PRODUCT INFORMATION
Product Overview
The Allen-Bradley 2711P-RP8DK is a DC-powered logic module for HMI terminals in the PanelView family. It operates on a nominal input voltage of 24 VDC with reverse polarity protection. The assembly integrates an isolated power supply design to protect against installation faults. This module incorporates 512 MB of non-volatile flash memory and 512 MB of RAM.
The unit features a conformal-coated printed circuit board assembly for enhanced environmental durability. It mounts directly into the display slot of compatible PanelView Plus 700 to 1500 terminals. Network communication includes an Auto-MDI/MDI-X 10/100 Mbps Ethernet port and an RS-232 serial interface. Additional connectivity provides one USB host port along with one USB device port for peripherals. Enclosure ratings meet NEMA 12, 13, and 4X, alongside IEC IP54 and IP65 standards.
TECHNICAL DATA
Technical Specifications
| Parameter | Specification |
|---|
| UPC | 612598876891 |
|---|
| Weight | 2.88 lbs (1.30 kg) |
|---|
| Memory | 512 MB flash, 512 MB RAM |
|---|
| Input Voltage | 24 VDC nominal |
|---|
| Power Consumption | 70 W max, 39 W typical |
|---|
| Power Design | Isolated 24 V DC, reverse polarity protected |
|---|
| Ethernet | 10/100 Mbps Auto-MDI/MDI-X |
|---|
| Serial | RS-232 port |
|---|
| USB | 1 host port, 1 device port |
|---|
| Display Support | PanelView Plus 700–1500 |
|---|
| Mounting | Embedded in display slot |
|---|
| Coating | Conformal-coated PCBA |
|---|
| Catalog Code | 8 = 512 MB, K = coating |
|---|
| Enclosure | NEMA 12/13/4X, IEC IP54/IP65 |
|---|
| Heat | 85–240 BTU/hr by size |
|---|
TECHNICAL INFORMATION
Features
- 512 MB non-volatile flash memory and 512 MB system RAM.
- Nominal 24 VDC input power with reverse polarity protection.
- Integrated 10/100 Mbps Ethernet port with Auto-MDI/MDI-X support.
- Dedicated RS-232 serial communication port.
- Dual USB configuration featuring one host port and one device port.
- Conformal-coated PCBA for protection in challenging operating environments.
- Direct display slot mounting for compact installation.
TECHNICAL INFORMATION
Applications
- Operator interface execution in PanelView Plus 6 industrial environments.
- Industrial machine control requiring conformal coating protection.
- Networked automation cells utilizing Ethernet and serial communications.
TECHNICAL INFORMATION
Connections / Interfaces
- One RJ45 10/100 Mbps Ethernet port supports Auto-MDI/MDI-X switching.
- One RS-232 serial interface allows direct serial industrial communications.
- One USB host port allows connection of external input devices or flash drives.
- One USB device port facilitates direct connection to host systems.
- Isolated DC power terminals accept nominal 24 VDC power wiring.
TECHNICAL INFORMATION
Installation Guidelines
- The unit embeds directly into the rear slot of the display unit.
- Verify correct nominal 24 VDC wiring polarity before energizing the module.
- Ensure adequate ventilation to dissipate between 85 and 240 BTU/hr of heat.
TECHNICAL INFORMATION
Configuration Guidelines
- Configure Ethernet network parameters via the PanelView system setup menus.
- Assign RS-232 serial baud rates and protocols according to connected controller settings.
TECHNICAL INFORMATION
Compatibility
- The module supports PanelView Plus 700 to 1500 display assemblies.
- It operates within the PanelView Plus 6 product line architecture.
TECHNICAL INFORMATION
Compliance and Certifications
- Enclosure ratings comply with NEMA 12, 13, and 4X standards.
- Ingress protection meets IEC IP54 and IP65 requirements.
COMPATIBILITY
Compatibility & Replacement
COMPATIBLE MODELSThe module supports PanelView Plus 700 to 1500 display assemblies. It operates within the PanelView Plus 6 product line architecture.
Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.
PART VERIFICATION
Before You Order
Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.
01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS
From RFQ to Dispatch
1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ
Frequently Asked Questions
What display terminals are compatible with the Allen-Bradley 2711P-RP8DK?
The 2711P-RP8DK embeds directly into PanelView Plus 700 through 1500 display assemblies.
What does the 2711P-RP8DK catalog code indicate?
The code 8 signifies 512 MB memory. The suffix K indicates a conformal-coated PCBA.
What are the power requirements for this logic module?
The module requires an isolated nominal 24 VDC power supply. Typical draw is 39 watts, with a 70-watt maximum.
What communication ports are available on the 2711P-RP8DK?
It includes an Auto-MDI/MDI-X 10/100 Mbps Ethernet port, an RS-232 port, and two USB ports.