PRODUCT INFORMATION
Product Overview
The Allen-Bradley 2711-K10G20L1 is a PanelView 1000 Grayscale/Keypad operator terminal within the PanelView series. It features a 10.1-inch monochrome grayscale screen with 640 by 480 pixel resolution. A stainless-steel membrane keypad contains numeric inputs, navigation controls, and sixteen function keys. The unit includes 1008 KB of non-volatile storage and 310 KB of runtime memory.
This operator terminal operates from an input voltage range between 18 and 32 Volts DC. Power consumption reaches 24 Watts maximum at 24 Volts DC nominal input. An integrated Ethernet port supports linear network topologies up to 100 meters. A secondary RS-232 serial port connects directly to external printing hardware for data logging.
TECHNICAL DATA
Technical Specifications
| Parameter | Specification |
|---|
| Product Line | Panelview 1000 |
|---|
| Weight | 9.38 lbs (4.25 kg) |
|---|
| Accessories | function key legend inserts; Anti-glare overlays; backlight replacements; Real-time clock replacements; Mounting hardware; Power supply and terminal block; interface modules; |
|---|
| Input Voltage range | 18-32VDC. |
|---|
| Communication ports | Ethernet I/P; RS232 (printer) |
|---|
| ATA memory card | Supported |
|---|
| Application memory | 310KB application runtime; 1008 KB nonvolatile memory (application objects plus text and bitmaps) |
|---|
| Backlight | 50,000 hr 1/2 life at 25 °C (77 °F) |
|---|
| Keypad function keys | 16 function keys (F1…F16) |
|---|
| Resolution | 640 x 480 |
|---|
| Display Area | 211 x 158 mm (8.3 x 6.2 in.) |
|---|
| Display Type | Black/white monochrome |
|---|
| Display Size | 10.1 in. |
|---|
| Display Color | Grayscale |
|---|
| Input Type | Keypad |
|---|
| Communication | Ethernet and Printer (RS-232) Port |
|---|
| Input Power | 24 Volts Direct Current |
|---|
| Memory | 256 Kilobytes |
|---|
| Enclosure Type | NEMA Type 12/13 or 4X |
|---|
| Product Lifecycle Status* | Discontinued/Obsolete |
|---|
TECHNICAL INFORMATION
Features
- Contains sixteen assignable function keys with a one-million actuation rating.
- Provides a 10.1-inch monochrome grayscale screen displaying 640 by 480 pixels.
- Operates on a nominal 24 Volt direct-current electrical input supply.
- Incorporates an integrated Ethernet port supporting linear industrial network architectures.
- Includes a dedicated RS-232 serial interface for printing process records.
- Supports ATA memory card expansion with capacities from 2 MB to 32 MB.
TECHNICAL INFORMATION
Applications
- Industrial machinery control and real-time operational status monitoring.
- Process parameter visualization and local recipe management using memory cards.
- Automated production alarm documentation using attached serial printers.
TECHNICAL INFORMATION
Connections / Interfaces
- One 10/100 Mbps Ethernet communication port supporting linear network links up to 100 meters.
- One RS-232 serial communication port reserved for external printer attachments.
- One ATA memory card slot for backup application files and recipe records.
TECHNICAL INFORMATION
Installation Guidelines
- Mount the operator terminal into an enclosure opening matching the outer faceplate dimensions.
- Ensure environmental operating temperatures stay between 0 and 55 degrees Celsius.
- Maintain non-condensing relative humidity levels between 5 percent and 95 percent.
- Supply clean direct-current electrical power between 18 and 32 Volts DC.
TECHNICAL INFORMATION
Configuration Guidelines
- Develop application logic and screen navigation using Rockwell Automation 2711-ND3 PanelBuilder32 software.
- Transfer compiled screen applications via linear Ethernet or an approved ATA memory card.
TECHNICAL INFORMATION
Compatibility
- Communicates across linear Ethernet architectures to compatible automation controllers.
- Configures using Rockwell Automation 2711-ND3 PanelBuilder32 editing software.
- Compatible with ATA memory cards ranging from 2 MB to 32 MB capacity.
TECHNICAL INFORMATION
Lifecycle / Replacement Information
- The 2711-K10G20L1 terminal carries discontinued and obsolete lifecycle status from the manufacturer.
- Operational production facilities source maintained spare units and replacement assemblies for plant support.
TECHNICAL INFORMATION
Compliance and Certifications
- NEMA Type 12
- NEMA Type 13
- NEMA Type 4X
- IP65
TECHNICAL RESOURCES
Documentation
COMPATIBILITY
Compatibility & Replacement
COMPATIBLE MODELSCommunicates across linear Ethernet architectures to compatible automation controllers. Configures using Rockwell Automation 2711-ND3 PanelBuilder32 editing software. Compatible with ATA memory cards ranging from 2 MB to 32 MB capacity.
Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.
PART VERIFICATION
Before You Order
Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.
01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS
From RFQ to Dispatch
1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ
Frequently Asked Questions
What communication interfaces are integrated into the 2711-K10G20L1 terminal?
The terminal includes an Ethernet communication port and an RS-232 serial port for external printer connections.
What are the electrical power input requirements for the 2711-K10G20L1?
This unit requires direct-current power between 18 and 32 Volts DC, consuming up to 24 Watts.
Which engineering software configures the 2711-K10G20L1 operator terminal?
Operators configure this terminal using Rockwell Automation 2711-ND3 PanelBuilder32 software.
What is the market pricing for the 2711-K10G20L1 operator terminal?
Observed figures represent indicative market reference pricing only and are not a final quotation.