PRODUCT INFORMATION
Product Overview
The Allen-Bradley 1747-DTAM is an SLC 500 Data Table Access Module. It provides plant floor operator interface functions for SLC 500 modular and fixed controllers. Operators use the module to modify file information, alter CPU operating modes, and transfer memory. The unit also monitors, displays, and clears active processor faults. It connects directly to processors using dedicated serial interface cables.
The module features a sealed nineteen-key membrane keypad providing tactile feedback. A two-line dot matrix backlit liquid crystal display presents sixteen characters per line. Users can adjust screen contrast to maintain visibility across various ambient lighting environments. The hardware supports six selectable system languages for global plant integration. Factory defaults configure communication at nineteen point two kilobaud with node address zero.
TECHNICAL DATA
Technical Specifications
| Parameter | Specification |
|---|
| Product Line | SLC 500 |
|---|
| Weight | 2.00 lbs (0.91 kg) |
|---|
| Supported Functions | modify controller mode, monitor, clear and reset processor faults and memory transfer. |
|---|
| Supply Voltage | 12 Volts DC |
|---|
| Mounting Type | Panel Mount |
|---|
| Current Rating | 0.5 Amps |
|---|
| Display | LCD Monochrome Display with Back-Lighting |
|---|
| Operating Temperature | 0 to 55 degrees Celsius |
|---|
| UNSPSC | 43232608 |
|---|
| Ambient Relative Humidity | 5 to 95% |
|---|
| Product Lifecycle Status* | Discontinued/Obsolete |
|---|
| Backlight | LCD |
|---|
TECHNICAL INFORMATION
Features
- Offers monitor and modify operating modes for direct SLC 500 data table interaction.
- Features a backlit LCD display showing two lines of sixteen characters.
- Includes a nineteen-key sealed membrane keypad with tactile feedback.
- Permits viewing, clearing, and resetting of active SLC processor faults.
- Supports memory transfer and controller operating mode adjustments.
- Provides six selectable display languages including English, French, German, Italian, Spanish, and Japanese.
TECHNICAL INFORMATION
Applications
- Plant floor monitoring and diagnostics for SLC 500 controller installations.
- Operator data entry and setpoint adjustment without a personal computer.
- Clearing processor fault conditions directly at the machine enclosure.
TECHNICAL INFORMATION
Connections / Interfaces
- Connects to SLC 500 processors using the 1747-C10 interconnect cable.
- Interfaces with 1747-AIC link couplers via peripheral port J2.
- Connects to SLC 5/04 processors using a 1747-KE module and 1747-CP3 cable.
- Bridges to SLC 5/04 processors using 1747-AIC and 1761-NET-AIC via Belden 9842 cable.
TECHNICAL INFORMATION
Installation Guidelines
- Mount the unit securely into a panel cutout matching the rear enclosure dimensions.
- Provide adequate clearance for the 63.5 millimeter rear case depth.
- Maintain ambient operating temperatures between 0 and 55 degrees Celsius.
- Ensure enclosure humidity remains between 5 and 95 percent non-condensing.
TECHNICAL INFORMATION
Configuration Guidelines
- Factory default parameters assign DTAM node address to zero.
- Factory communication speed is preset to 19200 baud.
- Auto-Attach is disabled by default in factory settings.
- LCD backlighting is enabled by default for display visibility.
- Use the membrane keypad to alter default node address and communication settings.
TECHNICAL INFORMATION
Compatibility
- Compatible with Allen-Bradley SLC 500 fixed and modular hardware platforms.
- Does not support Floating Point, String, or ASCII data tables on SLC 5/03 OS301 or later.
- Requires the SLC 5/03 keyswitch in the REM position to alter operating modes.
TECHNICAL INFORMATION
Lifecycle / Replacement Information
- The 1747-DTAM module is classified as discontinued and obsolete by the manufacturer.
- Replacement units remain available through verified industrial surplus and refurbishment channels.
TECHNICAL RESOURCES
Documentation
COMPATIBILITY
Compatibility & Replacement
COMPATIBLE MODELSCompatible with Allen-Bradley SLC 500 fixed and modular hardware platforms. Does not support Floating Point, String, or ASCII data tables on SLC 5/03 OS301 or later. Requires the SLC 5/03 keyswitch in the REM position to alter operating modes.
Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.
PART VERIFICATION
Before You Order
Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.
01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS
From RFQ to Dispatch
1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ
Frequently Asked Questions
What is the primary function of the Allen-Bradley 1747-DTAM?
The module enables monitoring and modifying SLC 500 data tables, clearing faults, and changing processor operating modes.
Which data table formats are restricted on newer SLC 5/03 processors?
The module does not support Floating Point, String, or ASCII values on SLC 5/03 OS301 or later firmware.
What is the indicative market reference price for the 1747-DTAM?
Refurbished units have an indicative market reference price around $1,495 USD, not representing a final quotation.