The General Electric IC695PBM300 is a PROFIBUS Master Module designed for the PACSystems RX3i control platform. This single-slot module occupies a universal backplane location using the RX3i PCI bus interface. It enables the RX3i central processor to exchange cyclic and acyclic data across a standard PROFIBUS-DP network. Internal power consumption from the backplane is rated at 440 mA at 3.3 VDC.

ManufacturerGeneral Electric
Part NumberIC695PBM300
Product TypePROFIBUS Master Module
ConditionNew
Warranty12 Months
AvailabilityRequest current stock
12-Month Warranty30-Day Return Request WindowGlobal Shipping Support
✓
12 Months WarrantyCommercial warranty confirmed with quotation.
↩
30-Day Return RequestEligible returns subject to authorization.
✈
Worldwide ShippingCourier and freight options for international orders.
#
Part Number VerificationSend a label photo when suffix or revision is uncertain.
PRODUCT INFORMATION

Product Overview

The General Electric IC695PBM300 is a PROFIBUS Master Module designed for the PACSystems RX3i control platform. This single-slot module occupies a universal backplane location using the RX3i PCI bus interface. It enables the RX3i central processor to exchange cyclic and acyclic data across a standard PROFIBUS-DP network. Internal power consumption from the backplane is rated at 440 mA at 3.3 VDC.

This communication interface supports network management for up to 125 PROFIBUS-DP slave devices. The module accommodates up to 244 bytes of input data and 244 bytes of output data per slave. Total data exchange reaches up to 3584 bytes of input data and 3584 bytes of output data. Operating temperatures span from 0 to 60 degrees Celsius for industrial field installations.

TECHNICAL DATA

Technical Specifications

ParameterSpecification
Weight0.56 lbs (0.26 kg)
Product DescriptionProfibus Master Module
Communication interfaceOne (1) Profibus Master Port
Communication protocolProfiBus
CatalogIC695
No. of supported DP slave125
Input data244 Bytes
Number of Slots1 (single slot)
Output data244 Bytes
Backplane SupportUniversal
Baud rates9.6K, 19.2K, 93.75K, 187.5K, 500K, 1.5M, 3M, 6M and 12M Baud
Protocol SupportUp to 125 PROFIBUS-DP slaves
Mounting locationRX3i PCI
Communication PortsRS-232
Status informationSlave Status Bit Array table; Network diagnostic counters; DP master diagnostic counters; Slave Diagnostic Address
Internal Power at 3.3 V DC440 mA
Operating Temperature0 to 60 degrees Celsius
Backplane CompatibilityRX3i PCI
Current draw440 mA @ 3.3 VDC
Storage Temperature-40 to 85 degrees Celsius
Product Lifecycle StatusActive
TECHNICAL INFORMATION

Features

  • Connects up to 125 PROFIBUS-DP slave devices on a single network segment.
  • Handles up to 3584 bytes of total input data and 3584 bytes of total output data.
  • Allows 244 bytes of input data and 244 bytes of output data per connected slave.
  • Supports transmission rates from 9.6 kBit/s up to 12 MBit/s.
  • Provides DP-V1 read, write, and alarm messaging capabilities.
  • Includes sync and freeze operating modes for synchronized slave control.
  • Delivers diagnostic counters for network operations, DP master functions, and slave address status.
  • Features front-panel LED indicators for network state, module operation, and PROFIBUS OK status.
TECHNICAL INFORMATION

Applications

  • PACSystems RX3i distributed automation architectures utilizing fieldbus instrumentation.
  • Centralized integration of third-party PROFIBUS-DP motor drives, field sensors, and valve islands.
  • Process control installations requiring high-speed data exchange with cyclic and acyclic telemetry.
TECHNICAL INFORMATION

Connections / Interfaces

  • One 9-pin Sub-D connector for PROFIBUS-DP network bus cable integration.
  • One RS-232 serial communication port.
  • Direct RX3i PCI edge connection for communication across the universal backplane.
TECHNICAL INFORMATION

Installation Guidelines

  1. Install the module into any available PCI slot within an RX3i universal backplane.
  2. Maintain ambient operational temperatures between 0 and 60 degrees Celsius.
  3. Secure fieldbus wiring to the 9-pin Sub-D connector to prevent communication dropouts.
TECHNICAL INFORMATION

Configuration Guidelines

  1. Configure the master module using Machine Edition SP2 Logic Developer PLC software version 5.0 or later.
  2. Verify the host PACSystems RX3i CPU operates on firmware version 2.9 or higher.
  3. Transfer field firmware updates via the host controller utilizing the WinLoader software utility.
TECHNICAL INFORMATION

Compatibility

  • PACSystems RX3i universal backplanes with PCI support.
  • PACSystems RX3i CPU units with firmware version 2.9 or later.
  • Standard PROFIBUS-DP and DP-V1 compliant slave devices.
COMPATIBILITY

Compatibility & Replacement

COMPATIBLE MODELSPACSystems RX3i universal backplanes with PCI support. PACSystems RX3i CPU units with firmware version 2.9 or later. Standard PROFIBUS-DP and DP-V1 compliant slave devices.

Verify compatibility against the exact Part Number, revision and manufacturer documentation before ordering.

PART VERIFICATION

Before You Order

Industrial automation parts can share similar model names, suffixes and revisions. Confirm the complete manufacturer Part Number before purchase.

01Check Part NumberMatch the complete ordering code on the existing unit.
02Confirm RevisionCheck suffix, hardware or firmware when applicable.
03Send a Label PhotoWe can review a clear label photo when identification is uncertain.
ORDERING PROCESS

From RFQ to Dispatch

1Submit Part Number2Verify Product Identity3Confirm Stock & Condition4Issue Quotation5Dispatch & Tracking
PRODUCT FAQ

Frequently Asked Questions

What is the primary function of the IC695PBM300 module?
The IC695PBM300 functions as a PROFIBUS-DP master module for the PACSystems RX3i controller platform.
How many slave devices can the IC695PBM300 support?
The module supports up to 125 PROFIBUS-DP slave devices across the fieldbus network.
What controller firmware is required to operate the IC695PBM300?
The host PACSystems RX3i CPU requires firmware version 2.9 or later.
Condition Confirmed Before OrderQuoted condition is confirmed before payment and dispatch.
Warranty & Returns12 Months standard warranty and 30-day return request period.International DeliveryShipping method is selected according to destination and shipment size.
Technical Source PolicySpecifications are published only when supported by product or manufacturer references.
NEED THIS PART?

IC695PBM300

Send the quantity and destination country. We will confirm stock, condition, price and lead time.

Get Product Updates and Stock Availability Alerts

    REQUEST A QUOTE

    Check Price & Availability

    ProductGeneral Electric IC695PBM300 PACSystems RX3i PROFIBUS Master Module
    Part Number: IC695PBM300

      Request a Quote

      Send us the required quantity and destination. We will reply with current availability, lead time and final pricing.

      Home
      Products
      Account