The General Electric IC695ALG508 is an RTD Input Module for the PACSystems RX3i platform. It provides eight isolated differential channels for direct temperature sensing or linear resistance inputs. Supported RTD sensor elements include Platinum, Nickel, Copper, and Nickel-Iron. Wiring configurations accommodate 2-wire, 3-wire, or 4-wire sensors. Internal temperature linearization is formulated according to ITS-90 standards.

ManufacturerGeneral Electric
Part NumberIC695ALG508
Product TypeRTD Input Module
ConditionNew
Warranty12 Months
AvailabilityRequest current stock
12-Month Warranty30-Day Return Request WindowGlobal Shipping Support
✓
12 Months WarrantyCommercial warranty confirmed with quotation.
↩
30-Day Return RequestEligible returns subject to authorization.
✈
Worldwide ShippingCourier and freight options for international orders.
#
Part Number VerificationSend a label photo when suffix or revision is uncertain.
PRODUCT INFORMATION

Product Overview

The General Electric IC695ALG508 is an RTD Input Module for the PACSystems RX3i platform. It provides eight isolated differential channels for direct temperature sensing or linear resistance inputs. Supported RTD sensor elements include Platinum, Nickel, Copper, and Nickel-Iron. Wiring configurations accommodate 2-wire, 3-wire, or 4-wire sensors. Internal temperature linearization is formulated according to ITS-90 standards.

This module mounts directly into an RX3i universal backplane. It supports Removal and Insertion Under Power during routine maintenance. Internal power draws 400 mA at 3.3 VDC and 200 mA at 5.1 VDC. Field wiring connects using compatible box-style or spring-style terminal blocks. Extended terminal block versions provide extra depth for shielded wiring. Diagnostic LEDs show module operational status and external field power presence.

TECHNICAL DATA

Technical Specifications

ParameterSpecification
Weight1.31 lbs (0.60 kg)
Product DescriptionResistance Temperature Detector (RTD) Input module
Module TypeRTD Input Module
No of ChannelsEight (8), isolated, differential
Number of Inputs8 Differential Inputs
RTD Input types50, 100, 200, 500, and 1000 ohm Platinum 385 (IEC751 1983, Amend 2 1995; JISC 1604 1997); 50, 100, 200, 500, and 1000 ohm Platinum 391.6 (JISC 1604: 1981); 100 ohm, 200 ohm, 500 ohm, and 1000 ohm Nickel 618 (DIN 43760 Sept. 1987); 120 ohm Nickel 672 (MINCO Application Aid #18, 5/90 Type Ni); 10, 50, and 100 ohm Copper 426 (SAMA RC21-4-1966) and 604 ohm Nickel-Iron 518
Internal Power3.3V @ 400mA and 5.1V @ 200 mA
RTD Wiring2, 3, or 4 wire RTD types
Range (Ohms)250/500/1000/2000/3000/4000
Resistance inputs0-260, 0-525, 0-1050, 0-2100, 0-3150, 0-4200 ohms
Power Dissapation2.5W max
Measurement UnitsDegrees C or F, or Ohms
Operating Temperature0 to 60 degrees Celsius
Configurable notch filters2.3 Hz to 28 Hz
Storage Temperature-40 to 85 degrees Celsius
Hot-SwapSupports Removal and Insertion Under Power (RIUP)
Humidity5 to 95%, Non-condensing
Data Format16-bit integer (in a 32-bit field) or 32-bit real number data for each channel
Module Fault statusWatchdog, RAM Fail, Flash Fail
Current consumption3.3V: 400mA; 5V: 200mA
TECHNICAL INFORMATION

Features

  • Eight isolated differential channels configurable independently for RTD or resistance acquisition.
  • Supports Platinum 385, Platinum 391.6, Nickel 618, Nickel 672, Copper 426, and Nickel-Iron 518 sensor types.
  • Handles resistance ranges including 0 to 260, 525, 1050, 2100, 3150, and 4200 ohms.
  • Configurable notch filter frequency per channel from 2.3 Hz to 28 Hz.
  • Selectable data format in 16-bit integer or 32-bit IEEE floating-point values.
  • Configurable module reaction holding last state or defaulting on CPU stop or system fault.
  • Supports hot-swapping through Removal and Insertion Under Power capabilities.
TECHNICAL INFORMATION

Applications

  • PACSystems RX3i industrial temperature acquisition requiring high channel-to-channel isolation.
  • Direct interface to 2-wire, 3-wire, or 4-wire RTD temperature probes in process control.
  • Resistance measurement across broad ranges up to 4200 ohms without external signal conditioners.
TECHNICAL INFORMATION

Connections / Interfaces

  • Compatible with IC694TBB032 box-style terminal blocks.
  • Compatible with IC694TBB132 extended box-style terminal blocks.
  • Compatible with IC694TBS032 spring-style terminal blocks.
  • Compatible with IC694TBS132 extended spring-style terminal blocks.
TECHNICAL INFORMATION

Installation Guidelines

  1. Install the module into any available slot of an RX3i Universal Backplane.
  2. Extended terminal blocks are recommended when terminating shielded sensor wiring.
  3. Ensure terminal blocks are secured to the module face prior to system operation.
  4. Removal and insertion under power may be performed while the backplane is energized.
TECHNICAL INFORMATION

Configuration Guidelines

  1. Configure individual channels for specific RTD sensor curves or raw resistance ranges.
  2. Select engineering units in degrees Celsius, degrees Fahrenheit, or ohms.
  3. Set data reporting format to either 16-bit integer or 32-bit floating-point data.
  4. Adjust the programmable notch filter between 2.3 Hz and 28 Hz to reject process noise.
TECHNICAL INFORMATION

Compatibility

  • PACSystems RX3i Universal Backplane systems.
  • Terminal block assemblies IC694TBB032, IC694TBB132, IC694TBS032, and IC694TBS132.
COMPATIBILITY

Compatibility & Replacement

COMPATIBLE MODELSPACSystems RX3i Universal Backplane systems. Terminal block assemblies IC694TBB032, IC694TBB132, IC694TBS032, and IC694TBS132.

Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.

PART VERIFICATION

Before You Order

Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.

01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS

From RFQ to Dispatch

1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ

Frequently Asked Questions

How many RTD channels does the IC695ALG508 provide?
The IC695ALG508 features eight isolated differential input channels. Each channel can be configured independently for temperature or resistance sensors.
Which terminal blocks are compatible with the IC695ALG508?
It uses IC694TBB032, IC694TBB132, IC694TBS032, or IC694TBS132 terminal blocks. Extended versions provide additional depth for shielded cables.
Can the IC695ALG508 be replaced while the PACSystems RX3i backplane is powered?
Yes. The IC695ALG508 supports Removal and Insertion Under Power inside compatible PACSystems RX3i backplanes.
Condition Confirmed Before OrderQuoted condition is confirmed before payment and dispatch.
Warranty & Returns12 Months standard warranty and 30-day return request period.International DeliveryShipping method is selected according to destination and shipment size.
Technical Source PolicySpecifications are published only when supported by product or manufacturer references.
NEED THIS PART?

IC695ALG508

Send the quantity and destination country. We will confirm stock, condition, price and lead time.

Get Product Updates and Stock Availability Alerts

    REQUEST A QUOTE

    Check Price & Availability

    ProductGeneral Electric IC695ALG508 PACSystems RX3i RTD Input Module
    Part Number: IC695ALG508

      Request a Quote

      Send us the required quantity and destination. We will reply with current availability, lead time and final pricing.

      Home
      Products
      Account