reply with current availability, lead time and final pricing.

      Home
      Products
      Account