HomeAllen-BradleyPanelViewStandard Logic ModuleAllen-Bradley 2711P-RP2 PanelView Standard Logic Module
Allen-Bradley•Standard Logic Module

Allen-Bradley 2711P-RP2 PanelView Standard Logic Module

Pricing
Request Pricing
Contact us for current price and availability.

The Allen-Bradley 2711P-RP2 is a standard logic module for the PanelView series. The unit operates within the PanelView Plus range from model 700 to model 1500. It is equipped with 128 MB of flash memory. The module also contains 128 MB of RAM capacity.

ManufacturerAllen-Bradley
Part Number2711P-RP2
Product TypeStandard Logic Module
ConditionNew
Warranty12 Months
AvailabilityRequest current stock
12-Month Warranty30-Day Return Request WindowGlobal Shipping Support
✓
12 Months WarrantyCommercial warranty confirmed with quotation.
↩
30-Day Return RequestEligible returns subject to authorization.
✈
Worldwide ShippingCourier and freight options for international orders.
#
Part Number VerificationSend a label photo when suffix or revision is uncertain.
PRODUCT INFORMATION

Product Overview

The Allen-Bradley 2711P-RP2 is a standard logic module for the PanelView series. The unit operates within the PanelView Plus range from model 700 to model 1500. It is equipped with 128 MB of flash memory. The module also contains 128 MB of RAM capacity.

The unit operates with a nominal input voltage rating of 24V DC. It accepts an input voltage range between 18V and 30V DC. Operating temperatures for this module range from 0 to 55 degrees Celsius. Storage capabilities extend from -25 to 70 degrees Celsius. The module functions at altitudes up to 2000 meters above sea level. It tolerates an operating shock limit of 15 G for 11 milliseconds.

TECHNICAL DATA

Technical Specifications

ParameterSpecification
UPC781180687266
Weight2.31 lbs (1.05 kg)
Input Voltage TypeDC Input
Memory TypesFlash and RAM
Flash Memory Capacity128 MB
RAM Capacity128 MB
Compatible Panelview Plus TerminalsPanelview Plus 700 to 1500 Terminals
Nominal Input Voltage Rating24V DC
Input Voltage Range18-30V DC
Operating Temperature0 to 55 degrees Celsius
Storage Temperature-25 to 70 degrees Celsius
Relative Humidity5 to 95% (non-condensing)
Maximum Operating Altitude2000 meters above sea level
Maximum Operating Shock15 G for 11 ms
Maximum Non-Operating Shock30 G for 11 ms
TECHNICAL INFORMATION

Features

  • Standard logic module for PanelView Plus 700 to 1500 terminals.
  • Equipped with 128 MB of flash memory.
  • Configured with 128 MB of RAM.
  • Accepts a nominal input voltage of 24V DC.
  • Operates over an input voltage span of 18V to 30V DC.
  • Functions at operating elevations up to 2000 meters above sea level.
  • Withstands non-operating shocks up to 30 G for 11 milliseconds.
TECHNICAL INFORMATION

Installation Guidelines

  1. Supply direct-current power within the approved range of 18V to 30V DC.
  2. Maintain operational ambient temperatures between 0 and 55 degrees Celsius.
  3. Ensure relative humidity remains between 5% and 95% without condensation.
  4. Operate the unit at elevations up to 2000 meters above sea level.
TECHNICAL INFORMATION

Compatibility

  • Compatible with PanelView Plus 700 terminals.
  • Compatible with PanelView Plus 1000 terminals.
  • Compatible with PanelView Plus 1250 terminals.
  • Compatible with PanelView Plus 1500 terminals.
COMPATIBILITY

Compatibility & Replacement

COMPATIBLE MODELSCompatible with PanelView Plus 700 terminals. Compatible with PanelView Plus 1000 terminals. Compatible with PanelView Plus 1250 terminals. Compatible with PanelView Plus 1500 terminals.

Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.

PART VERIFICATION

Before You Order

Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.

01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS

From RFQ to Dispatch

1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ

Frequently Asked Questions

Which graphic terminals are compatible with the 2711P-RP2 logic module?
The module is compatible with PanelView Plus 700, 1000, 1250, and 1500 terminals.
What memory capacity is provided on the 2711P-RP2?
The unit includes 128 MB of flash memory and 128 MB of RAM.
What are the input voltage requirements for the 2711P-RP2?
It requires a nominal 24V DC input and accommodates an 18V to 30V DC range.
What environmental conditions support module operation?
The module operates from 0 to 55 degrees Celsius in 5% to 95% non-condensing humidity.
Condition Confirmed Before OrderQuoted condition is confirmed before payment and dispatch.
Warranty & Returns12 Months standard warranty and 30-day return request period.International DeliveryShipping method is selected according to destination and shipment size.
Technical Source PolicySpecifications are published only when supported by product or manufacturer references.
NEED THIS PART?

2711P-RP2

Send the quantity and destination country. We will confirm stock, condition, price and lead time.

Get Product Updates and Stock Availability Alerts

    REQUEST A QUOTE

    Check Price & Availability

    ProductAllen-Bradley 2711P-RP2 PanelView Standard Logic Module
    Part Number: 2711P-RP2

      Request a Quote

      Send us the required quantity and destination. We will reply with current availability, lead time and final pricing.

      Home
      Products
      Account